Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CH, 1NC+1 NO, key release pushbutton

Manufactured by:
Schneider Electric
Schneider electric

6763b5fb2e61ede864a4f0752106fa42937ce27b medium
Price (VAT excluded)
€ 114.89
Nuova Elva code
XY2CH13450
Manufacturer code
XY2CH13450
Availability
Send request for quotation

This product is part of the XY2C range, an offer of emergency stop rope pull switches. This emergency stop rope pull switch has 1 normally closed + 1 normally opened, slow-break contacts with positive opening operation. It is a switch with a rated operational current of 0.27A at 250V AC, 3A at 240V AC and a conventional enclosed thermal current of 10A. It is furnished with screw clamp terminals for electrical connection and 3 tapped entry for PG13.5 cable gland. The trigger cable anchor point at left hand and right hand side. It can reset by key-release pushbutton. It offers long mechanical durability which is about 800000 operating cycles. It is an IP65 rated product. The casing is made of Zamak (red) with stainless steel cover. Its dimensions are 68mm (Width) x 95mm (Depth) x 201mm (Height) and weighs 0.91kg. It is intended for all machine applications like woodworking machines, shears, conveyor systems, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works, etc. This product is certified by CCC and UL. It meets EN/ISO 13850, EN/IEC 60947-5-1, EN/IEC 60204-1, EN/IEC 60947-5-5, Machinery directive 2006/42/EC and Work equipment directive 2009/104/EC standards. These emergency stop rope pull switches can be equipped with trip indicators, cable tension adjustment can be performed using a turnbuckle. The emergency stop rope pull switch is intended for all machines requiring stopping of dangerous movement in the immediate vicinity of the machine. The emergency stop rope pull switch is designed to avert hazards (dangerous phenomena) at the earliest possible moment or to reduce risks which could cause injury to persons or damage either to machines or work in progress.

Specifications

CertificationsCCC
Net Weight0.91 kg
StandardEN/IEC 60204-1
Storage Temperature-40-70 °C
Warranty Length18 months

Specifications

Range Of ProductTelemecanique Emergency stop rope pull switches XY2C
Product Or Component Typelatching emergency stop rope pull switch
Housing Colourred RAL 3000
Overvoltage Categoryclass I EN/IEC 61140 || class I NF C 20-030
Device Short NameXY2CH

Contractual warranty

Warranty18 months

Complementary

Resetby key-release push-button
Net Weight0.91 kg
[Uimp] Rated Impulse Withstand Voltage6 kV EN/IEC 60947-1
Trigger Cable Maximum Length30 m
Connections - Terminalsscrew clamp terminal, 1 x 0.5...2 x 1.5 mm²
Contacts Type And Composition1 NC + 1 NO
[Ui] Rated Insulation Voltage500 V 3)EN/IEC 60947-1 || 300 VUL 508
[Ie] Rated Operational Current3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Contact Operationslow-break
Distance Between Cable Supports5-5 m
Mechanical Durability800000 cycles
Number Of Cables1
Cable Entry Number3 tapped entry Pg 13.5 cable gland
Compatibility CodeXY2CH
Body Materialzamak
Trigger Cable Anchor PointRH or LH side
Safety Reliability DataB10d = 4000000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Cover Materialstainless steel
Tightening Torque0.8-1.2 N.m
Maximum Resistance Across Terminals25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Safety Levelcan reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Terminals Description Iso N°1(13-14)NO || (21-22)NC
Key Number421
Short-Circuit Protection10 A cartridge fuse gG EN/IEC 60269
Positive Openingwith EN/IEC 60947-5-1
[Ithe] Conventional Enclosed Thermal Current10 A
MarkingCE
Local Signallingwithout pilot light

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP111159EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Ambient Air Temperature For Operation-25-70 °C
Standardsmachinery directive 2006/42/EC || EN/IEC 60204-1 || work equipment directive 2009/104/EC || EN/IEC 60947-5-1 || EN/ISO 13850 || EN/IEC 60947-5-5
Product CertificationsUL category NISD emergency stop devices || CCC
Shock Resistance50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance10 gn 10-150 Hz)EN/IEC 60068-2-6
Ip Degree Of ProtectionIP65 IEC 60529