Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Master for hand protection, Hp = 460 mm, R=30 mm

Manufactured by:
Schneider Electric
Schneider electric

93478e6e1bcd130995ff6ac78f0147d64b5c97af medium
Price (VAT excluded)
€ 1279.58
Nuova Elva code
XUSL4E30H046NM
Manufacturer code
XUSL4E30H046NM
Availability
Send request for quotation

Specifications

CertificationsCE
Current42 mA
MaterialAluminium Casing
Net Weight1.02 kg
Output Voltage24 V
Storage Temperature-13-158 °F
Warranty Length18 months

Specifications

Minimum Object Diameter For Detection30 mm
Device Short NameXUSL4E
Type Of Startmanual || automatic
Range Of ProductTelemecanique Safety light curtains XUSL
Height Protected460 mm
Control Typeselected by wiring
Product Specific Applicationfor hand protection
Number Of Beams16
Product Or Component Typesafety light curtain type 4
[Sn] Nominal Sensing Distance0-12 m by cabling || 0-4 m by cabling
Output Type2 safety outputs OSSD solid-state PNP arc suppression)

Contractual warranty

Warranty18 months

Complementary

Electrical Connection1 male connector M12 5 pins transmitter || 1 male connector M12 8 pins receiver
EmissionIR LED 950 nm
Output Voltage24 V
Detection Systemtransmitter-receiver system
Maximum Voltage Drop<0.5 V
Topologydaisy chain master
MarkingCE
Output Current Limits0.4 A safety outputs OSSD
Supplypower supply IEC 61496-1 || power supply IEC 60204-1
Output Circuit TypeDC
[Eaa] Effective Aperture Angle2.5 ° at 3 m
Function Availabletest || muting through external safety module XPSLCMUT1160 || LED display of operating modes and faults
Net Weight1.02 kg
Local Signalling1 multi-colour LED transmitter || 2 dual colour LEDs receiver
[Us] Rated Supply Voltage24 V DC +/- 20 %
Current Consumption42 mA no-load transmitter || 83 mA no-load receiver || 42 mA transmitter || 900 mA with maximum load receiver
Housing Colourred RAL 3000
Offer Typestandard distance
Fixing Modeby fixing brackets
Materialaluminium casing || polycarbonate front panel || polypropylene end caps
[Ie] Rated Operational Current2 A
Kit Compositionadjustable mounting bracket(s) || 1 receiver(s) || 1 transmitter(s) || 1 user guide with certificate of conformity on CD-ROM

Offer Sustainability

Circularity ProfileENVEOLI1406015EN
Reach Free Of SvhcYes
Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP1406015EN
Sustainable Offer StatusGreen Premium product
Toxic Heavy Metal FreeYes
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Reach RegulationFree of Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product CertificationsCE || TÜV || cULus
Vibration Resistance0.35 +/- 0.05 mm 10-55 Hz)IEC 61496-1
Ip Degree Of ProtectionIP65 || IP67
Safety Leveltype 4 IEC 61496-1 || SIL 3 IEC 61508 || SILCL 3 IEC 62061 || category 4 EN/ISO 13849-1 || PL = e EN/ISO 13849-1
Ambient Air Temperature For Operation-30-55 °C || 14-131 °F
Directives89/336/EEC - electromagnetic compatibility || 98/37/EEC - machinery || 89/655/EEC - work equipment
Ambient Air Temperature For Storage-13-158 °F || -35-70 °C
Service Life20 year(s)
Relative Humidity0-95 % without condensation
Safety Reliability DataPFHd = 9.47E-9 1/h IEC 61508
Shock Resistance10 gn 16 ms IEC 61496-1
Environmental Characteristicresistance to light disturbance EN/IEC 61496-2

Docs


Similar items