MS116-12 Manual Motor Starter
- Produttore:
- ABB
- Prezzo (IVA esclusa)
- € 73.32
- Codice Nuova Elva
- 1SAM250000R1012
- Codice produttore
- 1SAM250000R1012
- Disponibilità
- Tempo di consegna standard: 5 giorni
The MS116-12 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 12.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 25 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
Specifications
Ordering | |
---|---|
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85362010 |
Dimensions | |
Product Net Width | 45 mm |
Product Net Height | 90 mm |
Product Net Depth / Length | 85.6 mm |
Product Net Weight | 0.265 kg |
Technical | |
Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 5.5 kW |
Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 5.5 kW |
Rated Operational Voltage | Main Circuit 690 V AC |
Rated Operational Current (Ie) | 12 A |
Rated Operational Current AC-3 (Ie) | 12 A |
Rated Operational Current AC-3e (Ie) | 12 A |
Rated Frequency (f) | Main Circuit 50 HzMain Circuit 60 Hz |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
Rated Insulation Voltage (Ui) | 690 V |
Power Loss | at Rated Operating Conditions per Pole 1 W |
Number of Poles | 3 |
Conventional Free-air Thermal Current (Ith) | Main Circuit 12 A |
Degree of Protection | Housing IP20Main Circuit Terminals IP10 |
Pollution Degree | 3 |
Electrical Durability | 100000 cycle |
Mechanical Durability | 100000 cycle |
Terminal Type | Screw Terminals |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²Flexible 1/2x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 4 mm² |
Tightening Torque | Main Circuit 0.8 ... 1.2 N·m |
Wire Stripping Length | Main Circuit 9 mm |
Recommended Screw Driver | Pozidriv 2 |
Mounting Position | Position 1 to 6 |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm |
Actuator Type | Rotary Handle |
Contact Position Indication | ON / OFF |
Standards | IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-1UL 60947-4-1 |
Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 25 kA(400 V AC) 25 kA(440 V AC) 6 kA(500 V AC) 6 kA(690 V AC) 2 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 50 kA(400 V AC) 50 kA(440 V AC) 15 kA(500 V AC) 10 kA(690 V AC) 3 kA |
Rated Instantaneous Short-Circuit Current Setting (Ii) | 180 A |
Setting Range | 8.0 ... 12 A |
Technical UL/CSA | |
Short-Circuit Current Rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
Ampere Rating UL/CSA | 12 A |
Horsepower Rating UL/CSA | (200 V AC) Three Phase 3 Hp(208 V AC) Three Phase 3 Hp(220 ... 240 V AC) Three Phase 3 Hp(440 ... 480 V AC) Three Phase 7.5 Hp(550 ... 600 V AC) Three Phase 10 Hp |
Full Load Amps Motor Use | (200 V AC) Three Phase 11 A(208 V AC) Three Phase 10.6 A(220 ... 240 V AC) Three Phase 9.6 A(440 ... 480 V AC) Three Phase 11 A(550 ... 600 V AC) Three Phase 11 A |
Locked Rotor Amps | (200 V AC) Three Phase 73.6 A(208 V AC) Three Phase 71 A(220 ... 240 V AC) Three Phase 64 A(440 ... 480 V AC) Three Phase 63.5 A(550 ... 600 V AC) Three Phase 64.8 A |
General Use Rating UL/CSA | (600 V AC) 12 A |
Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-8 AWGStranded 1/2x 16-8 AWG |
Tightening Torque UL/CSA | Main Circuit 10 in·lb |
Environmental | |
Ambient Air Temperature | Around the Enclosure 0 ... +40 °COperation -25 ... +70 °COperation Compensated -25 ... +55 °CStorage -50 ... +80 °C |
Ambient Air Temperature Compensation | Yes |
Maximum Operating Altitude Permissible | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
Resistance to Vibrations acc. to IEC 60068-2-6 | 5g / 3 ... 150 Hz |
RoHS Status | Following EU Directive 2011/65/EU |
Container Information | |
Package Level 1 Units | box 1 piece |
Package Level 1 Width | 92 mm |
Package Level 1 Depth / Length | 95 mm |
Package Level 1 Height | 50 mm |
Package Level 1 Gross Weight | 0.28 kg |
Package Level 1 EAN | 4013614348211 |
Package Level 2 Units | carton 40 piece |
Package Level 2 Width | 280 mm |
Package Level 2 Depth / Length | 395 mm |
Package Level 2 Height | 210 mm |
Package Level 2 Gross Weight | 11.586 kg |
Package Level 2 EAN | 4013614408724 |
Classifications | |
Object Classification Code | F |
ETIM 4 | EC000074 - Motor protective circuit-breaker |
ETIM 5 | EC000074 - Motor protective circuit-breaker |
eClass | V11.0 : 27370401 |
IDEA Granular Category Code (IGCC) | 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers |
E-Number (Finland) | 3705821 |
E-Number (Sweden) | 3111949 |