Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CE, RH side -2NC, booted pushbutton
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 220.05
- Nuova Elva code
- XY2CE1A270H7
- Manufacturer code
- XY2CE1A270H7
- Availability
- Send request for quotation
This XY2CE Emergency Stop Rope pull Switch is designed with a right hand side anchor point, allowing operator to trigger the stop of potentially dangerous machines at any point of its working area. It operates with a maximum rope length of 70 meters. It has a Zamak body with a booted pushbutton reset, Nitrile bellows, no pilot light, and 2 normally closed slow break contacts. Its B10D reliability data is 300 000. This emergency stop rope pull switch is suitable for woodworking machines, shears, conveyor systems, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works, etc. Its IP66 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-5, EN/ISO 13850, UL NISD, CSA C22.2 No 14-13 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Specifications
Certifications | CCC |
---|---|
Net Weight | 1.45 kg |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Specifications | |
Housing Colour | red RAL 3000 |
Range Of Product | Telemecanique Emergency stop rope pull switches XY2C |
Overvoltage Category | class I EN/IEC 61140 || class I NF C 20-030 |
Product Or Component Type | latching emergency stop rope pull switch |
Device Short Name | XY2CE |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Trigger Cable Maximum Length | 70 m |
Contact Operation | slow-break |
Distance Between Cable Supports | 5-5 m |
Mechanical Durability | 60000 cycles |
Positive Opening | with EN/IEC 60947-5-1 |
Cable Entry Number | 3 tapped entry 1/2" NPT conduit entry |
Compatibility Code | XY2CE |
Body Material | zamak |
[Ithe] Conventional Enclosed Thermal Current | 10 A |
Trigger Cable Anchor Point | RH side |
Safety Reliability Data | B10d = 300000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5 |
Connections - Terminals | screw clamp terminal, 1 x 0.5...2 x 1.5 mm² |
Marking | CE |
Cover Material | stainless steel |
Local Signalling | without pilot light |
Net Weight | 1.45 kg |
Tightening Torque | 0.8-1.2 N.m |
[Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-1 |
Maximum Resistance Across Terminals | 25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A |
Safety Level | can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Reset | by booted push-button |
Contacts Type And Composition | 2 NC |
Number Of Cables | 1 |
Terminals Description Iso N°1 | (21-22)NC || (11-22)NC |
[Ui] Rated Insulation Voltage | 500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14 |
Short-Circuit Protection | 10 A cartridge fuse gG EN/IEC 60269 |
[Ie] Rated Operational Current | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP111159EN |
Sustainable Offer Status | Green Premium product |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Environment | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Standards | EN/IEC 60947-5-5 || UL 508 || EN/ISO 13850 || work equipment directive 2009/104/EC || EN/IEC 60204-1 || machinery directive 2006/42/EC || EN/IEC 60947-5-1 || CSA C22.2 No 14 |
Product Certifications | UL category NISD emergency stop devices || CSA || CCC |
Shock Resistance | 50 gn 11 ms EN/IEC 60068-2-27 |
Vibration Resistance | 10 gn 10-300 Hz)EN/IEC 60068-2-6 |
Protective Treatment | TC |
Ip Degree Of Protection | IP66 IEC 60529 |