Power supply unit 2866297
- Produttore:
- PHOENIX CONTACT
Primary-switched MINI POWER power supply for DIN rail mounting, input: 1-phase, output: 10 V DC ... 15 V DC/8 A
Features
Easy-maintenance connection technology thanks to keyed COMBICON connectors
Remote monitoring of output voltage via switching output
cULus Listed
cULus Listed
EAC
cULus Recognized
EAC
UL Listed
cUL Listed
UL Listed
cUL Listed
UL Recognized
cUL Recognized
Specifications
Height | 99 mm |
---|---|
Operating Temperature | -25 °C |
Protection Rating | IP20 |
Width | 67.5 mm |
Output data | |
Nominal output voltage | 12 V DC ±1 % |
Nominal output voltage | 10 V DC ±1 % |
Nominal output voltage | 15 V DC ±1 % |
Setting range of the output voltage (U<sub>Set</sub>) | 10 V DC - 15 V DC (> 12 V DC, constant capacity restricted) |
Nominal output current (I<sub>N</sub>) | 8 A (-25 °C - 60 °C) |
POWER BOOST (I<sub>Boost</sub>) | 6.6 A (-25°C - 40°C permanent ) |
Derating | 60 °C - 70 °C (2.5%/K) |
Connection in parallel | Yes, for assembling redundant systems and increasing efficiency |
Connection in series | yes |
Residual ripple | < 40 mVPP (20 MHz) |
Output power | 100 W |
Typical response time | < 0.4 s |
Peak switching voltages nominal load | < 100 mVPP (20 MHz) |
Maximum power dissipation in no-load condition | < 2.5 W |
Power loss nominal load max. | < 12 W |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 25; |
China RoHS | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Standards and Regulations | |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 55011 (EN 55022) |
Noise immunity | EN 61000-6-2:2005 |
Connection in acc. with standard | CUL |
Low Voltage Directive | Conformance with LV directive 2006/95/EC |
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage | EN 60950-1 (SELV) |
Standard – Safety extra-low voltage | EN 60204 (PELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
UL approvals | UL/C-UL listed UL 508 |
UL approvals | UL/C-UL Recognized UL 60950-1 |
UL approvals | UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
Rail applications | EN 50121-4 |
Dimensions | |
Width | 67.5 mm |
Height | 99 mm |
Depth | 107 mm |
Connection data, input | |
Connection method | Pluggable screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Connection data, output | |
Connection method | Pluggable screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Input data | |
Input voltage range | 90 V DC - 350 V DC |
AC frequency range | 45 Hz - 65 Hz |
Current consumption | 1.3 A (120 V AC) |
Current consumption | 0.8 A (230 V AC) |
Current consumption | 1.3 A (90 V DC) |
Current consumption | 0.4 A (350 V DC) |
Nominal power consumption | 109.1 W |
Inrush surge current | < 15 A (typical) |
Mains buffering | > 20 ms (120 V AC) |
Mains buffering | > 20 ms (230 V AC) |
Input fuse | 3.15 A (slow-blow, internal) |
Choice of suitable circuit breakers | 6 A - 16 A |
Nominal input voltage range | 100 V AC - 240 V AC |
Input voltage range | 85 V AC - 264 V AC |
Ambient conditions | |
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C - 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (storage/transport) | -40 °C - 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Connection data for signaling | |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Screw thread | M3 |