Distributed I/O device - FLM DIO 8/4 M8 - 2773351
- Produttore:
- PHOENIX CONTACT
The space-saving local bus device is particularly suitable for use in close proximity to the process. Functions: 4 digital inputs, 4 digital I/Os of 500 mA, maximum, channel-specific diagnostics, short-circuit/overload protection, M8 connection method.
Features
Can also be connected to an Inline station
Optimized for 30 mm mounting profile
Diagnostic and status indicators
Short-circuit and overload protection
Consistent connection via M8 connectors
cULus Recognized
UL Recognized
cUL Recognized
Specifications
Depth | 26.5 mm |
---|---|
Height | 143 mm |
Width | 29.8 mm |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Dimensions | |
Caption | Side view (dimensions in mm) |
Width | 29.8 mm |
Height | 143 mm |
Depth | 26.5 mm |
Note on dimensions | Length details incl. fixing clips |
Drill hole spacing | 133 mm |
Digital inputs | |
Input name | Digital inputs |
Description of the input | IEC 61131-2 type 1 |
Connection method | M8 connector |
Connection technology | 2, 3-wire |
Number of inputs | 8 (4 fixed, 4 freely selectable) |
Protective circuit | Reverse polarity protection |
Nominal input voltage UIN | 24 V DC |
Filter time | 3 ms |
Input voltage | 24 V DC |
Input voltage range "0" signal | -30 V DC - 5 V DC |
Input voltage range "1" signal | 13 V DC - 30 V DC |
Interfaces | |
Designation | Fieldline local bus |
Connection method | M8 connector |
Designation connection point | Copper cable |
Transmission speed | 500 kbps |
Number of positions | 4 |
Digital outputs | |
Output name | Digital outputs |
Connection method | M8 connector |
Connection technology | 2, 3-wire |
Number of outputs | 4 (Can also be used as an input) |
Protective circuit | Short-circuit protection |
Output voltage | 24 V DC |
Maximum output current per channel | 500 mA |
Electrical isolation | |
Test section | To I/O 500 V AC |
Ambient conditions | |
Ambient temperature (storage/transport) | -25 °C - 85 °C |
Permissible humidity (operation) | 5 % - 95 % |
Permissible humidity (storage/transport) | 10 % - 95 % |
Air pressure (operation) | 80 kPa - 106 kPa (up to 2000 m above sea level) |
Air pressure (storage/transport) | 70 kPa - 106 kPa (up to 3000 m above sea level) |
Degree of protection | IP65/IP67 |
Ambient temperature (operation) | -25 °C - 60 °C |
Power supply for module electronics | |
Connection method | M8 connector |
Designation | UL |
Number of positions | 4 |
Supply voltage | 24 V DC |
Supply voltage range | 18 V DC - 30 V DC (including ripple) |
Supply current | 3 A |
Fieldline potentials | |
Voltage supply UL | 24 V DC |
Standards and Regulations | |
Connection in acc. with standard | CUL |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Note | |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |