I/O module - AXL F AO4 1H - 2688527

Produttore:
PHOENIX CONTACT
Phoenix contact

728632dab409f873d2b231d1d7de9f31da361622 medium
Prezzo (IVA esclusa)
€ 431.31
Codice Nuova Elva
2688527
Codice produttore
2688527
Disponibilità
Invia RdO

Axioline F, Analog output module, Analog outputs: 4, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors

Features

  • 4 analog output channels for the connection of either voltage or current signals

  • Bipolar voltage outputs, unipolar current outputs

  • Connection of actuators in 2-wire technology

  • Voltage ranges: 0 V ... 10 V, ±10 V, 0 V ... 5 V, ±5 V

  • Current ranges: 0 mA ... 20 mA, 4 mA ... 20 mA

  • Short-circuit-proof outputs

  • No derating in all ranges

  • Short signal rise times

  • Driving of high loads

  • Device rating plate stored

  • BV

  • BSH

  • cULus Listed

  • EAC

  • LR

  • RINA

  • PRS

  • NK

  • DNV GL

  • KR

  • ABS

  • UL Listed

  • cUL Listed

Specifications

Depth54 mm
Height126.1 mm
Strip Length8 mm
Width35 mm

Axioline potentials

DesignationAxioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Current consumptiontyp. 120 mA
Current consumptionmax. 150 mA
DesignationSupply for analog modules (UA)
Supply voltage24 V DC
Supply voltage range19.2 V DC - 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 60 mA (4 voltage channels, 10 V output)
Current consumptionmax. 85 mA (4 voltage channels, 10 V output)
Current consumptionmax. 110 mA (4 current channels, 20 mA output, 500 Ω load)
Current consumptionmax. 125 mA (4 current channels, 24 mA output, 500 Ω load)
Power consumptionmax. 3 W (at UA)
Power consumptiontyp. 2.04 W (at UBus and UA)
Power consumptionmax. 3.75 W (at UBus and UA)
Protective circuitSurge protection of the supply voltage electronic (35 V, 0.5 s)
Protective circuitPolarity reversal protection of the supply voltage Polarity protection diode
Protective circuitTransient protection Suppressor diode

Electrical isolation

Test section5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
Test section5 V supply (logic)/analog outputs 500 V AC 50 Hz 1 min.
Test section5 V supply of the local bus (UBus) / functional ground 500 V AC 50 Hz 1 min.
Test section24 V supply (I/O)/analog outputs 500 V AC 50 Hz 1 min.
Test section24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Test sectionAnalog outputs/functional earth ground 500 V AC 50 Hz 1 min.

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50 years
China RoHSFor details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the 'Axioline F: system and installation' user manual.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Dimensions

Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).

Interfaces

DesignationAxioline F local bus
No. of channels2
Connection methodBus base module
Transmission speed100 Mbps

Analog outputs

Number of outputs4
Connection methodPush-in connection
Connection technology2-wire
Note regarding the connection technologyshielded, twisted pair
Output nameAnalog outputs
D/A converter resolution16 bit
Type of protectionShort-circuit and overload protection
Type of protectionTransient protection
Protective circuit/componentelectronic
Protective circuit/componentSuppressor diode
Data formatsIB IL, S7-compatible
Representation of output values16 bits (15 bits + sign)
Process data update140 µs
Current output signal0 mA - 20 mA
Current output signal4 mA - 20 mA
Load/output load current output≤ 500 Ω
Voltage output signal0 V - 5 V
Voltage output signal-5 V - 5 V
Voltage output signal0 V - 10 V
Voltage output signal-10 V - 10 V
Load/output load voltage output≥ 1 kΩ
Precisiontyp. 0.1 % (of output range final value)

Ambient conditions

Air pressure (operation)70 kPa - 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa - 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20
Ambient temperature (operation)-25 °C - 60 °C
Ambient temperature (storage/transport)-40 °C - 85 °C
Permissible humidity (operation)5 % - 95 % (non-condensing)
Permissible humidity (storage/transport)5 % - 95 % (non-condensing)

Standards and Regulations

Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Mechanical testsShock in acc. with EN 60068-2-27/IEC 60068-2-27 30g
Mechanical testsContinuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection classIII (IEC 61140, EN 61140, VDE 0140-1)