Relay Module - PLC-RSC- 24DC/21 - 2966171
- Produttore:
- PHOENIX CONTACT
PLC relay, consisting of base terminal block PLC-BSC.../21 with screw connection and pluggable miniature relay with power contact, for assembly on DIN rail NS 35/7.5, 1 PDT, input voltage 24 V DC
Features
Slim design
Efficient connection to system cabling using V8 adapter
RT III sealed relay
Safe isolation according to DIN EN 50178 between coil and contact
Functional plug-in bridges
Integrated input circuit and interference suppression circuit
cULus Listed
RC FRT
cULus Recognized
EAC
PRS
DNV GL
UL Listed
cUL Listed
UL Recognized
cUL Recognized
Specifications
Depth | 94 mm |
---|---|
Height | 80 mm |
Strip Length | 8 mm |
Width | 6.2 mm |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Note | |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
Type of note | Notes on operation |
Note | Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500.... |
Dimensions | |
Width | 6.2 mm |
Height | 80 mm |
Depth | 94 mm |
Contact side | |
Contact type | 1 PDT |
Type of switch contact | Single contact |
Contact material | AgSnO |
Maximum switching voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
Minimum switching voltage | 5 V (at 100 mA) |
Min. switching current | 10 mA (at 12 V) |
Maximum inrush current | 10 A (4 s) |
Limiting continuous current | 6 A |
Interrupting rating (ohmic load) max. | 140 W (at 24 V DC) |
Interrupting rating (ohmic load) max. | 20 W (at 48 V DC) |
Interrupting rating (ohmic load) max. | 18 W (at 60 V DC) |
Interrupting rating (ohmic load) max. | 23 W (at 110 V DC) |
Interrupting rating (ohmic load) max. | 40 W (at 220 V DC) |
Interrupting rating (ohmic load) max. | 1500 VA (for 250 V AC) |
Switching capacity | 2 A (at 24 V, DC13) |
Switching capacity | 0.2 A (at 110 V, DC13) |
Switching capacity | 0.1 A (at 220 V, DC13) |
Switching capacity | 3 A (at 24 V, AC15) |
Switching capacity | 3 A (at 120 V, AC15) |
Switching capacity | 3 A (at 230 V, AC15) |
Connection data | |
Connection name | Coil side |
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section solid | 0.14 mm² - 2.5 mm² |
Conductor cross section flexible | 0.14 mm² - 2.5 mm² |
Conductor cross section flexible | 0.2 mm² - 2.5 mm² (Single ferrule) |
Conductor cross section flexible | 2x 0.5 mm² - 1.5 mm² (TWIN ferrule) |
Conductor cross section AWG | 26 - 14 |
Connection data 2 | |
Connection name | Contact side |
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section solid | 0.14 mm² - 2.5 mm² |
Conductor cross section flexible | 0.14 mm² - 2.5 mm² |
Conductor cross section flexible | 0.2 mm² - 2.5 mm² (Single ferrule) |
Conductor cross section flexible | 2x 0.5 mm² - 1.5 mm² (TWIN ferrule) |
Conductor cross section AWG | 26 - 14 |
Coil side | |
Nominal input voltage UN | 24 V DC |
Typical input current at UN | 9 mA |
Typical response time | 5 ms |
Typical release time | 8 ms |
Protective circuit | Reverse polarity protection Polarity protection diode |
Protective circuit | Free-wheeling diode Damping diode |
Operating voltage display | Yellow LED |
Power dissipation for nominal condition | 0.22 W |
Standards and Regulations | |
Connection in acc. with standard | CUL |
Designation | Standards/regulations |
Standards/regulations | IEC 60664 |
Standards/regulations | EN 50178 |
Pollution degree | 3 |
Overvoltage category | III |
Ambient conditions | |
Degree of protection | IP20 (Relay base) |
Degree of protection | ≥ IP54 (Installation location) |
Ambient temperature (operation) | -40 °C - 60 °C |
Ambient temperature (storage/transport) | -40 °C - 85 °C |
Degree of protection | RT III (Relay) |