Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566

Produttore:
PHOENIX CONTACT
Phoenix%20contact

7f699e996a88daf7a2de06b7fdba8ce2b2c492bc medium
Prezzo (IVA esclusa)
€ 184.69
Codice Nuova Elva
2900566
Codice produttore
2900566
Disponibilità
Invia RdO

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL3 /PL e, and screw connection.

Features

  • 22.5 mm wide

  • Safety level according to IEC 61508-1: SIL 3, ISO 13849: PL e

  • Reduction in wiring

  • Long service life

  • Space saving

  • 3-phase loop bridges

  • Adjustable current for bimetal function

  • Low-wear switching

  • GL

  • GL-SW

  • CCC

  • EAC

  • IECEE CB Scheme

  • ATEX

  • UL Listed

  • cUL Listed

Specifications

Depth114 mm
Height107 mm
Strip Length8 mm
Width22.5 mm

Insulation characteristics

Rated insulation voltage500 V
Rated surge voltage6 kV
Overvoltage categoryIII
Degree of pollution2
DesignationInsulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit
InsulationSafe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC
InsulationBasic isolation (IEC 60947-1) at operating voltage 300 - 500 V AC
InsulationSafe isolation (EN 50178) at operating voltage 300 - 500 V AC
DesignationIsolation characteristics between the control input and control supply voltage to auxiliary circuit
InsulationSafe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
InsulationSafe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50 years
China RoHSFor details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Dimensions

Width22.5 mm
Height107 mm
Depth114 mm

UL data

SCCR100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
SCCR5 kA (500 V AC (fuse: 20 A RK5 (standard fault)))
FLA0.6 A (500 V AC)
Group installation20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
Group installation30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Category codeNLDX

Connection data

Connection nameControl circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² - 2.5 mm²
Conductor cross section flexible0.2 mm² - 2.5 mm²
Conductor cross section AWG24 - 14
Torque0.5 Nm - 0.6 Nm
Torque5 lbf-in. - 7 lbf-in.

Connection data 2

Connection nameLoad circuit
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² - 2.5 mm²
Conductor cross section flexible0.2 mm² - 2.5 mm²
Conductor cross section AWG24 - 14
Torque0.5 Nm - 0.6 Nm
Torque5 lbf-in. - 7 lbf-in.

Input data

Input nameControl input
Rated actuating voltage UC24 V DC
Triggering voltage range19.2 V DC - 30 V DC
Rated actuating current IC5 mA (Input type 1)
Switching threshold9.6 V ('0' signal)
Switching threshold19.2 V ('1' signal)
Switching level< 5 V DC (For EMERGENCY STOP)
Typical turn-off time< 30 ms
Type of protectionReverse polarity protection

Conformance/approvals

DesignationATEX
IdentificationII (2) G [Ex e] [Ex d] [Ex px]
IdentificationII (2) D [Ex t] [Ex p]
CertificatePTB 07 ATEX 3145
DesignationUL approval
CertificateNLDX.E228652
DesignationSafety Integrity Level (SIL, IEC 61508)
Identification≤ 3
Additional textSafe shutdown
Identification2
Additional textMotor protection
DesignationPerformance Level (ISO 13849)
Identification≤ e
DesignationCategory (ISO 13849)

Ambient conditions

Ambient temperature (operation)-25 °C - 70 °C (observe derating)
Ambient temperature (storage/transport)-40 °C - 80 °C
Maximum altitude≤ 2000 m
Degree of protectionIP20

Output data reply output

Output nameAcknowledge output
NoteConfirmation: floating change-over contact, signal contact
Contact type1 PDT
Switching capacity according to IEC 60947-5-13 A (230 V, AC15)
Switching capacity according to IEC 60947-5-12 A (24 V, DC13)

Output data load output

Output nameAC output
Rated operating voltage Ue500 V AC
Operating voltage range42 V AC - 550 V AC
Rated operating current Ie0.6 A (AC-51)
Rated operating current Ie0.6 A (AC-53a)
Mains frequency50/60 Hz
Load current range75 mA - 600 mA (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2Class 10A
Cooling time20 min. (for auto reset)
Leakage current0 mA
Type of protectionSurge protection

Device supply

Rated control supply current IS40 mA
Type of protectionSurge protection
Type of protectionReverse polarity protection
Rated control circuit supply voltage US24 V DC
Control supply voltage range19.2 V DC - 30 V DC

Standards and Regulations

DesignationStandards/regulations
Standards/regulationsIEC 60947-1
Standards/regulationsIEC 60947-4-2
Standards/regulationsIEC 61508
Standards/regulationsISO 13849

Spesso acquistati assieme


Altri articoli da PHOENIX CONTACT

Richiedi un preventivo