AZ 17-11ZK
- Produttore:
- SCHMERSAL
Features
cable gland M16
30 mm x 60 mm x 30 mm
Thermoplastic enclosure
Double-insulated
Long life
Small body
Universal coding
High level of contact reliability with low voltages and currents
Insensitive to soiling
8 actuating planes
This type termination (IDC) method enables simple connetion of flexible conductors without the need for the use of conductor ferrules
Specifications
Ambient Temperature | -30 °C |
---|---|
Certifications | BG |
Enclosure Material | Glass-fibre Reinforced Thermoplastic |
Standard | EN ISO 13849-1 |
Weight | 85 g |
Approval - Standards | |
Certificates | BG | cULus | CCC | EAC |
General data | |
Coding level according to ISO 14119 | Low |
Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Material of the contacts, electrical | Silver |
Gross weight | 85 g |
General data - Features | |
Number of auxiliary contacts | 1 |
Number of safety contacts | 1 |
Safety appraisal | |
Standards | EN ISO 13849-1 |
Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs | |
B10d Normally-closed contact (NC) | 2,000,000 Operations |
B10d Normally open contact (NO) | 1,000,000 Operations |
Note (B10d Normally open contact (NO)) | at 10% I | and ohmic load |
Mechanical data | |
Mechanical life, minimum | 1,000,000 Operations |
Latching force | 5 N |
positive break travel | 11 mm |
Positive break force, minimum | 17 N |
Actuating speed, maximum | 2 m/s |
Mechanical data - Connection technique | |
Terminal Connector | IDC method of termination |
Cable section, minimum | 1 x 0.75 mm² |
Cable section, maximum | 1 x 1 mm² |
Mechanical data - Dimensions | |
Length of sensor | 30 mm |
Width of sensor | 30 mm |
Height of sensor | 60 mm |
Ambient conditions | |
Degree of protection | IP67 to EN 60529 |
Ambient temperature, minimum | -30 °C |
Ambient temperature, maximum | +80 °C |
Ambient conditions - Insulation value | |
Rated insulation voltage U | 250 V |
Rated impulse withstand voltage U | 4 kV |
Electrical data | |
Thermal test current | 10 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 4 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 4 A |
Switching element | NO contact, NC contact |
Switching principle | Creep circuit element |
Scope of delivery | |
Included in delivery | Actuators must be ordered separately. | Slot cover for dust-proof covering of the opening not in use |