GAF460-10-11 250-500V 50/60Hz / 250-500V DC Contactor
- Produttore:
- ABB
A 3-pole Contactor suitable for DC-1 applications where all three poles must be connected in series in a 1-pole configuration up to max 1000 VDC. Operated with wide control voltage range 250-500 V, AC/DC
Specifications
Classifications | |
---|---|
Object Classification Code | Q |
ETIM 4 | EC002552 - Power contactor, DC switching |
ETIM 5 | EC002552 - Power contactor, DC switching |
ETIM 6 | EC002552 - Power contactor, DC switching |
ETIM 7 | EC002552 - Power contactor, DC switching |
UNSPSC | 39121529 |
IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Container Information | |
Package Level 1 Height | 310 mm |
Package Level 1 Gross Weight | 12 kg |
Package Level 1 EAN | 7320500383988 |
Package Level 1 Units | box 1 piece |
Package Level 1 Width | 280 mm |
Package Level 1 Depth / Length | 375 mm |
Technical UL/CSA | |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
General Use Rating UL/CSA | (1000 V DC) 650 A(440 V DC) 650 A(600 V DC) 650 A |
Environmental | |
Ambient Air Temperature | Operation -40 ... +70 °CStorage -40 ... +70 °C |
Maximum Operating Altitude Permissible | 3000 m |
Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 K40Shock Direction: B1 5 K40Shock Direction: B2 5 K40Shock Direction: C1 5 K40Shock Direction: C2 5 K40 |
RoHS Status | Following EU Directive 2011/65/EU |
Technical | |
Number of Main Contacts NO | 1 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 1 |
Number of Auxiliary Contacts NC | 1 |
Rated Operational Voltage | Main Circuit 1000 V |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 700 A |
Rated Operational Current DC-1 (Ie) | (1000 V) 3 Poles in Series, 40 °C 700 A(1000 V) 3 Poles in Series, 55 °C 600 A(1000 V) 3 Poles in Series, 70 °C 480 A(220 V) 3 Poles in Series, 40 °C 700 A(220 V) 3 Poles in Series, 55 °C 600 A(220 V) 3 Poles in Series, 70 °C 480 A(400 V) 3 Poles in Series, 40 °C 700 A(400 V) 3 Poles in Series, 55 °C 600 A(400 V) 3 Poles in Series, 70 °C 480 A(600 V) 3 Poles in Series, 40 °C 700 A(600 V) 3 Poles in Series, 55 °C 600 A(600 V) 3 Poles in Series, 70 °C 480 A |
Rated Insulation Voltage (Ui) | acc. to UL/CSA 1000 V |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
Mechanical Durability | 5 million |
Maximum Mechanical Switching Frequency | 300 cycles per hour |
Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
Rated Control Circuit Voltage (Uc) | 50 Hz 250 ... 500 V60 Hz 250 ... 500 VDC Operation 250 ... 500 V |
Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 4 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 890 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 890 V·APull-in at Max. Rated Control Circuit Voltage DC 990 W |
Connecting Capacity Main Circuit | Bar 47 mmRigid Al-Cable 240 m²Rigid Cu-Cable 240 m² |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5Flexible with Insulated Ferrule 2x 0.75 ... 2.5Flexible 2x0.75 ... 2.5 m²Solid 1 x 1 ... 4 m²Stranded 2 x 1 .... 4 m² |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
Terminal Type | Main Circuit: Bars |
Dimensions | |
Product Net Width | 186 mm |
Product Net Depth / Length | 216 mm |
Product Net Height | 278 mm |
Product Net Weight | 10.6 kg |
Ordering | |
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85364900 |