MS116-1.6 Manual Motor Starter

Produttore:
ABB
Abb

374a5048430967c6908d1567dc12199330402308 medium
Prezzo (IVA esclusa)
€ 69.01
Codice Nuova Elva
1SAM250000R1006
Codice produttore
1SAM250000R1006
Disponibilità
Tempo di consegna standard: 5 giorni

The MS116-1.6 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 1.6 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.

Specifications

Ordering

Minimum Order Quantity1 piece
Customs Tariff Number85362010

Dimensions

Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length85.6 mm
Product Net Weight0.265 kg

Technical

Rated Operational Power AC-3 (Pe)(400 V) Three Phase 0.55 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 0.55 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (Ie)1.6 A
Rated Operational Current AC-3 (Ie)1.6 A
Rated Operational Current AC-3e (Ie)1.6 A
Rated Frequency (f)Main Circuit 50 HzMain Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Power Lossat Rated Operating Conditions per Pole 0.6 W
Number of Poles3
Conventional Free-air Thermal Current (Ith)Main Circuit 1.6 A
Degree of ProtectionHousing IP20Main Circuit Terminals IP10
Pollution Degree3
Electrical Durability100000 cycle
Mechanical Durability100000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²Flexible 1/2x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 4 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Recommended Screw DriverPozidriv 2
Mounting PositionPosition 1 to 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm
Actuator TypeRotary Handle
Contact Position IndicationON / OFF
StandardsIEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-1UL 60947-4-1
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 50 kA(400 V AC) 50 kA(440 V AC) 50 kA(500 V AC) 30 kA(690 V AC) 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 100 kA(400 V AC) 100 kA(440 V AC) 100 kA(500 V AC) 100 kA(690 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)20 A
Setting Range1.0 ... 1.6 A

Technical UL/CSA

Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Ampere Rating UL/CSA1.6 A
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 0.75 Hp(550 ... 600 V AC) Three Phase 0.75 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 1.6 A(208 V AC) Three Phase 1.6 A(220 ... 240 V AC) Three Phase 1.6 A(440 ... 480 V AC) Three Phase 1.6 A(550 ... 600 V AC) Three Phase 1.6 A
Locked Rotor Amps(200 V AC) Three Phase 9.6 A(208 V AC) Three Phase 9.6 A(220 ... 240 V AC) Three Phase 9.6 A(440 ... 480 V AC) Three Phase 9.6 A(550 ... 600 V AC) Three Phase 9.6 A
General Use Rating UL/CSA(600 V AC) 1.6 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-12 AWGStranded 1/2x 16-12 AWG
Tightening Torque UL/CSAMain Circuit 10 in·lb

Environmental

Ambient Air TemperatureAround the Enclosure 0 ... +40 °COperation -25 ... +70 °COperation Compensated -25 ... +55 °CStorage -50 ... +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-65g / 3 ... 150 Hz
RoHS StatusFollowing EU Directive 2011/65/EU

Container Information

Package Level 1 Unitsbox 1 piece
Package Level 1 Width92 mm
Package Level 1 Depth / Length95 mm
Package Level 1 Height50 mm
Package Level 1 Gross Weight0.28 kg
Package Level 1 EAN4013614320293
Package Level 2 Unitscarton 40 piece
Package Level 2 Width280 mm
Package Level 2 Depth / Length395 mm
Package Level 2 Height210 mm
Package Level 2 Gross Weight11.586 kg
Package Level 2 EAN4013614408663

Classifications

Object Classification CodeF
ETIM 4EC000074 - Motor protective circuit-breaker
ETIM 5EC000074 - Motor protective circuit-breaker
eClassV11.0 : 27370401
IDEA Granular Category Code (IGCC)4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
E-Number (Finland)3706006
E-Number (Sweden)3111940

Altri articoli da ABB