Terminal block, Linergy TR, spring type, feed through, 2 points, 35mm², blue, set of 50

Produttore:
Schneider Electric
Schneider electric

17596e6ec1d1ada185c2c0abec2d5798102fbfbb medium
Codice Nuova Elva
NSYTRR352BL
Codice produttore
NSYTRR352BL
Disponibilità
Invia RdO

Specifications

CertificationsCSA
ColorBlue
Height59 mm
Length100 mm
Line Rated Current115-115 A
MaterialPolyamide 6/6 Insulating Case
Mounting TypeClip-On
Net Weight42 g
Number of Terminations2
Strip Length25 mm
Width16 mm

Specifications

Terminal Block Typepassthrough
Quantity Per Setset of 50
ColorBlue
Device Short NameTRR
Accessory / Separate Part Categoryconnection accessory
Product Or Component Typeterminal block
Product NameLinergy TR
Length100 mm
RangeLinergy
Mounting Modeclip-on
Terminal Block Level1
Nominal Cross Section35 mm²

Complementary

Dielectric Loss0.01 at 1 MHz IEC 60250 || 0.01 at 1 MHz VDE 0303-T4
Flame RetardanceV0 0.8 mm UL 94
Wire Stripping Length25 mm
Resistivity10000 MΩ.m IEC 60093 || 10000 MΩ.m VDE 0303-T30
Dielectric Constant3.7 at 1 MHz
Materialpolyamide 6/6 insulating case
Surface Resistance1000 GΩ IEC 60093 || 1000 GΩ VDE 0303-T30
Width16 mm
Range CompatibilityPrisma G || Prisma P || Prisma PH || Prisma Pack || Spacial || Kaedra || Pragma || TeSys
Product CompatibilitySpacial enclosures
Line Rated Current125-125 A EN/IEC 60947-7-1 || 115-115 A CSA || 115-115 A cURus
Height59 mm
Creep Resistance500 CTI (> 400 kB) IEC 60093 || 500 CTI (> 400 kB) VDE 0303-T30
[Ue] Rated Operational Voltage1000 V EN/IEC 60947-7-1 || 600 V CSA || 600 V cURus
Number Of Terminals2
Cable Cross Section2.5-35 mm², flexible without cable end || 2.5-35 mm², solid
Connections - Terminals1 x spring terminal upstream || 1 x spring terminal downstream
Connection Positiontop
Number Of Measurement Input2
Tool Typeconnection flat screwdriver || disconnection flat screwdriver
Net Weight42 g

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP1304013EN
Sustainable Offer StatusGreen Premium product
Toxic Heavy Metal FreeYes
Reach RegulationFree of Substances of Very High Concern above the threshold
Reach Free Of SvhcYes
China Rohs RegulationPro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsEAC || cURus || CSA
Ambient Air Temperature For Operation-40-130 °C IEC 60216-1 || -40-130 °C VDE 0304-T21
Dielectric Strength1000 V IEC 60243-1