Simple emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CE, LH side, 1NC+1 NO
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 210.20
- Nuova Elva code
- XY2CE4A010
- Manufacturer code
- XY2CE4A010
- Availability
- Send request for quotation
This product is part of the XY2C range, an offer of emergency stop rope pull switches. This emergency stop rope pull switch has 1 normally closed + 1 normally opened, snap action contacts with positive opening operation. It is a switch with a rated operational current of 0.27A at 250V AC, 3A at 240V AC and a conventional enclosed thermal current of 10A. It is furnished with screw clamp terminals for electrical connection and 3 plain hole for PG13.5 or ISO M20 cable gland. The trigger cable anchor point at left hand side. It offers long mechanical durability which is about 60000 operating cycles. It is an IP66 rated product. The casing is made of Zamak (blue) with stainless steel cover. It is intended for all machine applications like woodworking machines, shears, conveyor systems, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works, etc. This product is certified by CSA. It meets EN/IEC 60947-5-1 standards. These emergency stop rope pull switches can be equipped with trip indicators, cable tension adjustment can be performed using a turnbuckle. The emergency stop rope pull switch is intended for all machines requiring stopping of dangerous movement in the immediate vicinity of the machine. The emergency stop rope pull switch is designed to avert hazards (dangerous phenomena) at the earliest possible moment or to reduce risks which could cause injury to persons or damage either to machines or work in progress.
Specifications
Certifications | CSA |
---|---|
Standard | EN/IEC 60947-5-1 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Specifications | |
Range Of Product | Telemecanique Emergency stop rope pull switches XY2C |
Product Or Component Type | simple stop rope pull switch |
Housing Colour | blue |
Overvoltage Category | class I EN/IEC 61140 || class I NF C 20-030 |
Device Short Name | XY2CE |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Reset | without |
Connections - Terminals | screw clamp terminal, 1 x 0.5...2 x 1.5 mm² |
Contacts Type And Composition | 1 NC + 1 NO |
[Ui] Rated Insulation Voltage | 500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14 |
[Ie] Rated Operational Current | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A |
Contact Operation | snap action |
Distance Between Cable Supports | 5-5 m |
Mechanical Durability | 60000 cycles |
Cable Entry Number | 3 plain hole Pg 13.5 or ISO M20 cable gland |
Compatibility Code | XY2CE |
Body Material | zamak |
Number Of Cables | 1 |
Trigger Cable Anchor Point | LH side |
Cover Material | stainless steel |
Tightening Torque | 0.8-1.2 N.m |
Maximum Resistance Across Terminals | 25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A |
Short-Circuit Protection | 10 A cartridge fuse gG EN/IEC 60269 |
Positive Opening | with EN/IEC 60947-5-1 |
[Ithe] Conventional Enclosed Thermal Current | 10 A |
Marking | CE |
Local Signalling | without pilot light |
[Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-1 |
Trigger Cable Maximum Length | 50 m |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP111159EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Ambient Air Temperature For Operation | -25-70 °C |
Standards | EN/IEC 60947-5-1 |
Product Certifications | CSA |
Shock Resistance | 50 gn 11 ms EN/IEC 60068-2-27 |
Vibration Resistance | 10 gn 10-300 Hz)EN/IEC 60068-2-6 |
Ip Degree Of Protection | IP66 IEC 60529 |
Ambient Air Temperature For Storage | -40-70 °C |
Protective Treatment | TC |