Power supply unit - TRIO-PS-2G/1AC/24DC/20 - 2903151
- Produttore:
- PHOENIX CONTACT
Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single-phase, output: 24 V DC/20 A
Features
Save time and costs, thanks to the Push-in connection and narrow design
Increase system availability, thanks to dynamic boost with 150% of the nominal current for five seconds
Maximum flexibility due to the wide temperature range from -25°C to +70°C and device startup at -40°C
Rugged design
cULus Listed
cULus Recognized
EAC
DNV GL
IECEE CB Scheme
UL Listed
cUL Listed
UL Recognized
cUL Recognized
Specifications
Depth | 160 mm |
---|---|
Height | 130 mm |
Output Voltage | 24 V |
Strip Length | 10 mm |
Voltage | 10 V |
Width | 68 mm |
Output data | |
Nominal output voltage | 24 V DC ±1 % |
Setting range of the output voltage (USet) | 24 V DC - 28 V DC (> 24 V DC, constant capacity restricted) |
Nominal output current (IN) | 20 A |
Dynamic Boost (IDyn.Boost) | 30 A (5 s) |
Derating | > 60 °C - 70 °C (2.5%/K) |
Connection in parallel | Yes, for redundancy and increased capacity |
Connection in series | yes |
Feedback voltage resistance | ≤ 35 V DC |
Protection against overvoltage at the output (OVP) | ≤ 30 V DC |
Control deviation | < 1 % (change in load, static 10 % - 90 %) |
Control deviation | < 3 % (Dynamic load change 10 % - 90 %, 10 Hz) |
Control deviation | < 0.1 % (change in input voltage ±10 %) |
Residual ripple | < 100 mVPP (with nominal values) |
Output power | 480 W |
Typical response time | < 1 s |
Maximum power dissipation in no-load condition | < 2.9 W (120 V AC) |
Maximum power dissipation in no-load condition | < 2.8 W (230 V AC) |
Power loss nominal load max. | < 44.8 W (120 V AC) |
Power loss nominal load max. | < 36.8 W (230 V AC) |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 25; |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Standards | |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Rail applications | EN 50121-4 |
EMC requirements for noise immunity | EN 61000-6-1 |
EMC requirements for noise immunity | EN 61000-6-2 |
EMC requirements for noise emission | EN 61000-6-3 |
EMC requirements for noise emission | EN 61000-6-4 |
Standard - Safety of transformers | EN 61558-2-16 (air clearances and creepage distances only) |
Standard - Electrical safety | IEC 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage | IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Dimensions | |
Width | 68 mm |
Height | 130 mm |
Depth | 160 mm |
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 50 mm / 50 mm |
EMC data | |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Conducted noise emission | EN 55016 |
Conducted noise emission | EN 61000-6-3 (Class B) |
Noise emission | EN 55016 |
Noise emission | EN 61000-6-3 (Class B) |
Electrostatic discharge | EN 61000-4-2 |
Contact discharge | 6 kV (Test Level 4) |
Discharge in air | 8 kV (Test Level 4) |
Electromagnetic HF field | EN 61000-4-3 |
Frequency range | 80 MHz - 1 GHz |
Test field strength | 10 V/m (Test Level 3) |
Frequency range | 1 GHz - 2 GHz |
Frequency range | 2 GHz - 3 GHz |
Comments | Criterion A |
Fast transients (burst) | EN 61000-4-4 |
Input | 4 kV (Test Level 4 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 1 kV (Test Level 2 - asymmetrical) |
Surge voltage load (surge) | EN 61000-4-5 |
Input | 3 kV (Test Level 3 - symmetrical) |
Input | 6 kV (Test Level 4 - asymmetrical) |
Output | 1 kV (Test Level 2 - symmetrical) |
Output | 2 kV (Test Level 1 - asymmetrical) |
Comments | Criterion B |
Conducted interference | EN 61000-4-6 |
Frequency range | 0.15 MHz - 80 MHz |
Voltage | 10 V (Test Level 3) |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Input data | |
Nominal input voltage range | 100 V AC - 240 V AC |
Nominal input voltage range | 110 V DC - 250 V DC |
Input voltage range | 100 V AC - 240 V AC -15 % - +10 % |
Input voltage range | 110 V DC - 250 V DC ±10 % |
Dielectric strength maximum | ≤ 300 V AC 15 s |
AC frequency range | 50 Hz - 60 Hz ±10 % |
Discharge current to PE | < 3.5 mA |
Current consumption | 5.6 A (100 V AC) |
Current consumption | 4.3 A (120 V AC) |
Current consumption | 2.4 A (230 V AC) |
Current consumption | 2.4 A (240 V AC) |
Nominal power consumption | 534.7 VA |
Inrush current | ≤ 20 A (typical) |
Mains buffering time | typ. 10 ms (120 V AC) |
Mains buffering time | typ. 15 ms (230 V AC) |
Input fuse | 10 A (internal (device protection)) |
Recommended breaker for input protection | 10 A - 16 A (Characteristics B, C, D, K) |
Power factor (cos phi) | 0.98 |
Type of protection | Transient surge protection |
Protective circuit/component | Varistor |
Ambient conditions | |
Ambient temperature (storage/transport) | -40 °C - 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Installation height | ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m) |
Degree of protection | IP20 |
Inflammability class in acc. with UL 94 (housing / terminal blocks) | V0 |
Ambient temperature (operation) | -25 °C - 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (start-up type tested) | -40 °C |
Connection data, input | |
Connection method | Push-in connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 4 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 10 mm |
Connection data, output | |
Connection method | Push-in connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 10 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 6 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 8 |
Stripping length | 15 mm |
Conformance/approvals | |
UL approvals | UL Listed UL 508 |
UL approvals | UL/C-UL Recognized UL 60950-1 |
Shipbuilding approval | DNV GL |
Connection data for signaling | |
Connection method | Push-in connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |