variable speed drive ATV212 - 37kW - 50hp - 480V - 3ph - EMC - IP21

Produttore:
Schneider Electric
Schneider%20electric

9a6e0957dc9ace472449c4d0ffbce81085f1c95e medium
Prezzo (IVA esclusa)
€ 5023.12
Codice Nuova Elva
ATV212HD37N4
Codice produttore
ATV212HD37N4
Disponibilità
Invia RdO

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 37kW / 50hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 38.1kg and its dimensions are, 240mm wide, 550mm high, 244mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet. It is eco-friendly and complies with directives such as RoHS, WEEE, etc.relating to environmental protection.

Specifications

CertificationsC-tick
Depth244 mm
Height550 mm
Number of Phases3
StandardEN 55011 Class A Group 1
Storage Temperature-25-70 °C
Warranty Length18 months
Width240 mm

Specifications

Product Destinationasynchronous motors
Supply Voltage Limits323-528 V
Product Specific Applicationpumps and fans in HVAC
Emc FilterClass C2 EMC filter integrated
Maximum Horse Power Rating50 hp
Device Short NameATV212
Supply Frequency50...60 Hz - 5...5 %
Range Of ProductAltivar 212
Product Or Component Typevariable speed drive
Ip Degree Of ProtectionIP21
Motor Power Kw37 kW
Phase3 phase
Line Current68.9 A 380 V || 54.4 A 480 V
[Us] Rated Supply Voltage380...480 V - 15...10 %
Communication Port ProtocolMETASYS N2 || BACnet || Modbus || APOGEE FLN || LonWorks

Contractual warranty

Warranty18 months

Complementary

Prospective Line Isc22 kA
Discrete Output Typeconfigurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
Transmission FrameRTU
Torque Accuracy+/- 15 %
Asynchronous Motor Control Profileflux vector control without sensor, standard || voltage/frequency ratio, 5 points || voltage/frequency ratio, 2 points || voltage/frequency ratio - Energy Saving, quadratic U/f || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Maximum Switching Current5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Communication Serviceread holding registers (03) 2 words maximum || monitoring inhibitable || write single register (06) || write multiple registers (16) 2 words maximum || time out setting from 0.1 to 100 s || read device identification (43)
Transient Overtorque120-120 % of nominal motor torque +/- 10 % 60 s
Insulation Resistance>= 1 mOhm 500 V DC for 1 minute
Response TimeFM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
Data Format8 bits, 1 stop, odd even or no configurable parity
Electrical ConnectionVIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 50-50 mm² / AWG 1/0
Apparent Power52 kVA 380 V
Dielectric Strength3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
Power Range30-50 kW 380-440 V 3 phase || 30-50 kW 480-500 V 3 phase
Type Of Polarizationno impedance
Frequency Resolutiondisplay unit 0.1 Hz || analog input 0.024/50 Hz
Accuracy+/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
Switching Frequency6...16 kHz adjustable || 8...16 kHz with derating factor
Maximum Transient Current86.9 A 60 s
Connector Type1 open style || 1 RJ45
Analogue Input Number2
Network Frequency47.5...63 Hz
Functionalitymid
Motor Slip Compensationnot available in voltage/frequency ratio motor control || automatic whatever the load || adjustable
Motor Starter Typevariable speed drive
Discrete Output Number2
Minimum Switching Current3 mA 24 V DC configurable relay logic
Analogue Output Number1
Physical Interface2-wire RS 485
Power Dissipation In W976 W
Continuous Output Current79 A 380 V || 79 A 460 V
Number Of Addresses1-247
Discrete Input Logicpositive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Tightening Torque0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 24 N.m, 212 lb.in L1/R, L2/S, L3/T)
Discrete Input TypeF programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
Speed Range1-10
Isolationelectrical between power and control
Local Signallingfor DC bus energized 1 LED (red)
Linearity ErrorVIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
Specific ApplicationHVAC
Output Voltage<= power supply voltage
Nominal Switching Frequency8 kHz
Width240 mm
Type Of Cablewithout mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
Transmission Rate9600 bps or 19200 bps
Braking To Standstillby DC injection
Air Flow334 m3/h
Depth244 mm
Protection Typeoverheating protection drive || line supply undervoltage drive || against input phase loss drive || thermal protection motor || motor phase break motor || with PTC probes motor || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit drive || against exceeding limit speed drive || line supply overvoltage and undervoltage drive
Supplyinternal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
Analogue Input TypeVIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Discrete And Process Manufacturingbuilding - HVAC compressor for scroll || building - HVAC fan || building - HVAC pump
Sampling Duration2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
Speed Accuracy+/- 10 % of nominal slip 0.2 Tn to Tn
Height550 mm
Option Cardcommunication card LonWorks
Acceleration And Deceleration Rampslinear adjustable separately from 0.01 to 3200 s || automatic based on the load
Analogue Output TypeFM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Speed Drive Output Frequency0.5-200 Hz

Offer Sustainability

Rohs Exemption InformationYes
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Mercury FreeYes
Environmental DisclosureENVPEP110404EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationX
Circularity ProfileENVEOLI110402EN

Environment

Product CertificationsUL || NOM 117 || C-tick || CSA
Pollution Degree3 IEC 61800-5-1
Regulation Loopadjustable PI regulator
Ambient Air Temperature For Storage-25-70 °C
Relative Humidity5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Assembly Stylewith heat sink
Ip Degree Of ProtectionIP20 on upper part without blanking plate on cover EN/IEC 61800-5-1 || IP20 on upper part without blanking plate on cover EN/IEC 60529 || IP21 EN/IEC 61800-5-1 || IP21 EN/IEC 60529 || IP41 on upper part EN/IEC 61800-5-1 || IP41 on upper part EN/IEC 60529
Operating Altitude3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Operating Positionvertical +/- 10 degree
StandardsIEC 61800-3 environments 2 category C1 || IEC 61800-3 environments 1 category C3 || IEC 61800-3 category C3 || IEC 61800-3 category C2 || EN 61800-3 || IEC 61800-3 environments 1 category C1 || IEC 61800-5-1 || EN 61800-3 environments 1 category C1 || EN 61800-3 category C3 || IEC 61800-3 environments 2 category C2 || EN 61800-3 category C2 || EN 61800-3 environments 2 category C1 || IEC 61800-3 || EN 61800-3 environments 1 category C3 || UL Type 1 || IEC 61800-3 environments 2 category C3 || IEC 61800-3 environments 1 category C2 || EN 55011 class A group 1 || EN 61800-5-1 || EN 61800-3 environments 1 category C2 || EN 61800-3 environments 2 category C3 || EN 61800-3 environments 2 category C2
Electromagnetic Compatibilityelectrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6 || voltage dips and interruptions immunity test IEC 61000-4-11
Ambient Air Temperature For Operation-10-40 °C without derating) || 40-50 °C with derating factor)
Shock Resistance15 gn 11 ms IEC 60068-2-27
Environmental Characteristicclasses 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
MarkingCE
Vibration Resistance1.5 mm 3-13 Hz)EN/IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
Noise Level64 dB 86/188/EEC

Documentazione