Safety relay for emergency stop and safety door up to SIL 1, SIL CL 1, Cat. 1, PL c, depending on the application up to SIL 3, SIL CL 3, Cat. 4, PL e, single-channel operation, 4 enabling current paths, US = 24 V AC/DC, plug-in screw terminal blocks

Features

  • Up to Cat. 1/PL c according to ISO 13849-1, SILCL 1 according to IEC 62061, SIL 1 according to IEC 61508

  • Depending on the application, up to Cat. 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508

  • Basic insulation

  • Single-channel control

  • cULus Listed

  • EAC

  • Functional Safety

  • UL Listed

  • cUL Listed

Specifications

Depth114.5 mm
Height99 mm
Strip Length7 mm
Width22.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C - 65 °C (observe derating)
Ambient temperature (storage/transport)-40 °C - 70 °C
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Maximum altitude≤ 2000 m (Above sea level)

Input data

Rated control circuit supply voltage US24 V AC/DC -15 % / +10 %
Rated control supply current IStyp. 140 mA AC
Rated control supply current IStyp. 65 mA DC
Power consumption at UStyp. 3.36 W (AC)
Power consumption at UStyp. 1.56 W (DC)
Inrush current2 A (Δt = 10 ms at Us)
Inrush current< 40 mA (with Us/Ix to S34)
Current consumption< 50 mA (with Us/Ix to S12)
Current consumption0 mA (with Us/Ix to S34)
Voltage at input/start and feedback circuit24 V DC -15 % / +10 %
Typical response time< 65 ms (automatic start)
Typical response time< 40 ms (manual start)
Typ. starting time with Us< 65 ms (when controlled via A1)
Typical release time< 45 ms (when controlled via S12)
Typical release time< 200 ms (when controlled via A1)
Recovery time< 1 s
Operating voltage display1 x green LED
Status display2 x green LEDs
Protective circuitSurge protection Suppressor diode
Protective circuitProtection against polarity reversal for rated control circuit supply voltage
Maximum switching frequency1 Hz
Max. permissible overall conductor resistanceapprox. 22 Ω (Input and start circuits at US)
Filter time2 ms (at A1 in the event of voltage dips at Us)
Filter timemax. 1.5 ms (at S12; test pulse width)
Filter time7.5 ms (at S12; test pulse rate)
Filter timeTest pulse rate = 5 x Test pulse width

Safety-related characteristic data

Stop category0
DesignationIEC 61508 - High demand
Safety Integrity Level (SIL)1 (up to SIL 3 depending on the application)
DesignationIEC 61508 - Low demand
DesignationEN ISO 13849
Performance level (PL)c (up to PL e depending on the application)
Category1 (up to Cat. 4 depending on the application)
DesignationEN 62061
Safety Integrity Level Claim Limit (SIL CL)1 (up to SILCL 3 depending on the application)

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50 years
China RoHSFor details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Connection data

Connection methodScrew connection
pluggableYes
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM3

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178/VDE 0160
Rated insulation voltage250 V AC
Rated surge voltage/insulationBasic insulation 4 kV: between all current paths and housing Safe isolation, reinforced insulation 6 kV: between A1/A2 and 13/14, 23/24, 33/34, 43/44 between S11/S12/S33/S34 and 13/14, 23/24, 33/34, 43/44 between 51/52 and 13/14, 23/24, 33/34, 43/44
Degree of pollution2
Overvoltage categoryIII
Shock15g
Vibration (operation)10 Hz - 150 Hz, 2g
ConformanceCE-compliant

Output data

Contact type4 enabling current paths
Contact type1 signaling current path
Contact materialAgSnO₂
Maximum switching voltage250 V AC/DC (Observe the load curve)
Minimum switching voltage5 V AC/DC
Limiting continuous current6 A (N/O contact, pay attention to the derating)
Limiting continuous current6 A (N/C contact)
Maximum inrush current20 A (Δt  100 ms)
Inrush current, minimum10 mA
Sq. Total current72 A² (observe derating)
Interrupting rating (ohmic load) max.144 W (24 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.288 W (48 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.110 W (110 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.88 W (220 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.1500 VA (250 V AC, τ = 0 ms)
Maximum interrupting rating (inductive load)42 W (24 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)42 W (48 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)42 W (110 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)42 W (220 V DC, τ = 40 ms)
Switching capacity min.50 mW
Mechanical service life10x 10⁶ cycles
Switching capacity (360/h cycles)4 A (24 V DC)
Switching capacity (360/h cycles)4 A (230 V AC)
Output fuse10 A gL/gG (N/O contact)
Output fuse6 A gL/gG (N/C contact)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area