This product is part of the XY2C range, an offer of emergency stop rope pull switches. This dual emergency stop rope pull switch has 2 x (1 normally closed + 1 normally opened) slow-break contacts with positive opening operation. It is a switch with a rated operational current of 0.27A at 250V AC, 3A at 240V AC and a conventional enclosed thermal current of 10A. It is furnished with screw clamp terminals for electrical connection and 3 tapped entry for 1/2inch NPT conduit entry. The trigger cable anchor point at left hand and right hand side. It can reset by flush pushbutton. It offers long mechanical durability which is about 60000 operating cycles. It is an IP66 rated product. The casing is made of Zamak (red) with stainless steel cover. Its dimensions are 327mm (Width) x 106mm (Depth) x 142mm (Height) and weighs 1.9kg. It is intended for all machine applications like woodworking machines, shears, conveyor systems, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works, etc. This product is certified by CCC, CSA, EAC and UL. It meets CSA C22.2 No 14, EN/ISO 13850, EN/IEC 60947-5-1, EN/IEC 60204-1, EN/IEC 60947-5-5, UL 508 Machinery directive 2006/42/EC and Work equipment directive 2009/104/EC standards. These emergency stop rope pull switches can be equipped with trip indicators and double anchor points. The emergency stop rope pull switch is intended for all machines requiring stopping of dangerous movement in the immediate vicinity of the machine. These emergency stop rope pull switches are essential in premises and on machines that pose a potential hazard during operation. Operators must be able to activate the emergency stop from any point within their work area.

Specifications

CertificationsCCC
Net Weight1.9 kg
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C

Specifications

Range Of ProductTelemecanique Emergency stop rope pull switches XY2C
Product Or Component Typedual emergency stop rope pull switch
Housing Colourred RAL 3000
Overvoltage Categoryclass I EN/IEC 61140
Device Short NameXY2CED

Complementary

Resetby flush push-button
Net Weight1.9 kg
[Uimp] Rated Impulse Withstand Voltage6 kV EN/IEC 60947-1
Trigger Cable Maximum Length2 x 100 m
Connections - Terminalsscrew clamp terminal, 1 x 0.5...2 x 1.5 mm²
Contacts Type And Composition2 x (1 NC + 1 NO)
[Ui] Rated Insulation Voltage500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
[Ie] Rated Operational Current3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Contact Operationslow-break
Distance Between Cable Supports3-5 m
Mechanical Durability60000 cycles
Number Of Cables2
Cable Entry Number3 tapped entry 1/2" NPT conduit entry
Compatibility CodeXY2CED
Body Materialzamak
Trigger Cable Anchor PointRH and LH sides
Safety Reliability DataB10d = 300000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Cover Materialstainless steel
Tightening Torque0.8-1.2 N.m
Maximum Resistance Across Terminals25 MOhm EN/IEC 60255-7 category 3
Safety Levelcan reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Terminals Description Iso N°1(13-14)NO || (21-22)NC
Short-Circuit Protection10 A cartridge fuse gG EN/IEC 60269
Bellow Materialnitril
Positive Openingwith EN/IEC 60947-5-1
[Ithe] Conventional Enclosed Thermal Current10 A
MarkingCE
Local Signallingwith pilot light, red, 24...130 V

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP111159EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Ambient Air Temperature For Operation-25-70 °C
StandardsEN/ISO 13850 || EN/IEC 60947-5-1 || CSA C22.2 No 14 || machinery directive 2006/42/EC || EN/IEC 60204-1 || UL 508 || work equipment directive 2009/104/EC || EN/IEC 60947-5-5
Product CertificationsUL category NISD emergency stop devices || CSA || CCC || EAC
Shock Resistance50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance10 gn 10-300 Hz)EN/IEC 60068-2-6
Ip Degree Of ProtectionIP66 IEC 60529
Ambient Air Temperature For Storage-40-70 °C
Protective TreatmentTC