Safety relays - PSR-MC20-3NO-1DO-24DC-SC - 2700466

Produttore:
PHOENIX CONTACT
Phoenix contact

2a421079d710ddd6c9b10bf575b5b137effeed30 medium
Prezzo (IVA esclusa)
€ 127.30
Codice Nuova Elva
2700466
Codice produttore
2700466
Disponibilità
Invia RdO

Safety relay for emergency stop and safety doors up to SILCL 1, Cat. 1, PL c, depending on the application up to SILCL 3, Cat. 4, PL e, 1-channel operation, automatic/manual start, 3 enabling current paths, US = 24 V DC, plug-in screw terminal block

Features

  • Up to Cat. 1/PL c according to ISO 13849-1, SILCL 1 according to IEC 62061

  • Depending on the application, up to Cat. 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061

  • Low housing width of just 12.5 mm

  • Single-channel control

  • 3 enabling current paths, 1 digital signal output

  • Manually monitored and automatic activation in a single device

  • cULus Listed

  • EAC

  • Functional Safety

  • UL Listed

  • cUL Listed

Specifications

Depth114.5 mm
Height112.2 mm
Strip Length7 mm
Voltage2 V
Width12.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C - 55 °C (observe derating)
Ambient temperature (storage/transport)-40 °C - 85 °C
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Maximum altitude≤ 2000 m (Above sea level)

Safety-related characteristic data

DesignationEN 62061
Safety Integrity Level Claim Limit (SIL CL)1 (up to SILCL 3 depending on the application)
Stop category0
DesignationIEC 61508 - High demand
DesignationIEC 61508 - Low demand
Safety Integrity Level (SIL)1 (up to SIL 3 depending on the application)
DesignationEN ISO 13849
Performance level (PL)c (up to PL e depending on the application)
Category1 (up to Cat. 4 depending on the application)

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50 years
China RoHSFor details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Dimensions

Width12.5 mm
Height112.2 mm
Depth114.5 mm

Times

Typical pickup time at US< 250 ms (when controlled via A1)
Typical response time at US< 175 ms (automatic start)
Typical response time at US< 175 ms (manual, monitored start)
Typical release time at US< 20 ms (when controlled via A1 or S12)
Recovery time< 500 ms

Connection data

Connection methodScrew connection
pluggableYes
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM3
Torque0.5 Nm - 0.6 Nm

Power supply

DesignationA1/A2
Rated control circuit supply voltage US24 V DC -15 % / +10 %
Rated control circuit supply voltage US20.4 V DC - 26.4 V DC
Rated control supply current IStyp. 80 mA
Power consumption at UStyp. 1.92 W
Inrush current5 A (Δt = 200 µs at Us)
Filter time1 ms (at A1 in the event of voltage dips at Us)
Protective circuitSurge protection Suppressor diode
Protective circuitProtection against polarity reversal for rated control circuit supply voltage

Digital inputs

Input nameSensor circuit
Input nameS11, S12
Description of the inputsafety-related sensor inputs
Input voltage range "0" signal0 V DC - 5 V DC (for safe Off; at S12)
Input current range "0" signal0 mA - 2 mA (for safe Off; at S12)
Inrush current< 21 mA (with Us/Ix to S12)
Current consumption< 5 mA (with Us/Ix to S12)
Filter timemax. 1.5 ms (at S12; test pulse width)
Filter timemin. 7.5 ms (at S12; test pulse rate)
Filter timeTest pulse rate = 5 x Test pulse width
Max. permissible overall conductor resistance150 Ω
Input nameStart circuit
Input nameS34
Description of the inputnon-safety-related
Number of inputs1
Input voltage range "1" signal20.4 V DC - 26.4 V DC
Inrush currenttyp. 200 mA
Current consumption< 10 mA ()
Current consumption> -5 mA ()
Protective circuit/componentSuppressor diode

Alarm outputs

DesignationM1
Output descriptionnon-safety-related
Number of outputs1 (digital, PNP)
Voltage22 V DC (Us - 2 V)
Currentmax. 100 mA
Maximum inrush current500 mA (Δt = 1 ms at Us)
Short-circuit protectionno

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Rated insulation voltage250 V AC
Rated surge voltage/insulationSafe isolation, reinforced insulation 6 kV between input circuit and enabling current path (13/14) and enabling current path (23/24) and enabling current path (33/34) Basic insulation 4 kV between all current paths and housing
Degree of pollution2
Overvoltage categoryIII
Shock15g
Vibration (operation)10 Hz - 150 Hz, 2g
ConformanceCE-compliant

Relay outputs- enabling current path

Output nameEnabling current paths
Output name13/14, 23/24, 33/34
Output descriptionsafety-related N/O contacts
Number of outputs3 (undelayed)
Contact type3 enabling current paths
Contact materialAgSnO₂
Switching voltagemin. 12 V AC/DC
Switching voltagemax. 250 V AC/DC (Observe the load curve)
Limiting continuous current6 A (observe derating)
Inrush currentmin. 3 mA
Inrush currentmax. 6 A
Sq. Total current48 A² (observe derating)
Switching capacitymin. 60 mW
Switching frequency0.5 Hz
Mechanical service life10x 10⁶ cycles
Output fuse6 A gL/gG (N/O contact)
Output fuse4 A gL/gG (for low-demand applications)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area