Telemecanique emergency stop rope pull switches XY2C, rope pull switch XY2CH, 240 V, AC, 10 A, XY2C
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 213.30
- Nuova Elva code
- XY2CH14270TK
- Manufacturer code
- XY2CH14270TK
- Availability
- Send request for quotation
Specifications
Certifications | CCC Category NISD Emergency Stop Devices |
---|---|
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Specifications | |
Range Of Product | Telemecanique Emergency stop rope pull switches XY2C |
Overvoltage Category | class I EN/IEC 61140 || class I NF C 20-030 |
Device Short Name | XY2CH |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
[Ui] Rated Insulation Voltage | 400 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14 |
[Ie] Rated Operational Current | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A |
Mechanical Durability | 800000 cycles |
Compatibility Code | XY2CH |
[Ithe] Conventional Enclosed Thermal Current | 10 A |
Safety Reliability Data | B10d = 4000000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5 |
Marking | CE |
Tightening Torque | 0.8-1.2 N.m |
Safety Level | can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Environment | |
Ambient Air Temperature For Operation | -40-70 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Product Certifications | CCC category NISD emergency stop devices || CE |
Shock Resistance | 50 gn 11 ms EN/IEC 60068-2-27 |
Vibration Resistance | 10 gn 10-300 Hz)EN/IEC 60068-2-6 |
Protective Treatment | TC |
Ip Degree Of Protection | IP66 IEC 60529 |