Safety relays - PSR-MC20-3NO-1DO-24DC-SC - 2700466
- Produttore:
- PHOENIX CONTACT
Safety relay for emergency stop and safety doors up to SILCL 1, Cat. 1, PL c, depending on the application up to SILCL 3, Cat. 4, PL e, 1-channel operation, automatic/manual start, 3 enabling current paths, US = 24 V DC, plug-in screw terminal block
Features
Up to Cat. 1/PL c according to ISO 13849-1, SILCL 1 according to IEC 62061
Depending on the application, up to Cat. 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061
Low housing width of just 12.5 mm
Single-channel control
3 enabling current paths, 1 digital signal output
Manually monitored and automatic activation in a single device
cULus Listed
EAC
Functional Safety
UL Listed
cUL Listed
Specifications
Depth | 114.5 mm |
---|---|
Height | 112.2 mm |
Strip Length | 7 mm |
Voltage | 2 V |
Width | 12.5 mm |
Ambient conditions | |
Ambient temperature (operation) | -40 °C - 55 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C - 85 °C |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Maximum altitude | ≤ 2000 m (Above sea level) |
Safety-related characteristic data | |
Designation | EN 62061 |
Safety Integrity Level Claim Limit (SIL CL) | 1 (up to SILCL 3 depending on the application) |
Stop category | 0 |
Designation | IEC 61508 - High demand |
Designation | IEC 61508 - Low demand |
Safety Integrity Level (SIL) | 1 (up to SIL 3 depending on the application) |
Designation | EN ISO 13849 |
Performance level (PL) | c (up to PL e depending on the application) |
Category | 1 (up to Cat. 4 depending on the application) |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Dimensions | |
Width | 12.5 mm |
Height | 112.2 mm |
Depth | 114.5 mm |
Times | |
Typical pickup time at US | < 250 ms (when controlled via A1) |
Typical response time at US | < 175 ms (automatic start) |
Typical response time at US | < 175 ms (manual, monitored start) |
Typical release time at US | < 20 ms (when controlled via A1 or S12) |
Recovery time | < 500 ms |
Connection data | |
Connection method | Screw connection |
pluggable | Yes |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Torque | 0.5 Nm - 0.6 Nm |
Power supply | |
Designation | A1/A2 |
Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
Rated control circuit supply voltage US | 20.4 V DC - 26.4 V DC |
Rated control supply current IS | typ. 80 mA |
Power consumption at US | typ. 1.92 W |
Inrush current | 5 A (Δt = 200 µs at Us) |
Filter time | 1 ms (at A1 in the event of voltage dips at Us) |
Protective circuit | Surge protection Suppressor diode |
Protective circuit | Protection against polarity reversal for rated control circuit supply voltage |
Digital inputs | |
Input name | Sensor circuit |
Input name | S11, S12 |
Description of the input | safety-related sensor inputs |
Input voltage range "0" signal | 0 V DC - 5 V DC (for safe Off; at S12) |
Input current range "0" signal | 0 mA - 2 mA (for safe Off; at S12) |
Inrush current | < 21 mA (with Us/Ix to S12) |
Current consumption | < 5 mA (with Us/Ix to S12) |
Filter time | max. 1.5 ms (at S12; test pulse width) |
Filter time | min. 7.5 ms (at S12; test pulse rate) |
Filter time | Test pulse rate = 5 x Test pulse width |
Max. permissible overall conductor resistance | 150 Ω |
Input name | Start circuit |
Input name | S34 |
Description of the input | non-safety-related |
Number of inputs | 1 |
Input voltage range "1" signal | 20.4 V DC - 26.4 V DC |
Inrush current | typ. 200 mA |
Current consumption | < 10 mA () |
Current consumption | > -5 mA () |
Protective circuit/component | Suppressor diode |
Alarm outputs | |
Designation | M1 |
Output description | non-safety-related |
Number of outputs | 1 (digital, PNP) |
Voltage | 22 V DC (Us - 2 V) |
Current | max. 100 mA |
Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
Short-circuit protection | no |
Standards and Regulations | |
Designation | Air clearances and creepage distances between the power circuits |
Standards/regulations | DIN EN 50178 |
Rated insulation voltage | 250 V AC |
Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV between input circuit and enabling current path (13/14) and enabling current path (23/24) and enabling current path (33/34) Basic insulation 4 kV between all current paths and housing |
Degree of pollution | 2 |
Overvoltage category | III |
Shock | 15g |
Vibration (operation) | 10 Hz - 150 Hz, 2g |
Conformance | CE-compliant |
Relay outputs- enabling current path | |
Output name | Enabling current paths |
Output name | 13/14, 23/24, 33/34 |
Output description | safety-related N/O contacts |
Number of outputs | 3 (undelayed) |
Contact type | 3 enabling current paths |
Contact material | AgSnO₂ |
Switching voltage | min. 12 V AC/DC |
Switching voltage | max. 250 V AC/DC (Observe the load curve) |
Limiting continuous current | 6 A (observe derating) |
Inrush current | min. 3 mA |
Inrush current | max. 6 A |
Sq. Total current | 48 A² (observe derating) |
Switching capacity | min. 60 mW |
Switching frequency | 0.5 Hz |
Mechanical service life | 10x 10⁶ cycles |
Output fuse | 6 A gL/gG (N/O contact) |
Output fuse | 4 A gL/gG (for low-demand applications) |
Note | |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |