trip unit TM100D for ComPact NSX 100/160/250 circuit breakers, thermal magnetic, rating 100 A, 3 poles 3d
- Produttore:
- Schneider Electric
This TM100D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160/250 circuit breakers. This 100A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Specifications
Certifications | CCC |
---|---|
Standard | EN/IEC 60947-2 |
Storage Temperature | -50-85 °C |
Warranty Length | 18 months |
Specifications | |
Network Frequency | 50/60 Hz |
Range | ComPact |
Poles Description | 3P |
Range Compatibility | ComPact NSX100 || ComPact NSX160 || ComPact NSX250 |
Device Application | distribution |
Trip Unit Technology | thermal-magnetic |
Trip Unit Name | TM-D |
Range Of Product | ComPact NSX100...250 |
[Ue] Rated Operational Voltage | 690 V AC 50/60 Hz |
Trip Unit Protection Functions | LI |
Network Type | AC |
Protected Poles Description | 3t |
Product Or Component Type | trip unit |
Protection Type | L : for overload protection (thermal) || I : for short-circuit protection (magnetic) |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Earth-Leakage Protection | without |
Long Time Delay Adjustment Type | fixed |
[Tr] Long-Time Delay Adjustment Range | 120-400 s 1.5 x In || 15-15 s 6 x Ir |
Short-Time Delay Adjustment Type | fixed |
Long Time Pick-Up Adjustment Type Ir | adjustable |
Long Time Pick-Up Adjustment Range | 0.7...1 x In |
[Isd] Short-Time Pick-Up Adjustment Range | 800 A |
Short-Time Pick-Up Adjustment Type Isd | fixed |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1702004EN |
Sustainable Offer Status | Green Premium product |
California Proposition 65 | WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information. |
Circularity Profile | ENVEOLI1702004EN |
Eu Rohs Directive | Compliant |
Environment | |
Product Certifications | EAC || CCC || Marine |
Ambient Air Temperature For Operation | -25-70 °C |
Standards | UL 508 || EN/IEC 60947-2 |
Ambient Air Temperature For Storage | -50-85 °C |