MS165-54 Manual Motor Starter

Produttore:
ABB
Abb

2fb631e15aef1a6d3106bf9c2b9b313fb8a8c096 medium
Codice Nuova Elva
MS16554
Codice produttore
1SAM451000R1016
Disponibilità
Tempo di consegna standard: 11 giorni

MS165 is a compact and powerful range for motor protection up to 45 kW (400 V) / 80 A in width of 55 mm. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.

Specifications

Ordering

Minimum Order Quantity1 piece
Customs Tariff Number85362010

Dimensions

Product Net Width55 mm
Product Net Height142.65 mm
Product Net Depth / Length122.1 mm
Product Net Weight0.97 kg

Technical

Rated Operational Power AC-3 (Pe)(400 V) Three Phase 22 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 22 kW
Rated Operational VoltageMain Circuit 690 V ACMain Circuit 250 V DC
Rated Operational Current (Ie)54 A
Rated Operational Current AC-3 (Ie)54 A
Rated Operational Current AC-3e (Ie)54 A
Rated Operational Current DC-5 (Ie)54 A
Rated Frequency (f)Main Circuit 50 HzMain Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Rated Insulation Voltage (Ui)1000 V
Power Lossat Rated Operating Conditions per Pole 3.84 W
Number of Poles3
Conventional Free-air Thermal Current (Ith)Main Circuit 54 A
Degree of ProtectionHousing IP20Main Circuit Terminals IP10
Pollution Degree3
Electrical Durability25000 cycle
Mechanical Durability50000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1 ... 35 mm²Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²Flexible 1/2x 1 ... 35 mm²Rigid 1/2x 1 ... 4 mm²Solid 1/2x 1 ... 4 mm²Stranded 1/2x 1 ... 50 mm²
Tightening TorqueMain Circuit 4 N·m
Wire Stripping LengthMain Circuit 16 mm
Recommended Screw DriverPozidriv 2
Mounting PositionPosition 1 to 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 1000 V 1.5 mmElectrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm
Actuator TypeRotary Handle
Contact Position IndicationON / OFF / TRIP
StandardsCSA 22.2 No. 14IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-4-1
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 30 kA(250 V DC) 3 Poles in Series 100 kA(400 V AC) 30 kA(440 V AC) 30 kA(500 V AC) 20 kA(690 V AC) 6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 50 kA(250 V DC) 100 kA(400 V AC) 50 kA(440 V AC) 45 kA(500 V AC) 20 kA(690 V AC) 8 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)810 A
Setting Range40 ... 54 A

Technical UL/CSA

Short-Circuit Current Rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kAManual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Ampere Rating UL/CSA54 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 15 Hp(208 V AC) Three Phase 15 Hp(220 ... 240 V AC) Three Phase 20 Hp(440 ... 480 V AC) Three Phase 40 Hp(550 ... 600 V AC) Three Phase 50 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 48.3 A(208 V AC) Three Phase 46.2 A(220 ... 240 V AC) Three Phase 54 A(440 ... 480 V AC) Three Phase 52 A(550 ... 600 V AC) Three Phase 52 A
Locked Rotor Amps(200 V AC) Three Phase 267 A(208 V AC) Three Phase 257 A(220 ... 240 V AC) Three Phase 290 A(440 ... 480 V AC) Three Phase 290 A(550 ... 600 V AC) Three Phase 290 A
General Use Rating UL/CSA(600 V AC) 54 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-0 AWGStranded 1/2x 16-0 AWG
Tightening Torque UL/CSAMain Circuit 35 in·lb

Environmental

Ambient Air TemperatureOperation -25 ... +60 °COperation Compensated -25 ... +60 °CStorage -50 ... +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-65g / 3 ... 150 Hz
RoHS StatusFollowing EU Directive 2011/65/EU

Container Information

Package Level 1 Unitsbox 1 piece
Package Level 1 Width78 mm
Package Level 1 Depth / Length155 mm
Package Level 1 Height155 mm
Package Level 1 Gross Weight1.1 kg
Package Level 1 EAN4013614486104
Package Level 2 Unitscarton 12 piece
Package Level 2 Width330 mm
Package Level 2 Depth / Length400 mm
Package Level 2 Height320 mm
Package Level 2 Gross Weight13 kg
Package Level 2 EAN4013614503962

Classifications

Object Classification CodeF
ETIM 5EC000074 - Motor protective circuit-breaker
eClassV11.0 : 27370401
IDEA Granular Category Code (IGCC)4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
E-Number (Finland)3707289
E-Number (Sweden)3110056

Documentazione