Frequency transducer - MINI MCR-SL-F-UI-NC - 2902832
- Produttore:
- PHOENIX CONTACT
The configurable frequency transducer is suitable for the connection of NAMUR proximity sensors as well as for sensors with NPN and PNP outputs. Configurable via DIP switch and teach-in wheel. Screw connection, standard configuration.
Features
cULus Listed
ATEX
EAC Ex
GL
UL Listed
cUL Listed
Specifications
Depth | 101.2 mm |
---|---|
Height | 93.1 mm |
Strip Length | 12 mm |
Width | 6.2 mm |
Ambient conditions | |
Ambient temperature (operation) | -20 °C - 65 °C |
Ambient temperature (storage/transport) | -40 °C - 85 °C |
Permissible humidity (operation) | 5 % - 95 % (non-condensing) |
Degree of protection | IP20 |
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Power supply | |
Supply voltage range | 9.6 V DC - 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) |
Typical current consumption | < 28 mA (at IOUT = 20 mA, 24 V DC, load 500 Ω) |
Power consumption | < 800 mW (at IOUT = 20 mA, 9.6 V DC, load 500 Ω) |
Dimensions | |
Width | 6.2 mm |
Height | 93.1 mm |
Depth | 101.2 mm |
Output data | |
Output name | Voltage output / current output |
Number of outputs | 1 |
Configurable/programmable | Yes |
Voltage output signal | 0 V - 5 V |
Voltage output signal | 1 V - 5 V |
Voltage output signal | 0 V - 10 V |
Voltage output signal | 10 V - 0 V |
Current output signal | 0 mA - 20 mA |
Current output signal | 4 mA - 20 mA |
Current output signal | 20 mA - 0 mA |
Current output signal | 20 mA - 4 mA |
Max. output voltage | approx. 12.3 V |
Max. output current | 24.6 mA |
Load/output load voltage output | ≥ 10 kΩ |
Load/output load current output | 500 Ω (at 20 mA) |
Ripple | < 20 mVPP |
Ripple | < 20 mVPP (at 500 Ω) |
Step response (0–99%) | < 35 ms (At f > 500 Hz) |
Connection data | |
Connection method | Screw connection |
Stripping length | 12 mm |
Screw thread | M3 |
Conductor cross section solid | 0.2 mm² - 2.5 mm² |
Conductor cross section flexible | 0.2 mm² - 2.5 mm² |
Conductor cross section AWG | 26 - 12 |
Input data | |
Frequency input | Frequency input |
Configurable/programmable | Yes |
Frequency measuring range | 0.002 Hz - 20 kHz (DIP switch) |
Available input sources | NPN/PNP transistor outputs |
Available input sources | NAMUR initiators |
Available input sources | Floating relay contact (dry contact) |
Max. input amplitude | 30 V (incl. DC voltage) |
EMC data | |
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
Typical deviation from the measuring range final value | 0.1 % |
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Typical deviation from the measuring range final value | 2 % |
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Typical deviation from the measuring range final value | 0.3 % |
Standards and Regulations | |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Standards/regulations | EN 61000-4-2 |
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
Standards/regulations | EN 61000-4-4 |
Standards/regulations | EN 61000-4-5 |
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Electrical isolation | Basic insulation according to EN 61010 |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc X |
UL, USA/Canada | UL 508 Listed |
UL, USA/Canada | Class I, Div. 2, Groups A, B, C, D T4 |
UL, USA/Canada | Class I, Zone 2, Group IIC |
Note | |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |