Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 9A, 1 NO aux, 24VDC coil
- Produttore:
- Schneider Electric
- Prezzo (IVA esclusa)
- € 53.55
- Codice Nuova Elva
- LP4K0910BW3
- Codice produttore
- LP4K0910BW3
- Disponibilità
- 2 in stock
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides a low consumption 24V DC coil with transient suppressor module, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Specifications
Certifications | CB Scheme |
---|---|
Contact Configuration | 1 NO |
Depth | 57 mm |
Height | 58 mm |
Impedance | 3 MOhm - Ith 20 A 50 Hz Power Circuit |
Net Weight | 0.235 kg |
Standard | CSA C22.2 No 60947-4-1 |
Storage Temperature | -50-80 °C |
Warranty Length | 18 months |
Width | 45 mm |
Specifications | |
Auxiliary Contact Composition | 1 NO |
Device Short Name | LP4K |
Range Of Product | TeSys K |
Contactor Application | resistive load || motor control |
Product Or Component Type | contactor |
Range | TeSys |
Pole Contact Composition | 3 NO |
Utilisation Category | AC-3 || AC-4 || AC-1 || AC-3e |
[Ie] Rated Operational Current | 20 A 50 °C) <= 440 V AC AC-1 power circuit || 9 A<= 440 V AC AC-3 power circuit || 16 A 70 °C) 690 V AC AC-1 power circuit || 9 A<= 440 V AC AC-3e power circuit |
Poles Description | 3P |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Minimum Switching Current | 5 mA signalling circuit |
Insulation Resistance | > 10 MOhm signalling circuit |
Rated Breaking Capacity | 110 A 415 V IEC 60947 || 110 A 440 V IEC 60947 || 80 A 500 V IEC 60947 || 110 A 220...230 V IEC 60947 || 110 A 380...400 V IEC 60947 || 70 A 660...690 V IEC 60947 |
Irms Rated Making Capacity | 110 A AC power circuit NF C 63-110 || 110 A AC power circuit IEC 60947 || 110 A AC signalling circuit IEC 60947 |
Associated Fuse Rating | 25 A gG <= 440 V power circuit || 25 A aM power circuit || 10 A gG signalling circuit IEC 60947 || 10 A gG signalling circuit VDE 0660 |
Net Weight | 0.235 kg |
[Uimp] Rated Impulse Withstand Voltage | 8 kV |
Coil Technology | built-in bidirectional peak limiting diode suppressor |
Flame Retardance | V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102 |
Minimum Switching Voltage | 17 V signalling circuit |
Maximum Operating Rate | 3600 cyc/h |
[Ue] Rated Operational Voltage | power circuit 690 V AC 50/60 Hz || signalling circuit <= 690 V AC 50/60 Hz |
Inrush Power In W | 1.8-1.8 W 20 °C) |
Mechanical Durability | 30 Mcycles |
Auxiliary Contacts Type | instantaneous 1 NO |
Operating Time | 10...20 ms coil de-energisation and NO opening || 30...40 ms coil energisation and NO closing |
Width | 45 mm |
Tightening Torque | 0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2 |
Overvoltage Category | III |
Depth | 57 mm |
[Ui] Rated Insulation Voltage | power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-5-1 || signalling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || signalling circuit 600 V CSA C22.2 No 14 |
Height | 58 mm |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz power circuit |
Control Circuit Voltage Limits | operational 0.7...1.30 Uc 50 °C) || drop-out 0.1...0.7 Uc 50 °C) |
[Ith] Conventional Free Air Thermal Current | 20 A 50 °C power circuit || 10 A 50 °C signalling circuit |
Mounting Support | plate || rail |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Hold-In Power Consumption In W | 1.8-1.8 W 20 °C |
Offer Sustainability | |
Rohs Exemption Information | Yes |
China Rohs Regulation | Pro-active China RoHS declaration (out of China RoHS legal scope) |
Circularity Profile | ENVEOLI1503003EN |
Eu Rohs Directive | Compliant |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1503003EN |
Sustainable Offer Status | Green Premium product |
Toxic Heavy Metal Free | Yes |
Reach Regulation | Free of Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Reach Free Of Svhc | Yes |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Environment | |
Product Certifications | CB Scheme || CCC || UL || CSA || EAC || CE || UKCA |
Ambient Air Temperature For Operation | -25-50 °C |
Standards | EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 |
Ambient Air Temperature For Storage | -50-80 °C |
Operating Altitude | 6561.68 ft (2000 m) without derating |