Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CJ, straight, 2NC Pg13.5

Manufactured by:
Schneider Electric
Schneider electric

0c60fdc018857c88de4849b99fb4180d85a5d88b medium
Price (VAT excluded)
€ 51.39
Nuova Elva code
XY2CJS17
Manufacturer code
XY2CJS17
Availability
Send request for quotation

This XY2CJ Emergency Stop Rope pull Switch is designed with a right hand side or a left hand side anchor point, allowing operator to trigger the stop of potentially dangerous machines at any point of its working area. It operates with a maximum rope length of 20 meters. It has a Zamak body with a pull button reset, Treated steel cover, color indicator, and 2 normally closed slow break contacts. Its B10D reliability data is 500 000. This emergency stop rope pull switch is suitable for woodworking machines, shears, conveyor systems, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works, etc. Its IP66 / IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-5, EN/ISO 13850, UL NISD, CSA C22.2 No 14-13 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.

Specifications

CertificationsCCC
Net Weight0.455 kg
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C

Specifications

Range Of ProductTelemecanique Emergency stop rope pull switches XY2C
Product Or Component Typelatching emergency stop rope pull switch
Housing Colourred RAL 3000
Overvoltage Categoryclass I EN/IEC 61140
Device Short NameXY2C

Complementary

Resetby pull button
Net Weight0.455 kg
[Uimp] Rated Impulse Withstand Voltage6 kV EN/IEC 60947-1
Trigger Cable Maximum Length20 m
Connections - Terminalsscrew clamp terminal, 1 x 0.5...2 x 1.5 mm²
Contacts Type And Composition2 NC
[Ui] Rated Insulation Voltage500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
[Ie] Rated Operational Current3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Contact Operationslow-break
Distance Between Cable Supports5-5 m
Mechanical Durability100000 cycles
Number Of Cables1
Cable Entry Number1 tapped entry Pg 13.5 cable gland
Compatibility CodeXY2CJ
Body Materialzamak
Trigger Cable Anchor PointRH or LH side
Safety Reliability DataB10d = 500000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Cover Materialgalvanised steel
Tightening Torque0.8-1.2 N.m
Maximum Resistance Across Terminals25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Safety Levelcan reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Terminals Description Iso N°1(11-22)NC || (21-22)NC
Short-Circuit Protection10 A cartridge fuse gG EN/IEC 60269
Positive Openingwith EN/IEC 60947-5-1
[Ithe] Conventional Enclosed Thermal Current10 A
MarkingCE
Head MaterialPA (polyamide)
Local Signallingcolor indicator

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP1407003EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Ambient Air Temperature For Operation-25-70 °C
StandardsEN/IEC 60947-5-1 || CSA C22.2 No 14 || UL 508 || EN/IEC 60947-5-5 || EN/ISO 13850 || machinery directive 2006/42/EC || EN/IEC 60204-1 || work equipment directive 2009/104/EC
Product CertificationsUL category NISD emergency stop devices || CSA || CCC || EAC
Shock Resistance50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance10 gn 10-150 Hz)EN/IEC 60068-2-6
Ip Degree Of ProtectionIP66 IEC 60529 || IP67 IEC 60529
Ambient Air Temperature For Storage-40-70 °C
Protective TreatmentTC

Docs


Other Schneider Electric items

Request a quote