Latching emergency stop rope pull switch, Telemecanique Emergency stop rope pull switches XY2C, e XY2CH, 2NC+1 NO, booted pushbutton

Manufactured by:
Schneider Electric
Schneider electric

Eb25252aa69ca5a598f49d2ec6df88764c5cc8b5 medium
Price (VAT excluded)
€ 213.30
Nuova Elva code
XY2CH14290TK
Manufacturer code
XY2CH14290TK
Availability
Send request for quotation

Specifications

CertificationsCCC
Net Weight0.91 kg
StandardEN/IEC 60204-1
Storage Temperature-40-70 °C
Warranty Length18 months

Specifications

Housing Colourblue
Range Of ProductTelemecanique Emergency stop rope pull switches XY2C
Overvoltage Categoryclass I EN/IEC 61140 || class I NF C 20-030
Product Or Component Typelatching emergency stop rope pull switch
Device Short NameXY2CH

Contractual warranty

Warranty18 months

Complementary

Trigger Cable Maximum Length30 m
Contact Operationslow-break
Distance Between Cable Supports5-5 m
Mechanical Durability800000 cycles
Positive Openingwith EN/IEC 60947-5-1
Cable Entry Number3 tapped entry Pg 13.5 cable gland
Compatibility CodeXY2CH
Body Materialzamak
[Ithe] Conventional Enclosed Thermal Current6 A
Trigger Cable Anchor PointRH or LH side
Safety Reliability DataB10d = 4000000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Connections - Terminalsscrew clamp terminal, 1 x 0.34...1 x 1 mm² || screw clamp terminal, 1 x 0.34...2 x 0.75 mm²
MarkingCE
Cover Materialstainless steel
Local Signallingwithout pilot light
Net Weight0.91 kg
Tightening Torque0.8-1.2 N.m
[Uimp] Rated Impulse Withstand Voltage4 kV EN/IEC 60947-1
Maximum Resistance Across Terminals25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Safety Levelcan reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Resetby booted push-button
Contacts Type And Composition2 NC + 1 NO
Number Of Cables1
Terminals Description Iso N°1(21-22)NC || (31-32)NC || (13-14)NO
[Ui] Rated Insulation Voltage400 V 3)EN/IEC 60947-1 || 300 VUL 508
Short-Circuit Protection6 A cartridge fuse gG EN/IEC 60269
[Ie] Rated Operational Current0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1 appendix A || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 appendix A

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Toxic Heavy Metal FreeYes
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Ambient Air Temperature For Operation-40-70 °C
Ambient Air Temperature For Storage-40-70 °C
Environmental Characteristiccorrosive
Standardswork equipment directive 2009/104/EC || EN/ISO 13850 || EN/IEC 60947-5-5 || EN/IEC 60204-1 || EN/IEC 60947-5-1 || machinery directive 2006/42/EC
Product CertificationsUL category NISD emergency stop devices || CCC
Shock Resistance50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance10 gn 10-150 Hz)EN/IEC 60068-2-6
Protective TreatmentTC
Ip Degree Of ProtectionIP65 IEC 60529

Docs


Other Schneider Electric items

Request a quote