Sensor/actuator cable - SAC-5P- 3,0-PUR/M12FR - 1669864
- Produttore:
- PHOENIX CONTACT
Sensor/actuator cable, 5-position, PUR halogen-free, black-gray RAL 7021, free cable end, on Socket angled M12, coding: A, cable length: 3 m
Features
Easy and safe: 100% electrically tested plug-in components
Our standard: robust halogen-free PUR cable
cULus Listed
UL Listed
cUL Listed
Specifications
Cable Length | 3 m |
---|---|
Cable | |
Cable type | PUR halogen-free black |
Cable type (abbreviation) | PUR |
UL AWM style | 20549 |
Conductor cross section | 5x 0.34 mm² (Signal line) |
AWG signal line | 22 |
Conductor structure signal line | 42x 0.10 mm |
Core diameter including insulation | 1.27 mm ±0.02 mm (Signal line) |
Thickness, insulation | approx. 0.5 mm |
Wire colors | brown, white, blue, black, green-yellow |
External sheath, color | black-gray RAL 7021 |
External cable diameter D | 4.55 mm ±0.15 mm |
Smallest bending radius, fixed installation | 23 mm |
Smallest bending radius, movable installation | 46 mm |
Number of bending cycles | 10000000 |
Bending radius | 50 mm |
Traversing path | 10 m |
Traversing rate | 3 m/s |
Acceleration | 10 m/s² |
Cable weight | 33 kg/km |
Outer sheath, material | PUR |
Material conductor insulation | PP |
Conductor material | Bare Cu litz wires |
Insulation resistance | ≥ 16 GΩ*km (at 20 °C) |
Conductor resistance | max. 58 Ω/km (at 20 °C) |
Nominal voltage, cable | 300 V |
Test voltage, cable | 3000 V |
Special properties | Flexible cable conduit capable |
Special properties | Silicone-free |
Special properties | Free of substances which would hinder coating with paint or varnish |
Special properties | flexible |
Flame resistance | in accordance with UL 758/1581 FT2 |
Flame resistance | DIN EN 60332-2-2 (20 s) |
Halogen-free | in accordance with DIN VDE 0472 part 815 |
Resistance to oil | in accordance with DIN EN 60811-2-1 |
Other resistance | Highly resistant to acids, alkaline solutions and solvents |
Other resistance | hydrolysis and microbe resistant |
Other resistance | Resistant to salt water |
Other resistance | partly UV-resistant in accordance with DIN EN ISO 4892-2-A |
Ambient temperature (operation) | -40 °C - 80 °C (cable, fixed installation) |
Ambient temperature (operation) | -25 °C - 80 °C (cable, flexible installation) |
Dimensions | |
Length of cable | 3 m |
Stripping length of the free conductor end | 50 mm |
Material | |
Flammability rating according to UL 94 | HB |
Contact material | CuSn |
Contact surface material | Ni/Au |
Contact carrier material | TPU GF |
Material of grip body | TPU, hardly inflammable, self-extinguishing |
Material, knurls | Zinc die-cast, nickel-plated |
Sealing material | NBR |
Ambient conditions | |
Ambient temperature (operation) | -25 °C - 90 °C (Plug / socket) |
Degree of protection | IP65 |
Degree of protection | IP67 |
Degree of protection | IP68 |
Standards and Regulations | |
Standards/specifications | M12 connector IEC 61076-2-101 |
Flammability rating according to UL 94 | HB |
Environmental Product Compliance | |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
China RoHS | No hazardous substances above threshold values |