brushless DC motor, Lexium ILA ILE ILS, 24..36 V, CANopen DS301 interface, L = 174mm, 24:1
- Produttore:
- Schneider Electric
- Codice Nuova Elva
- ILE1F661PC1A5
- Codice produttore
- ILE1F661PC1A5
- Disponibilità
- Tempo di consegna standard: 23 giorni
Specifications
Certifications | CUL |
---|---|
Current | 5500 mA |
Length | 229 mm |
Mounting Hole Size | 4.4 mm |
Net Weight | 2.3 kg |
Number of Holes | 2 |
Number of Phases | 1 |
Number of Poles | 6 |
Standard | EN 50347 |
Storage Temperature | -25-70 °C |
Warranty Length | 18 months |
Specifications | |
Range Of Product | Lexium integrated drive |
[Us] Rated Supply Voltage | 36 V || 24 V |
Communication Interface | CANopen DS301, Integrated |
Gear Box Type | worm gear, 2 stages |
Motor Type | brushless DC motor |
Nominal Speed | 168 rpm 24 V || 168 rpm 36 V |
Electrical Connection | industrial connector |
Nominal Torque | 2.5 N.m 24 V || 3.5 N.m 36 V |
Device Short Name | ILE |
Reduction Ratio | 24:1 (525:22) |
Network Type | DC |
Winding Type | medium speed of rotation and medium torque |
Number Of Motor Poles | 6 |
Holding Brake | without |
Product Or Component Type | motion integrated drive |
Phase | single phase |
Length | 229 mm |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Current Consumption | 7000 mA peak || 5500 mA maximum continuous |
Second Shaft | without second shaft end |
Marking | CE |
Net Weight | 2.3 kg |
Voltage State 0 Guaranteed | -3...4.5 V |
Centring Collar Diameter | 36 mm |
Motor Flange Size | 66 mm |
Maximum Torsional Backlash | 1.5 ° |
Peak Stall Torque | 3.74 N.m 24 V || 5.18 N.m 36 V |
Number Of Mounting Holes | 2 |
Nominal Output Power | 45 W 24 V || 61 W 36 V |
Maximum Mechanical Speed | 186 rpm |
Discrete Output Voltage | 23...25 V |
Supply Voltage Limits | 18-40 V |
Mounting Holes Diameter | 4.4 mm |
Speed Feedback Resolution | 12 points/turn motor || 1.26° gearbox output |
Maximum Supply Current | 5.1 A 36 V || 0.1 A power stage disabled) || 6.8 A 24 V |
Detent Torque | 2.9 N.m |
Type Of Cooling | natural convection |
Service Life In Hours | 3000 h bearing |
Shaft End | hole |
Feedback Type | BLDC encoder |
Maximum Switching Current | 100 mA per output || 200 mA total |
Protection Type | safe torque off || overload of output voltage || short circuit of the output voltage |
Transmission Rate | 50, 100, 125, 250, 500, 800 and 1000 kbauds |
Accuracy Error | +/- 1 point |
Input/Output Type | 4 signals (each be used as input or output) |
Maximum Axial Force Fa | 80 N |
Associated Fuse Rating | 10 A |
Voltage State 1 Guaranteed | 15...30 V |
Maximum Radial Force Fr | 200 N |
Mounting Support | flange |
Number Of Motor Stacks | 1 |
Rotor Inertia | 90 kg.cm² |
Continuous Stall Torque | 4.2 N.m |
Discrete Input Current | 10-10 mA at 24 V on/STO_A safety input || 3-3 mA at 24 V on/STO_B safety input || 2-2 mA at 24 V 24 V signal interface |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Circularity Profile | ENVEOLI1411012EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1411012EN |
Sustainable Offer Status | Green Premium product |
Pvc Free | Yes |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Environment | |
Product Certifications | TÜV || cUL || UL |
Operating Altitude | <= 3280.84 ft (1000 m) without derating |
Standards | IEC 61800-3, Ed 2 || EN/IEC 61800-3 || EN 61800-3:2001, second environment || IEC 60072-1 || EN 50347 || EN 61800-3 : 2001-02 || EN/IEC 50178 |
Ambient Air Temperature For Operation | 50-65 °C with power derating of 2 % per °C) || 0-50 °C without derating) |
Shock Resistance | 150 m/s² 1000 shocks EN/IEC 60068-2-29 |
Vibration Resistance | 20 m/s² 10-500 Hz) 10 cycles EN/IEC 60068-2-6 |
Permissible Ambient Air Temperature Around The Device | 105 °C power amplifier || 110 °C motor |
Ambient Air Temperature For Storage | -25-70 °C |
Relative Humidity | 15-85 % without condensation |
Ip Degree Of Protection | shaft bushing IP41 EN/IEC 60034-5 || total except shaft bushing IP54 EN/IEC 60034-5 |