A 3-pole Contactor suitable for DC-1 applications where all three poles must be connected in series in a 1-pole configuration up to max 1000 VDC. Operated with wide control voltage range 100-250 V, AC/DC

Specifications

Ordering

Minimum Order Quantity1 piece
Customs Tariff Number85364900

Dimensions

Product Net Width438 mm
Product Net Depth / Length244 mm
Product Net Height392 mm
Product Net Weight33 kg

Technical

Rated Operational VoltageMain Circuit 1000 V
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 2050 A
Rated Operational Current DC-1 (Ie)(1000 V) 3 Poles in Series, 40 °C 2050 A(1000 V) 3 Poles in Series, 55 °C 1750 A(1000 V) 3 Poles in Series, 70 °C 1500 A(220 V) 3 Poles in Series, 40 °C 2050 A(220 V) 3 Poles in Series, 55 °C 1750 A(220 V) 3 Poles in Series, 70 °C 1500 A(400 V) 3 Poles in Series, 40 °C 2050 A(400 V) 3 Poles in Series, 55 °C 1750 A(400 V) 3 Poles in Series, 70 °C 1500 A(600 V) 3 Poles in Series, 40 °C 2050 A(600 V) 3 Poles in Series, 55 °C 1750 A(600 V) 3 Poles in Series, 70 °C 1500 A
Rated Insulation Voltage (Ui)acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Mechanical Durability0.5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 48 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 48 V·AHolding at Max. Rated Control Circuit Voltage DC 16 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 1900 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 1900 V·APull-in at Max. Rated Control Circuit Voltage DC 1700 W
Connecting Capacity Main CircuitBar 100 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeMain Circuit: Bars
Number of Main Contacts NO1
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(1000 V DC) 2050 A(440 V DC) 2050 A(600 V DC) 2050 A

Environmental

Ambient Air TemperatureOperation -40 ... +80 °CStorage -40 ... +70 °C
Maximum Operating Altitude Permissible3000 m
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Container Information

Package Level 1 Unitsbox 1 piece
Package Level 1 Width555 mm
Package Level 1 Depth / Length365 mm
Package Level 1 Height500 mm
Package Level 1 Gross Weight35 kg
Package Level 1 EAN7320500408254

Classifications

Object Classification CodeQ
ETIM 4EC002552 - Power contactor, DC switching
ETIM 5EC002552 - Power contactor, DC switching
eClassV11.0 : 27371018
IDEA Granular Category Code (IGCC)4763 >> Power contactor, DC switching