Reverser block for vertical mounting, TeSys Ultra, 38A/690V, coil 110-240VAC/DC
- Produttore:
- Schneider Electric
TeSys U reversing module for vertical mounting, for the constitution of TeSys U reversing starter controllers. It provides reverse power contacts, coil control with interlocking capabilities to be supplied with 110-240V AC / 110-220V DC. To be used with an advanced power base LUB120, LUB320, or LUB380 equipped with a Control Unit LUC*FU type. To be associated with an assembling connector LU9MR1C and a control terminal block LU9M1 to complete the vertical mounting. Green Premium compliant (RoHS/REACh).
Specifications
Certifications | ASEFA |
---|---|
Current | 1000 mA |
Depth | 105 mm |
Height | 80 mm |
Mounting Type | Direct Mounting |
Net Weight | 0.4 kg |
Standard | CSA C22.2 No 60947-4-1, With Phase Barrier |
Storage Temperature | -40-85 °C |
Warranty Length | 18 months |
Width | 45 mm |
Specifications | |
Device Mounting | direct mounting |
[Uc] Control Circuit Voltage | 110...240 V AC 50/60 Hz || 110...220 V DC |
Product Or Component Type | reverser block |
Current Consumption | 1000 mA 110...220 V DC I maximum while closing || 1000 mA 110...240 V AC I maximum while closing |
Range | TeSys |
[Ie] Rated Operational Current | 38 A |
Device Application | motor control |
Device Short Name | LU2MB |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Product Certifications | CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine |
[Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
Compatibility Code | LU2MB |
Operating Time | 150 ms with change of direction || 75 ms without change of direction |
Width | 45 mm |
Tightening Torque | control circuit 0.8-1.2 N.m flat 5 mm || control circuit 0.8-1.2 N.m Philips No 2 5 mm || power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm |
Depth | 105 mm |
Network Frequency | 40...60 Hz |
[Ue] Rated Operational Voltage | 690 V AC power circuit |
Height | 80 mm |
Connections - Terminals | control circuit screw clamp terminals 1 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) rigid || control circuit screw clamp terminals 2 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) rigid || power circuit screw clamp terminals 1 1-10 mm² 4 mm) rigid || power circuit screw clamp terminals 1 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² 4 mm) flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) rigid || power circuit screw clamp terminals 2 1.5-6 mm² 4 mm) flexible without cable end |
Net Weight | 0.4 kg |
Fixing Mode | plug-in |
[Uimp] Rated Impulse Withstand Voltage | 6 kVIEC 60947-6-2 |
Inrush Restraint Duration | 25 ms AC || 15 ms DC |
Standards | EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information. |
Eu Rohs Directive | Compliant |
Environment | |
Ambient Air Temperature For Operation | -25-60 °C with LUCM || -25-70 °C with LUCA, LUCB, LUCC, LUCD |
Operating Altitude | 6561.68 ft (2000 m) |
Fire Resistance | 960 °C parts supporting live components IEC 60695-2-12 || 650 °C IEC 60695-2-12 |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Resistance To Radiated Fields | 10 V/m level 3 IEC 61000-4-3 |
Non-Dissipating Shock Wave | 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2 |
Shock Resistance | 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27 |
Vibration Resistance | 2 gn 5-300 Hz) power poles open IEC 60068-2-27 || 4 gn 5-300 Hz) power poles closed IEC 60068-2-27 |
Ambient Air Temperature For Storage | -40-85 °C |
Protective Treatment | TH IEC 60068 |
Ip Degree Of Protection | IP20 IEC 60947-1 front panel and wired terminals) || IP20 IEC 60947-1 other faces) || IP40 IEC 60947-1 front panel outside connection zone) |
Resistance To Electrostatic Discharge | 8 kV level 3, in open air IEC 61000-4-2 || 8 kV level 4, on contact IEC 61000-4-2 |