Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CJ, straight, 2NC+1 NO, 1/2" NPT

Manufactured by:
Schneider Electric
Schneider%20electric

385c93fa6460835d06eca3fe4455604d67e15987 medium
Price (VAT excluded)
€ 57.54
Nuova Elva code
XY2CJS19H7
Manufacturer code
XY2CJS19H7
Availability
Send request for quotation

This product is part of the XY2C range, an offer of emergency stop rope pull switches. It is ideal for all machines requiring stopping of dangerous movement in the immediate vicinity of the machine. It is suitable for applications such as woodworking machines, shears, conveyor systems, printing machines, textile machines etc. This emergency stop rope pull switch has 2 normally closed and 1 normally opened, slow-break contacts with positive opening operation. It is a switch with a rated operational current of 0.1A at 250V AC, 1.5A at 240V AC and a conventional enclosed thermal current of 6A. It is furnished with screw clamp terminals for electrical connection. Switch has one 1/2 inch NPT tapped conduit entries. The trigger cable anchor point at right and left hand side. Switch is has a pull reset pushbutton. It offers long mechanical durability which is about 100000 operating cycles. It is an IP66 and IP67 rated product. The casing is made of Zamak (red) with galvanized steel cover. Its dimensions are 1.57 inches (Width) x 2.53 inches (Depth) x 7.55 inches (Height). This product meets UL508, CSA C22.2 No 14, EN/ISO 13850, EN/IEC 60947-5-1, EN/IEC 60204-1, EN/IEC 60947-5-5, machinery directive 2006/42/EC and work equipment directive 2009/104/EC standards. This product is certified by UL, CSA, EAC and CCC. XY2 range emergency stop rope pull switch is intended for all machines requiring stopping of a dangerous movement in the immediate vicinity of the machine.

Specifications

CertificationsCCC
Net Weight0.455 kg
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C

Specifications

Housing Colourred RAL 3000
Range Of ProductTelemecanique Emergency stop rope pull switches XY2C
Overvoltage Categoryclass I EN/IEC 61140
Product Or Component Typelatching emergency stop rope pull switch
Device Short NameXY2C

Complementary

Trigger Cable Maximum Length20 m
Contact Operationslow-break
Distance Between Cable Supports5-5 m
Mechanical Durability100000 cycles
Positive Openingwith EN/IEC 60947-5-1
Cable Entry Number1 tapped entry 1/2" NPT conduit entry
Compatibility CodeXY2CJ
Body Materialzamak
[Ithe] Conventional Enclosed Thermal Current6 A
Trigger Cable Anchor PointRH or LH side
Safety Reliability DataB10d = 500000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Connections - Terminalsscrew clamp terminal, 1 x 0.34...1 x 1 mm² || screw clamp terminal, 1 x 0.34...2 x 0.75 mm²
MarkingCE
Head MaterialPA (polyamide)
Cover Materialgalvanised steel
Local Signallingcolor indicator
Net Weight0.455 kg
Tightening Torque0.8-1.2 N.m
[Uimp] Rated Impulse Withstand Voltage4 kV EN/IEC 60947-1
Maximum Resistance Across Terminals25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Safety Levelcan reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Resetby pull button
Contacts Type And Composition2 NC + 1 NO
Number Of Cables1
Terminals Description Iso N°1(13-14)NO || (31-32)NC || (21-22)NC
[Ui] Rated Insulation Voltage400 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
Short-Circuit Protection6 A cartridge fuse gG EN/IEC 60269
[Ie] Rated Operational Current0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1 appendix A || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 appendix A

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP1407003EN
Sustainable Offer StatusGreen Premium product
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-70 °C
StandardsEN/IEC 60947-5-5 || CSA C22.2 No 14 || work equipment directive 2009/104/EC || EN/IEC 60947-5-1 || machinery directive 2006/42/EC || UL 508 || EN/ISO 13850 || EN/IEC 60204-1
Product CertificationsUL category NISD emergency stop devices || CSA || CCC || EAC
Shock Resistance50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance10 gn 10-150 Hz)EN/IEC 60068-2-6
Protective TreatmentTC
Ip Degree Of ProtectionIP66 IEC 60529 || IP67 IEC 60529

Docs


Other Schneider Electric items