TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 48 V AC coil

Produttore:
Schneider Electric
Schneider electric

90e132495dfdc56b2ce565f712010abaaacbc6a7 medium
Prezzo (IVA esclusa)
€ 134.95
Codice Nuova Elva
LC2D12E7
Codice produttore
LC2D12E7
Disponibilità
Invia RdO

LC2D12E7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 12A AC-3 5.5kW@400V, it includes a 48V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D12E7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 5.5kW@400V. It includes a 48V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 48V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 12A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.

Specifications

CertificationsBV
Contact Configuration1 NO + 1 NC
Depth86 mm
Height77 mm
Impedance2.5 MOhm - Ith 25 A 50 Hz Power Circuit
Net Weight0.697 kg
StandardCSA C22.2 No 14
Storage Temperature-60-80 °C
Warranty Length18 months
Width90 mm

Specifications

Product CertificationsDNV || CSA || CCC || UL || GL || LROS (Lloyds register of shipping) || BV || RINA || GOST || UKCA
Control Circuit TypeAC 50/60 Hz
StandardsCSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Applicationresistive load || motor control
Rated Breaking Capacity250 A 440 V power circuit IEC 60947
Product Or Component Typereversing contactor
Irms Rated Making Capacity250 A 440 V power circuit IEC 60947 || 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1
Product NameTeSys D || TeSys Deca
Associated Fuse Rating10 A gG signalling circuit IEC 60947-5-1 || 40 A gG <= 690 V type 1 power circuit || 25 A gG <= 690 V type 2 power circuit
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Interlocking Typemechanical
Connections - Terminalspower circuit screw clamp terminals 1 1-4 mm²flexible without cable end || power circuit screw clamp terminals 2 1-4 mm²flexible without cable end || power circuit screw clamp terminals 1 1-4 mm²flexible with cable end || power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || power circuit screw clamp terminals 1 1-4 mm²solid || power circuit screw clamp terminals 2 1-4 mm²solid || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid || control circuit screw clamp terminals 2 1-4 mm²solid
RangeTeSys || TeSys Deca
Pole Contact Composition3 NO
Device Presentationpreassembled with reversing power busbar
Utilisation CategoryAC-1 || AC-3
[Ie] Rated Operational Current25 A 60 °C) <= 440 V AC AC-1 power circuit || 12 A 60 °C) <= 440 V AC AC-3 power circuit
Maximum Operating Rate3600 cyc/h 60 °C
Tightening Torquepower circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 2.5 N.m screw clamp terminals pozidriv No 2
Electrical Durability2 Mcycles 12 A AC-3 <= 440 V || 0.8 Mcycles 25 A AC-1 <= 440 V
Mechanical Durability15 Mcycles
[Uc] Control Circuit Voltage48 V AC 50/60 Hz
Poles Description3P
Operating Time12...22 ms closing || 4...19 ms opening
Overvoltage CategoryIII
Motor Power Kw3 kW 220...230 V AC 50 Hz || 5.5 kW 380...400 V AC 50 Hz || 5.5 kW 415...440 V AC 50 Hz || 7.5 kW 500 V AC 50 Hz || 7.5 kW 660...690 V AC 50 Hz
Maximum Horse Power Rating1 hp 115 V at AC 60 Hz for 1 phase || 2 hp 230/240 V at AC 60 Hz for 1 phase || 3 hp 200/208 V at AC 60 Hz for 3 phase || 3 hp 230/240 V at AC 60 Hz for 3 phase || 7.5 hp 460/480 V at AC 60 Hz for 3 phase || 10 hp 575/600 V at AC 60 Hz for 3 phase
[Ui] Rated Insulation Voltagepower circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
Device Short NameLC2D
[Icw] Rated Short-Time Withstand Current30 A 40 °C - 10 min power circuit || 61 A 40 °C - 1 min power circuit || 105 A 40 °C - 10 s power circuit || 210 A 40 °C - 1 s power circuit || 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit
Protective Coverwith
[Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Power Dissipation Per Pole1.56 W AC-1 || 0.36 W AC-3
Average Impedance2.5 mOhm - Ith 25 A 50 Hz power circuit
Auxiliary Contact Composition1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current10 A 60 °C signalling circuit || 25 A 60 °C power circuit
Mounting Supportplate || rail

Contractual warranty

Warranty18 months

Complementary

Non-Overlap Time1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Hold-In Power Consumption In Va7.5-7.5 VA 60 Hz 0.3 20 °C) || 7-7 VA 50 Hz 0.3 20 °C)
Heat Dissipation2-3 W 50/60 Hz
Minimum Switching Current5 mA signalling circuit
Control Circuit Voltage Limits0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60 °C operational AC 50 Hz || 0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 50/60 Hz
Insulation Resistance> 10 MOhm signalling circuit
Inrush Power In Va70-70 VA 60 Hz 0.75 20 °C) || 70-70 VA 50 Hz 0.75 20 °C)
Coil Technologywithout built-in suppressor module
Minimum Switching Voltage17 V signalling circuit
Signalling Circuit Frequency25...400 Hz
Auxiliary Contacts Typemechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1

Offer Sustainability

Rohs Exemption InformationYes
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationPro-active China RoHS declaration (out of China RoHS legal scope)
Circularity ProfileENVEOLI1501004
Eu Rohs DirectiveCompliant
Mercury FreeYes
Environmental DisclosureENVPEP1501004
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Toxic Heavy Metal FreeYes
Reach RegulationFree of Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of SvhcYes

Environment

Mechanical Robustnessvibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Ip Degree Of ProtectionIP20 front face IEC 60529
Operating Altitude0...9842.52 ft (0...3000 m)
Fire Resistance850 °C IEC 60695-2-1
Width90 mm
Depth86 mm
Ambient Air Temperature For Operation-40-60 °C || 60-70 °C with derating
Height77 mm
Climatic WithstandIACS E10 || IEC 60947-1 Annex Q category D
Pollution Degree3
Net Weight0.697 kg
Flame RetardanceV1 conforming to UL 94
Ambient Air Temperature For Storage-60-80 °C
Protective TreatmentTH IEC 60068-2-30

Documentazione


Spesso acquistati assieme


Altri articoli da Schneider Electric

Richiedi un preventivo