variable speed drive ATV12 - 0.75kW - 1hp - 200..240V - 1ph - with heat sink

Produttore:
Schneider Electric
Schneider electric

C4f104bb6151f0c4b1ec959773a3ef41db186463 medium
Prezzo (IVA esclusa)
€ 267.77
Codice Nuova Elva
ATV12H075M2
Codice produttore
ATV12H075M2
Disponibilità
Invia RdO

Altivar Machine ATV12 is an offer of variable speed drives for commercial equipment and simple machines. It works at a rated power up to 0.75kW / 1hp and a rated voltage from 200V to 240V AC. It is designed with heatsink for normal environments and fan-cooled enclosure. It has advanced PID and catch on the fly functions, basic cabling, and easy motor control setting. Based on the needs, it can be delivered without heatsink, with embedded EMC filter, or as standard version. The Altivar 12 drive integrates as standard the Modbus communication protocol. This Altivar Machine ATV12 is designed for simple applications, in industry, commercial machines and HVAC machines such as conveyors, pumps, extractors, access barriers and treadmills. It conforms to IEC, UL and other international standards. SoMove software compatibility enables saving and transfering of configurations to spare drive, reducing maintenance downtime. It features an optimized application of power and torque for ventilation and pumping applications, this allows up to 30% energy savings.

Specifications

CertificationsC-tick
Depth131.2 mm
Height143 mm
Mounting TypeCabinet Mount
Net Weight0.8 kg
StandardEN/IEC 61800-3
Storage Temperature-25-70 °C
Warranty Length18 months
Width72 mm

Specifications

Product Or Component Typevariable speed drive
Motor Power Kw0.75 kW
[Us] Rated Supply Voltage200...240 V - 15...10 %
Mounting Modecabinet mount
Emc Filterintegrated
Ip Degree Of ProtectionIP20
Communication Port ProtocolModbus
Nominal Output Current4.2 A
Product Specific Applicationsimple machine
Maximum Horse Power Rating1 hp
Supply Frequency50/60 Hz +/- 5 %
Range Of ProductAltivar 12

Contractual warranty

Warranty18 months

Complementary

Prospective Line Isc1 kA
With Safety Function Safe Direction (Sdi)false
Type Of Polarizationno impedance
Frequency Resolutionanalog input converter A/D, 10 bits || display unit 0.1 Hz
Switching Frequency2...16 kHz adjustable || 4...16 kHz with derating factor
Maximum Transient Current6.3 A 60 s heavy duty) || 6.9 A 2 s heavy duty)
Communication Serviceread holding registers (03) 29 words || write single register (06) 29 words || write multiple registers (16) 27 words || read/write multiple registers (23) 4/4 words || read device identification (43)
Analogue Input Number1
Motor Slip Compensationpreset in factory || adjustable
Discrete Output Number2
With Safety Function Safe Position (Sp)false
Network Frequency50-60 Hz
Method Of Accessserver Modbus serial
With Safety Function Safely Limited Position (Slp)false
With Safety Function Safe Operating Stop (Sos)false
Number Of Addresses1-247
Speed Range1-20
Discrete Input Number4
Linearity Error+/- 0.3 % of maximum value analogue input
With Sft Fct Safe Stop 2 (Ss2)false
With Safety Function Safe Stop 1 (Ss1)false
Width72 mm
Power Dissipation In Wnatural 44.0 W
Transmission Rate9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
Depth131.2 mm
Sampling Duration20 ms +/- 1 ms logic input || 10 ms analogue input
Maximum Output Frequency4 kHz
With Safety Function Safe Brake Management (Sbc/Sbt)false
Height143 mm
Acceleration And Deceleration Rampslinear from 0 to 999.9 s || U || S
Time Constant20 ms +/- 1 ms for reference change
Maximum Output Voltage240 V
Base Load Current At High Overload4.2 A
Line Current10.2 A 100 V heavy duty) || 8.5 A 120 V heavy duty)
Speed Drive Output Frequency0.5-400 Hz
Transmission FrameRTU
With Safety Function Safe Speed Monitor (Ssm)false
Relay Output Number1
Transient Overtorque150-170 % of nominal motor torque depending on drive rating and type of motor
With Safety Function Safe Torque Off (Sto)false
Data Format8 bits, configurable odd, even or no parity
Connector Type1 RJ45
Analogue Output Number1
Physical Interface2-wire RS 485
Asynchronous Motor Control Profilequadratic voltage/frequency ratio || voltage/frequency ratio (V/f) || sensorless flux vector control
Insulationelectrical between power and control
Tightening Torque0.8 N.m
Continuous Output Current4.2 A 4 kHz
With Safety Function Safe Programmable Logicfalse
Brake Chopper Integratedfalse
Nominal Switching Frequency4 kHz
Quantity Per Setset of 1
Braking To Standstillby DC injection
Protection Typeline supply overvoltage || line supply undervoltage || overcurrent between output phases and earth || overheating protection || short-circuit between motor phases || against input phase loss in three-phase || thermal motor protection via the drive by continuous calculation of I²t
With Safety Function Safely Limited Speed (Sls)false
4 Quadrant Operation Possiblefalse
Relative Symmetric Network Frequency Tolerance5 %
Apparent Power2.0 kVA 240 V heavy duty)
Net Weight0.8 kg

