Circuit breaker, PowerPacT J, 200A, 3 pole, 600VAC, 18kA, lugs, thermal magnetic, 80%

Produttore:
Schneider Electric
Schneider electric

Dec29d2fa02c6e78f158d7d941c5ff33efd4bdaa medium
Prezzo (IVA esclusa)
€ 4186.80
Codice Nuova Elva
JGL36200
Codice produttore
JGL36200
Disponibilità
Invia RdO

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT J, 200A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Specifications

CertificationsCSA
Depth86 mm
Height191 mm
Line Rated Current200-200 A
Mounting TypeUnit Mount Lug)
Net Weight2.4 kg
StandardCSA
Storage Temperature-50-85 °C
Strip Length25 mm
Trip Point2000-2000 A
Warranty Length18 months
Width104 mm

Specifications

Product Or Component Typecircuit breaker
Product NamePowerPact J
RangePowerPact
Device Applicationdistribution

Contractual warranty

Warranty18 months

Complementary

Mounting Modeunit mount lug)
Breaking Capacity CodeG
Magnetic Tripping Current2000-2000 A
Local Signallingswitched off (OFF) 1 trip indicator green)
Number Of Slots2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Electrical Connectionlugs line || lugs load
Mounting Height4.5 in
Net Weight2.4 kg
[Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947-2
Magnetic Hold Current1000 A
Control Typetoggle
Network Frequency50/60 Hz
Circuit Breaker ApplicationHACR rated
Wire Stripping Length25 mm
Utilisation Categorycategory A
Line Rated Current200-200 A
Long Time Pick-Up Adjustment Range0.25...1 x In
Continuous Current Rating80 %
Breaking Capacity65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
[Ui] Rated Insulation Voltage750 V IEC 60947-2
Suitability For Isolationyes IEC 60947-2
Communication InterfaceModbus || Ethernet
Terminal IdentifierAL250JD
Poles Description3P
Protection Typeoverload protection || short-circuit protection
Awg GaugeAWG 3/0...350 kcmil aluminium/copper terminals
Width104 mm
Depth86 mm
Phase ConnectionABC
[Ics] Rated Service Breaking Capacity65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Trip Unit Technologythermal-magnetic
Height191 mm
[Ue] Rated Operational Voltage600 V AC 50/60 Hz IEC 60947-3
Tightening Torque25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
Mounting Supportlug

Offer Sustainability

Rohs Exemption InformationYes
Eu Rohs DirectiveCompliant
Mercury FreeYes
Environmental DisclosureENVPEP2206031EN
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs RegulationProduct out of China RoHS scope. Substance declaration for your information.
Circularity ProfileENVEOLI2206031EN

Environment

Ambient Air Temperature For Operation-2-70 °C
StandardsUL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Product CertificationsUL || CSA || NOM
Ip Degree Of Protectionfront cover IP40
Pollution Degree3 IEC 60947-1
Ambient Air Temperature For Storage-50-85 °C
Quality LabelsCE
Operating Altitude< 6561.68 ft (2000 m) without derating || 5000 m with derating

Documentazione