Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CJ, straight, 2NC+1 NO, ISO M20
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 55.94
- Nuova Elva code
- XY2CJS19H29
- Manufacturer code
- XY2CJS19H29
- Availability
- Send request for quotation
This product is part of the XY2C range, an offer of emergency stop rope pull switches. This emergency stop rope pull switch has 2 normally closed + 1 normally opened, slow-break contacts with positive opening operation. It is a switch with a rated operational current of 0.1A at 250V AC, 1.5A at 240V AC and a conventional enclosed thermal current of 6A. It is furnished with screw clamp terminals for electrical connection and 1 tapped entry for ISO M20 cable gland. The trigger cable anchor point at left hand side. It can reset by booted pull button. It offers long mechanical durability which is about 100000 operating cycles. It is an IP66 and IP67 rated product. The casing is made of Zamak (red) with stainless steel cover. Its dimensions are 40mm (Width) x 64.2mm (Depth) x 201mm (Height) and weighs 0.455kg. It is intended for all machine applications like woodworking machines, shears, conveyor systems, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works, etc. This product is certified by CCC, CSA and UL. It meets CSA C22.2 No 14, EN/ISO 13850, EN/IEC 60947-5-1, EN/IEC 60204-1, EN/IEC 60947-5-5, UL 508 Machinery directive 2006/42/EC and Work equipment directive 2009/104/EC standards. These emergency stop rope pull switches can be equipped with trip indicators, cable tension adjustment can be performed using a turnbuckle. The emergency stop rope pull switch is intended for all machines requiring stopping of dangerous movement in the immediate vicinity of the machine. The emergency stop rope pull switch is designed to avert hazards (dangerous phenomena) at the earliest possible moment or to reduce risks which could cause injury to persons or damage either to machines or work in progress.
Specifications
Certifications | CCC |
---|---|
Net Weight | 0.455 kg |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Specifications | |
Range Of Product | Telemecanique Emergency stop rope pull switches XY2C |
Product Or Component Type | latching emergency stop rope pull switch |
Housing Colour | red RAL 3000 |
Overvoltage Category | class I EN/IEC 61140 |
Device Short Name | XY2C |
Complementary | |
Reset | by pull button |
Net Weight | 0.455 kg |
[Uimp] Rated Impulse Withstand Voltage | 4 kV EN/IEC 60947-1 |
Trigger Cable Maximum Length | 20 m |
Connections - Terminals | screw clamp terminal, 1 x 0.34...1 x 1 mm² || screw clamp terminal, 1 x 0.34...2 x 0.75 mm² |
Contacts Type And Composition | 2 NC + 1 NO |
[Ui] Rated Insulation Voltage | 400 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14 |
[Ie] Rated Operational Current | 0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1 appendix A || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 appendix A |
Contact Operation | slow-break |
Distance Between Cable Supports | 5-5 m |
Mechanical Durability | 100000 cycles |
Number Of Cables | 1 |
Cable Entry Number | 1 tapped entry ISO M20 cable gland |
Compatibility Code | XY2CJ |
Body Material | zamak |
Trigger Cable Anchor Point | RH or LH side |
Safety Reliability Data | B10d = 500000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5 |
Cover Material | galvanised steel |
Tightening Torque | 0.8-1.2 N.m |
Maximum Resistance Across Terminals | 25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A |
Safety Level | can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Terminals Description Iso N°1 | (31-32)NC || (13-14)NO || (21-22)NC |
Short-Circuit Protection | 6 A cartridge fuse gG EN/IEC 60269 |
Positive Opening | with EN/IEC 60947-5-1 |
[Ithe] Conventional Enclosed Thermal Current | 6 A |
Marking | CE |
Head Material | PA (polyamide) |
Local Signalling | color indicator |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1407003EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Ambient Air Temperature For Operation | -25-70 °C |
Standards | work equipment directive 2009/104/EC || UL 508 || EN/ISO 13850 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || EN/IEC 60204-1 || EN/IEC 60947-5-5 || machinery directive 2006/42/EC |
Product Certifications | UL category NISD emergency stop devices || CSA || CCC || EAC |
Shock Resistance | 50 gn 11 ms EN/IEC 60068-2-27 |
Vibration Resistance | 10 gn 10-150 Hz)EN/IEC 60068-2-6 |
Ip Degree Of Protection | IP66 IEC 60529 || IP67 IEC 60529 |
Ambient Air Temperature For Storage | -40-70 °C |
Protective Treatment | TC |