Ultrasonic sensors XX, ultrasonic sensor cylindrical m18 12, 24 V
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 232.07
- Nuova Elva code
- XX318AU08EKAM12
- Manufacturer code
- XX318AU08EKAM12
- Availability
- Send request for quotation
Specifications
Certifications | CCSAus |
---|---|
Current | 100 mA |
Depth | 95.5 mm |
Enclosure Material | PEI |
Height | 18 mm |
Material | Plastic |
Standard | IEC 60947-5-2 |
Storage Temperature | -40-80 °C |
Thread Type | M18 X 1 |
Width | 18 mm |
Specifications | |
[Us] Rated Supply Voltage | 12...24 V DC reverse polarity protection |
Electrical Connection | male connector M12 4 pins |
Sensor Design | cylindrical M18 |
Sensor Name | XX3 |
[Sn] Nominal Sensing Distance | 0.0381-0.0381 m fixed |
[Sd] Sensing Range | 0.038-0.0508 m |
Material | plastic |
Wiring Technique | 4-wire |
Ip Degree Of Protection | IP67 conforming to IEC 60529 |
Series Name | general purpose |
Discrete Output Type | PNP/NPN |
Beam Angle | 10 ° |
Discrete Output Function | 1 NO |
Type Of Output Signal | discrete |
Range Of Product | Telemecanique Ultrasonic sensors XX |
Detection System | diffuse |
Sensor Type | ultrasonic sensor |
Complementary | |
Thread Type | M18 x 1 |
Supply Voltage Limits | 10-28 V DC |
[Sa] Assured Operating Distance | 0.038-0.0508 m |
Enclosure Material | PEI |
Marking | CE |
Width | 18 mm |
Front Material | silicone |
Depth | 95.5 mm |
Blind Zone | 0-31.8 mm |
Current Consumption | 100 mA |
Maximum Differential Travel | 12.7 mm |
Height | 18 mm |
Maximum Switching Current | 100 mA overload and short-circuit protection |
Minimum Size Of Detected Object | cylinder diameter 50.8 mm 4.732 m |
Maximum Delay Response | 1.5 ms |
Maximum Delay Recovery | 1.5 ms |
Maximum Delay First Up | 20 ms |
Maximum Voltage Drop | 1 V |
Status Led | supply on 1 LED green) || output state 1 LED amber) |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Environment | |
Product Certifications | UL || cCSAus |
Ambient Air Temperature For Operation | 0-50 °C |
Resistance To Electromagnetic Fields | 10 V/m level 3 IEC 61000-4-3 |
Ambient Air Temperature For Storage | -40-80 °C |
Standards | IEC 60947-5-2 |
Resistance To Electrostatic Discharge | 8 kV level 4 IEC 61000-4-2 |
Vibration Resistance | +/-1 mm 10-55 Hz)IEC 60068-2-6 |
Shock Resistance | 30 gn in all 3 axes 11 ms IEC 60068-2-27 |
Resistance To Fast Transients | 1 kV level 3 IEC 61000-4-4 |