Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CH, 1NC+1 NO, pilot light 24 V, booted pushbutton
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 122.54
- Nuova Elva code
- XY2CH13253
- Manufacturer code
- XY2CH13253
- Availability
- Send request for quotation
This product is part of the XY2C range, an offer of emergency stop rope pull switches. This emergency stop rope pull switch has 1 NC and 1 NO, slow break contacts with the positive opening operation. The switch with a rated operating current of 3A at 240V AC, 0.27A at 250V DC and conventional enclosed thermal current of 10A. It is furnished with screw clamp terminals for electrical connection and 3 tapped entries for PG13.5 cable gland. The trigger cable anchor point at right or left hand sides. It offers long mechanical durability of about 8,00,000 operating cycles. It is an IP65 rated product. The casing is made of Zamak (red) with stainless steel cover. It weighs 0.865kg. It is suitable for woodworking machines, conveyor systems, printing machines, textile machines, rolling mills, test laboratories and surface treatment works. This product is certified by CE and UL. It meets EN/ISO 13850, EN/IEC 60947-5-1, EN/IEC 60947-5-5 and EN/IEC 60204-1 standards. The XY2 line of switches come in a robust metal enclosure so they can be used in severe environments and they conform to EN/ISO 13850 and EN/IEC 60947-5-5. XY2 range emergency stop rope pull switch is intended for all machines requiring stopping of a dangerous movement in the immediate vicinity of the machine.
Specifications
Certifications | UL Category NISD Emergency Stop Devices |
---|---|
Net Weight | 0.865 kg |
Standard | EN/IEC 60204-1 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Specifications | |
Range Of Product | Telemecanique Emergency stop rope pull switches XY2C |
Product Or Component Type | latching emergency stop rope pull switch |
Housing Colour | red RAL 3000 |
Overvoltage Category | class I EN/IEC 61140 || class I NF C 20-030 |
Device Short Name | XY2CH |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Reset | by booted push-button |
Net Weight | 0.865 kg |
[Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-1 |
Trigger Cable Maximum Length | 30 m |
Connections - Terminals | screw clamp terminal, 1 x 0.5...2 x 1.5 mm² |
Contacts Type And Composition | 1 NC + 1 NO |
[Us] Rated Supply Voltage | 24 V AC/DC |
[Ui] Rated Insulation Voltage | 500 V 3)EN/IEC 60947-1 || 300 VUL 508 |
[Ie] Rated Operational Current | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A |
Contact Operation | slow-break |
Distance Between Cable Supports | 5-5 m |
Number Of Cables | 1 |
Mechanical Durability | 800000 cycles |
Cable Entry Number | 3 tapped entry Pg 13.5 cable gland |
Compatibility Code | XY2CH |
Body Material | zamak |
Trigger Cable Anchor Point | RH or LH side |
Safety Reliability Data | B10d = 4000000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5 |
Cover Material | stainless steel |
Tightening Torque | 0.8-1.2 N.m |
Maximum Resistance Across Terminals | 25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A |
Safety Level | can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Terminals Description Iso N°1 | (13-14)NO || (21-22)NC |
Short-Circuit Protection | 10 A cartridge fuse gG EN/IEC 60269 |
Positive Opening | with EN/IEC 60947-5-1 |
Light Block Supply | direct |
[Ithe] Conventional Enclosed Thermal Current | 10 A |
Marking | CE |
Local Signalling | with pilot light, yellow, 24 V |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP111159EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Ambient Air Temperature For Operation | -25-70 °C |
Standards | machinery directive 2006/42/EC || EN/IEC 60947-5-5 || EN/ISO 13850 || work equipment directive 2009/104/EC || EN/IEC 60947-5-1 || EN/IEC 60204-1 |
Product Certifications | UL category NISD emergency stop devices |
Shock Resistance | 50 gn 11 ms EN/IEC 60068-2-27 |
Vibration Resistance | 10 gn 10-150 Hz)EN/IEC 60068-2-6 |
Ip Degree Of Protection | IP65 IEC 60529 |
Ambient Air Temperature For Storage | -40-70 °C |
Protective Treatment | TC |