Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CE, RH side -2NC, booted pushbutton

Manufactured by:
Schneider Electric
Schneider electric

62a8cfb54a389e563e7aa419e284804fcf7be49f medium
Price (VAT excluded)
€ 220.05
Nuova Elva code
XY2CE1A270H7
Manufacturer code
XY2CE1A270H7
Availability
Send request for quotation

This XY2CE Emergency Stop Rope pull Switch is designed with a right hand side anchor point, allowing operator to trigger the stop of potentially dangerous machines at any point of its working area. It operates with a maximum rope length of 70 meters. It has a Zamak body with a booted pushbutton reset, Nitrile bellows, no pilot light, and 2 normally closed slow break contacts. Its B10D reliability data is 300 000. This emergency stop rope pull switch is suitable for woodworking machines, shears, conveyor systems, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works, etc. Its IP66 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-5, EN/ISO 13850, UL NISD, CSA C22.2 No 14-13 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.

Specifications

CertificationsCCC
Net Weight1.45 kg
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months

Specifications

Housing Colourred RAL 3000
Range Of ProductTelemecanique Emergency stop rope pull switches XY2C
Overvoltage Categoryclass I EN/IEC 61140 || class I NF C 20-030
Product Or Component Typelatching emergency stop rope pull switch
Device Short NameXY2CE

Contractual warranty

Warranty18 months

Complementary

Trigger Cable Maximum Length70 m
Contact Operationslow-break
Distance Between Cable Supports5-5 m
Mechanical Durability60000 cycles
Positive Openingwith EN/IEC 60947-5-1
Cable Entry Number3 tapped entry 1/2" NPT conduit entry
Compatibility CodeXY2CE
Body Materialzamak
[Ithe] Conventional Enclosed Thermal Current10 A
Trigger Cable Anchor PointRH side
Safety Reliability DataB10d = 300000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Connections - Terminalsscrew clamp terminal, 1 x 0.5...2 x 1.5 mm²
MarkingCE
Cover Materialstainless steel
Local Signallingwithout pilot light
Net Weight1.45 kg
Tightening Torque0.8-1.2 N.m
[Uimp] Rated Impulse Withstand Voltage6 kV EN/IEC 60947-1
Maximum Resistance Across Terminals25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Safety Levelcan reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Resetby booted push-button
Contacts Type And Composition2 NC
Number Of Cables1
Terminals Description Iso N°1(21-22)NC || (11-22)NC
[Ui] Rated Insulation Voltage500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
Short-Circuit Protection10 A cartridge fuse gG EN/IEC 60269
[Ie] Rated Operational Current3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP111159EN
Sustainable Offer StatusGreen Premium product
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-70 °C
StandardsEN/IEC 60947-5-5 || UL 508 || EN/ISO 13850 || work equipment directive 2009/104/EC || EN/IEC 60204-1 || machinery directive 2006/42/EC || EN/IEC 60947-5-1 || CSA C22.2 No 14
Product CertificationsUL category NISD emergency stop devices || CSA || CCC
Shock Resistance50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance10 gn 10-300 Hz)EN/IEC 60068-2-6
Protective TreatmentTC
Ip Degree Of ProtectionIP66 IEC 60529

Docs


Other Schneider Electric items

Request a quote