Offer Sustainability

Mercury FreeYes
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Reach RegulationReference contains Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationX
Rohs Exemption InformationYes
Environmental DisclosureENVPEP090201EN
Sustainable Offer StatusGreen Premium product
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity ProfileENVEOLI100204EN

Environment

Product CertificationsNOM || CSA || C-tick || UL || GOST || RCM || KC
Electromagnetic Emissionradiated emissions environment 1 category C2 EN/IEC 61800-3 2...16 kHz shielded motor cable || conducted emissions with integrated EMC filter environment 1 category C1 EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m || conducted emissions with integrated EMC filter environment 1 category C2 EN/IEC 61800-3 2...12 kHz shielded motor cable <5 m || conducted emissions with integrated EMC filter environment 1 category C2 EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <10 m || conducted emissions with additional EMC filter environment 1 category C1 EN/IEC 61800-3 4...12 kHz shielded motor cable <20 m || conducted emissions with additional EMC filter environment 1 category C2 EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m || conducted emissions with additional EMC filter environment 2 category C3 EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m
Maximum Acceleration Under Shock Impact (During Operation)150 m/s² at 11 ms
Pollution Degree2
Electromagnetic Compatibilityelectrical fast transient/burst immunity test level 4 EN/IEC 61000-4-4 || electrostatic discharge immunity test level 3 EN/IEC 61000-4-2 || immunity to conducted disturbances level 3 EN/IEC 61000-4-6 || radiated radio-frequency electromagnetic field immunity test level 3 EN/IEC 61000-4-3 || surge immunity test level 3 EN/IEC 61000-4-5 || voltage dips and interruptions immunity test EN/IEC 61000-4-11
Ambient Air Temperature For Operation-10-40 °C without derating || 40-60 °C with current derating 2.2 % per °C
MarkingCE
Maximum Acceleration Under Vibrational Stress (During Operation)10 m/s² at 13...200 Hz
Noise Level0 dB
Ambient Air Temperature For Storage-25-70 °C
Relative Humidity5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Maximum Deflection Under Vibratory Load (During Operation)1.5 mm at 2...13 Hz
Assembly Stylewith heat sink
Operating Positionvertical +/- 10 degree
Ambient Air Transport Temperature-25-70 °C
StandardsUL 508C || UL 618000-5-1 || EN/IEC 61800-5-1 || EN/IEC 61800-3
Vibration Resistance1 gn 13-200 Hz)EN/IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz) - drive unmounted on symmetrical DIN rail - EN/IEC 60068-2-6
Shock Resistance15 gn 11 ms EN/IEC 60068-2-27
Regulation Loopadjustable PID regulator
Operating Altitude> 3280.84...6561.68 ft (> 1000...2000 m) with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Overvoltage Categoryclass III
Environmental Class (During Operation)class 3C3 according to IEC 60721-3-3 || class 3S2 according to IEC 60721-3-3

Documentazione


Spesso acquistati assieme


Altri articoli da Schneider Electric

Richiedi un preventivo