MULTIVERT 400A, 3-pole switching, mod. V-terminal, integrated C.T. triple pole

Produttore:
Mersen/Ferraz Shawmut
Mersen ferraz shawmut

15ba470034bbb3a349f865f4848673f4914d41cf medium
Prezzo (IVA esclusa)
€ 517.27
Codice Nuova Elva
S1023217
Codice produttore
S1023217
Disponibilità
Invia RdO

MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 400A are for installation on to 185mm bus bar systems. MULTIVERT® 400A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 2 400A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.

Features

  • Installation on to 185 mm bus bar system

  • Direct installation without drilling with hooked clamps possible

  • Symmetrical switch - top/bottom cable terminal connection

  • Touch protection IP 30 with central cover

  • Integrated measuring transformer (optional) with unchanged installation depth

  • Safe on load connection/disconnection in accordance with IEC 60947-3

  • IEC/EN 60 947-3

  • For NH-fuse links size 2 in accordance with IEC/EN 60 269-2, VDE 0636-2

Specifications

Country of OriginChina
Frequency50 Hz
Number of Poles3

Specifications

Standard design with M 12 screwsM = 35 ±3Nm
Power Dissipation Without Solid Links151 W
Rated Impulse Withstand Voltage12 kV
Rated Insulation Voltage1000 V
Rated Sc Withstand8 kA / 1 s
Rated Voltage Ac Iec690 V
Rated Short Circuit Making Capacity With Solid Links Icm16 kA
Country Of OriginCN,CZ
Product LineMULTIVERT® 400A , Size 2, 690VAC
Product BrandMULTIVERT®
Fuse Size2
Varieties of cable terminationbolt, insert nut, V-terminal
Installation MountingBus bar system 185 mm
Number Of Poles3-Pole
Utilization CategoryAC 23 B @ Ue = AC 400 V; Ie = 400 A
Utilization Category 2AC 22 B @ Ue = AC 500 V; Ie = 400 A
Utilization Category 3AC 21 B @ Ue = AC 690 V; Ie = 400 A
Switchability1 x triple pole, 3 x single pole
Frequency Hz50 ... 60 Hz Hz
Short Circuit Current Rating Sccr120kA@Ue = AC 400 V; Ie = 400 A / 120kA@Ue = AC 500 V; Ie = 400 A / 120kA@Ue = AC 690 V; Ie = 315 A / 100kA@Ue = AC 690 V; Ie = 400 A
Conventional Free Air Thermal Current - Solid Links630 A
Conventional Free Air Thermal Current With Fuse-Links Ith400 A
Max Power Dissipation Of Fuse Links Pn34 W
Max Power Dissipation Of Solid Links Pn9 W
Power Dissipation By Ith Without Fuse-Links61 W

Documentazione


Altri articoli da Mersen/Ferraz Shawmut

Richiedi un preventivo