Safety relays - PSR-SPP-120UC/ESAM4/3X1/1X2/B - 2901425
- Produttore:
- PHOENIX CONTACT
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, 1- or 2-channel operation, 3 enabling current paths, nominal input voltage: 120 V AC/DC, pluggable Push-in terminal block
Features
Up to Cat.4/PL e according to EN ISO 13849-1, SILCL 3 according to EN 62061, SIL 3 according to IEC 61508
Manually monitored and automatic activation in a single device
3 enabling current paths, 1 signaling current path
Single and two-channel control
Basic insulation
Time saving push-in connection, tools not required
Potentials can be easily looped through – ideal for BUS applications
Intuitive use through colour coded actuation lever
Can be combined with the MSTB 2,5 range
Quick and convenient testing using integrated test option
cULus Listed
EAC
Functional Safety
UL Listed
cUL Listed
Specifications
Depth | 114.5 mm |
---|---|
Height | 112 mm |
Strip Length | 8 mm |
Width | 22.5 mm |
Ambient conditions | |
Ambient temperature (operation) | -25 °C - 55 °C |
Ambient temperature (storage/transport) | -40 °C - 85 °C |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Maximum altitude | ≤ 2000 m (Above sea level) |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Standards and Regulations | |
Designation | Air clearances and creepage distances between the power circuits |
Standards/regulations | DIN EN 50178/VDE 0160 |
Rated insulation voltage | 250 V AC |
Rated surge voltage/insulation | 4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV between A1-A2/logic/enabling and signaling current paths) |
Degree of pollution | 2 |
Overvoltage category | III |
Shock | 15g |
Vibration (operation) | 10 Hz - 150 Hz, 2g |
Dimensions | |
Width | 22.5 mm |
Height | 112 mm |
Depth | 114.5 mm |
Input data | |
Input voltage range | 110 V AC/DC - 120 V AC/DC |
Input voltage range in reference to UN | 0.85 - 1.1 |
Typical input current at UN | 38 mA |
Voltage at input/start and feedback circuit | ~ 24 V DC |
Typical response time | 40 ms (man. start) |
Typ. starting time with Us | 330 ms (when controlled via A1) |
Typical release time | 60 ms (when controlled via A1) |
Typical release time | 20 ms (when controlled via S11/S12 and S21/S22) |
Concurrence input 1/2 | ∞ |
Recovery time | 1 s |
Operating voltage display | Green LED |
Status display | Green LED |
Protective circuit | Surge protection Varistor 275 VRMS (A1-A2) |
Protective circuit | Surge protection Varistor |
Maximum switching frequency | 0.5 Hz |
Max. permissible overall conductor resistance | 50 Ω |
Connection data | |
Connection method | Push-in connection |
pluggable | Yes |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Output data | |
Contact type | 3 enabling current paths |
Contact type | 1 signaling current path |
Contact material | AgSnO₂, + 0.2 µm Au |
Maximum switching voltage | 250 V AC/DC |
Minimum switching voltage | 10 V AC/DC |
Limiting continuous current | 6 A (N/O contact) |
Limiting continuous current | 5 A (N/C contact) |
Maximum inrush current | 6 A |
Inrush current, minimum | 10 mA |
Sq. Total current | 72 A² |
Interrupting rating (ohmic load) max. | 144 W (24 V DC, τ = 0 ms) |
Interrupting rating (ohmic load) max. | 230 W (48 V DC, τ = 0 ms) |
Interrupting rating (ohmic load) max. | 68 W (110 V DC, τ = 0 ms) |
Interrupting rating (ohmic load) max. | 88 W (220 V DC, τ = 0 ms) |
Interrupting rating (ohmic load) max. | 2000 VA (250 V AC, τ = 0 ms) |
Maximum interrupting rating (inductive load) | 48 W (24 V DC, τ = 40 ms) |
Maximum interrupting rating (inductive load) | 40 W (48 V DC, τ = 40 ms) |
Maximum interrupting rating (inductive load) | 35 W (110 V DC, τ = 40 ms) |
Maximum interrupting rating (inductive load) | 33 W (220 V DC, τ = 40 ms) |
Switching capacity min. | 100 mW |
Mechanical service life | approx. 10⁷ cycles |
Switching capacity (360/h cycles) | 6 A (24 V DC) |
Switching capacity (360/h cycles) | 5 A (230 V AC) |
Output fuse | 10 A gL/gG NEOZED (N/O contact) |
Output fuse | 6 A gL/gG NEOZED (N/C contact) |
Safety-related characteristic data | |
Stop category | 0 |
Designation | IEC 61508 - High demand |
Safety Integrity Level (SIL) | 3 |
Designation | IEC 61508 - Low demand |
Designation | EN ISO 13849 |
Performance level (PL) | e |
Category | 4 |
Designation | EN 62061 |
Safety Integrity Level Claim Limit (SIL CL) | 3 |
Designation | EN 50156 |
Note | |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |