Miniature circuit breaker (MCB), Multi9 C60SP, 3P, 16A, C curve, 10kA (UL1077), 10kA (IEC/EN 60947-2)

Produttore:
Schneider Electric
Schneider electric

C71988afa510b2e9041c193112cf5fa46f0a9860 medium
Prezzo (IVA esclusa)
€ 99.36
Codice Nuova Elva
M9F22316
Codice produttore
M9F22316
Disponibilità
Invia RdO

This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles, 16A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 6 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 54mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.

Specifications

CertificationsCCC
ColorGray
Depth72 mm
Height81 mm
Line Rated Current16 A
Mounting TypeClip-On
StandardCSA C22.2 No 235
Storage Temperature-40-80 °C
Strip Length14 mm
Width54 mm

Specifications

Line Rated Current16 A 25 °C EN/IEC 60947-2
Breaking Capacity14 kA AIR 240 V AC UL 1077 || 14 kA AIR 240 V AC CSA C22.2 No 235 || 10 kA AIR 480Y/277 V AC UL 1077 || 10 kA AIR 480Y/277 V AC CSA C22.2 No 235 || 6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA Icu 240 V AC GB 14048.2
Suitability For Isolationyes EN/IEC 60947-2
Poles Description3P
Device Applicationdistribution
Device Short NameC60SP
Trip Unit Technologythermal-magnetic
Curve CodeC
Number Of Protected Poles3
Network TypeAC
StandardsEN/IEC 60947-2 || GB 14048.2 || UL 1077 || CSA C22.2 No 235
Product CertificationsIEC || CCC || UR || CSA
Product Or Component Typeminiature circuit-breaker
Product NameMulti9 C60
RangeMulti9

Complementary

[Ics] Rated Service Breaking Capacity4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
[Ui] Rated Insulation Voltage500 V AC EN/IEC 60947-2
Mounting Modeclip-on
Electrical Durability10000 cycles
Mechanical Durability20000 cycles
Local SignallingON/OFF indication
[Uimp] Rated Impulse Withstand Voltage6 kVEN/IEC 60947-2
ColorGray
Width54 mm
Provision For Padlockingpadlockable
Depth72 mm
Height81 mm
Tightening Torque2.5-2.5 N.m top or bottom
Magnetic Tripping Limit8.5 x In +/- 20 % AC
[Ue] Rated Operational Voltage240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz
Contact Position Indicatoryes
Earth-Leakage Protectionwithout
Mounting SupportDIN rail
9 Mm Pitches6
Wire Stripping Length14 mm top or bottom
Control Typetoggle
Connections - Terminalstunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 8) - rigid || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible with ferrule || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP1304004
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationProduct out of China RoHS scope. Substance declaration for your information.
Eu Rohs DirectiveCompliant
Halogen Content PerformanceHalogen free product

Environment

Ambient Air Temperature For Operation-30-70 °C
Tropicalisation2 IEC 60068-1
Ip Degree Of ProtectionIP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
Pollution Degree3 EN/IEC 60947-2
Ambient Air Temperature For Storage-40-80 °C
Relative Humidity95-95 % 55-55 °C
Operating Altitude0...6561.68 ft (0...2000 m)

Documentazione


Altri articoli da Schneider Electric

Richiedi un preventivo