module XPSAXE - stop and switch monitoring - 24 V DC/AC

Manufactured by:
Schneider Electric
Schneider%20electric

F8596bcd4ed3e8ceea367fe71f9b43584a57fb13 medium
Price (VAT excluded)
€ 219.02
Nuova Elva code
XPSAXE5120P
Manufacturer code
XPSAXE5120P
Availability
Send request for quotation

This XPSAXE safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. 24V AC/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It has removable terminals for easier and better control wires tightening, thus improving installation reliability.

Specifications

CertificationsBG
Net Weight0.229 kg
Operating Temperature-25-55 °C
StandardEN 1088/ISO 14119
Storage Temperature-25-75 °C
Warranty Length18 months

Specifications

[Us] Rated Supply Voltage24 V DC - 15...10 % || 24 V AC
Safety Levelcan reach PL e/category 4 EN/ISO 13849-1 || can reach SILCL 3 EN/IEC 62061
Range Of ProductPreventa Safety automation
Product Or Component TypePreventa safety module
Safety Module NameXPSAXE
Output Typerelay instantaneous opening, 3 NO, volt-free
Connections - Terminalscaptive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end || captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end || captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel || captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel || captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable end || captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² flexible without cable end || captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel
Number Of Additional Circuits1 NC
Safety Module Applicationfor emergency stop and switch monitoring
Safety Reliability DataDC > 99 % EN/ISO 13849-1 || MTTFd = 457 years EN/ISO 13849-1 || PFHd = 3E-8 1/h EN/IEC 62061

Contractual warranty

Warranty18 months

Complementary

[Uc] Control Circuit Voltage24 V DC
Local Signalling2 LEDs
Synchronisation Time Between Inputs< 0.5 s
Breaking Capacity1.5 A 24 V DC-13)50 ms relay output
Maximum Power Consumption In Va4 VA DC
Supply Frequency50/60 Hz
Maximum Response Time On Input Open80 ms
Breaking Capacity3600 VA inrush AC-15 B300 relay output || 360 VA holding AC-15 B300 relay output
Mounting Support35 mm symmetrical DIN rail
Output Thermal Current6 A instantaneous and time delay outputs
Minimum Output Voltage17 V relay output
Minimum Output Current10 mA relay output
Associated Fuse Rating6 A gG instantaneous outputs
[Uimp] Rated Impulse Withstand Voltage4 kV III IEC 60947-5-1 || 4 kV III DIN VDE 0110 part 1
Net Weight0.229 kg
[Ui] Rated Insulation Voltage300 V 2)IEC 60947-5-1 || 300 V 2)DIN VDE 0110 part 1

Offer Sustainability

Rohs Exemption InformationYes
China Rohs RegulationX
Circularity ProfileENVEOLI1406024EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Mercury FreeYes
Environmental DisclosureENVPEP1406024EN
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Toxic Heavy Metal FreeYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.

Environment

Product CertificationsUL || BG || CSA
Ambient Air Temperature For Operation-25-55 °C
StandardsEN/IEC 60947-5-1 || EN/IEC 60204-1 || EN/ISO 13850 || EN 1088/ISO 14119
Ip Degree Of ProtectionIP20EN/IEC 60529 || IP40EN/IEC 60529
Ambient Air Temperature For Storage-25-75 °C

Docs