SINAMICS G120C 15HP LO Filtered USS/MB
- Produttore:
- SIEMENS
- Prezzo (IVA esclusa)
- € 2375.10
- Codice Nuova Elva
- 6SL32101KE226AB1
- Codice produttore
- 6SL3210-1KE22-6AB1
- Disponibilità
- Invia RdO
SINAMICS g120c rated power 11,0KW with 150% overload for 3 sec 3AC380-480v +10/-20% 47-63HZ integrated filter class a i/o-interface 6di, 2do,1ai,1ao safe torque off integrated fieldbus uss/ modbus rtu protection IP20/ ul open type size fsc 295x140x203(hxwxd) external 24v
Specifications
Country of Origin | United Kingdom |
---|---|
Number of Inputs | 6 |
Number of Phases | 3 |
Specifications | |
Country of Origin | GB |
Number of HW-interfaces USB | 1 |
Type of converter | U converter |
Degree of protection (IP) | IP20 |
Number of HW-interfaces other | 6 |
Number of interfaces PROFINET | 0 |
Number of HW-interfaces RS-232 | 1 |
Number of HW-interfaces RS-422 | 0 |
Number of HW-interfaces RS-485 | 1 |
Supporting protocol for ASI | false |
Supporting protocol for CAN | false |
With PC connection | true |
Supporting protocol for KNX | false |
Supporting protocol for LON | false |
Number of HW-interfaces parallel | 0 |
4-quadrant operation possible | false |
Integrated breaking resistance | true |
Supporting protocol for MODBUS | true |
Number of HW-interfaces serial TTY | 1 |
Supporting protocol for BACnet | false |
Supporting protocol for SERCOS | false |
Supporting protocol for TCP/IP | false |
Number of phases input | 3 |
Supporting protocol for SUCONET | false |
Supporting protocol for INTERBUS | false |
Supporting protocol for PROFIBUS | false |
Supporting protocol for DeviceNet | false |
Supporting protocol for PROFIsafe | false |
Supporting protocol for EtherNet/IP | false |
Supporting protocol for PROFINET IO | false |
Supporting protocol for SafetyBUS p | false |
Supporting protocol for Data-Highway | false |
Supporting protocol for PROFINET CBA | false |
Number of phases output | 3 |
Application in industrial area permitted | true |
Number of HW-interfaces industrial Ethernet | 0 |
Supporting protocol for INTERBUS-Safety | false |
Supporting protocol for DeviceNet Safety | false |
Supporting protocol for other bus systems | true |
Supporting protocol for Foundation Fieldbus | false |
Supporting protocol for AS-Interface Safety at Work | false |
Application in domestic- and commercial area permitted | true |
Number of digital inputs | 6 |
Number of analogue inputs | 1 |
Number of digital outputs | 2 |
Number of analogue outputs | 1 |
With optical interface | false |