Modular timing relay, Harmony, 0.7A, 1CO, 0,1s..100h, on delay, solid state output, 24..240V AC DC

Produttore:
Schneider Electric
Schneider electric

Fa8ea4c5d4b6464b5ffa6e00d65bfa42d50abaa8 medium
Prezzo (IVA esclusa)
€ 50.94
Codice Nuova Elva
RE17LAMW
Codice produttore
RE17LAMW
Disponibilità
Invia RdO

This Harmony RE17L timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 0.7A, is 17.5mm wide and can be supplied with 24V to 240V AC/DC. It also has 2 changeover contacts DPDT (double pole double throw). It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. 17.5mm width, same size as a 1-pole circuit breaker, to simplify your panel design. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0 0

Specifications

CertificationsCSA
Net Weight0.068 kg
Standard2004/108/EC
Storage Temperature-30-60 °C
Width17.5 mm

Specifications

Discrete Output Typesolid state
Range Of ProductHarmony Timer Relays
Product Or Component Typesingle function relay
Component NameRE17L
Time Delay Range1...10 s || 10...100 h || 6...60 s || 0.1...1 s || 1...10 min || 6...60 min || 1...10 h
Nominal Output Current0.7 A
Width17.5 mm
Time Delay Typepower on-delay

Complementary

Safety Reliability DataMTTFd = 353.8 years || B10d = 320000
MarkingCE
Voltage Range0.85...1.1 Us
Reset Time350 ms on de-energisation typical
Operating Rate In Hz10 Hz
Net Weight0.068 kg
Maximum Voltage Drop<4 V 3-wire || <8 V 2-wire
Mounting Positionany position in relation to normal vertical mounting plane
Voltage Drift+/- 0.2 %/V
Maximum Switching Voltage250 V AC/DC
Connections - Terminalsscrew terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
Setting Accuracy Of Time Delay+/- 10 % of full scale 25 °C IEC 61812-1
Functionalityon-delay timing
[Us] Rated Supply Voltage24...240 V AC/DC 50/60 Hz
Temperature Drift+/- 0.05 %/°C
Minimum Switching Current10 mA
Mounting Support35 mm DIN rail conforming to EN/IEC 60715
Maximum Output Current20 A
Compatibility CodeRE17
On-Load Factor100 %
Housing Materialself-extinguishing
Impulse Duration0.05 s typical
Creepage Distance4 kV/3 IEC 60664-1
Maximum Leakage Current5 mA
Time Delay TypeA
[Uimp] Rated Impulse Withstand Voltage5 kV 1.2/50 µs
Tightening Torque0.6-1 N.m IEC 60947-1
Electrical Durability100000000 cycles
Breaking Capacity0.5 A AC/DC UL || 0.7 A AC/DC 20 °C
Supply Frequency50...60 Hz +/- 5 %
Repeat Accuracy+/- 0.5 % IEC 61812-1
Maximum Delay Response100 ms
Control Typeselector switch front panel
Insulation Resistance100 MOhm 500 V DC IEC 60664-1
Maximum Power Consumption In W1.5 W 240 V DC
Power Consumption In Va0-3 VA 240 V AC
Dielectric Strength2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP121117EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs RegulationX
Circularity ProfileENVEOLI121113EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsGL || CSA || cULus
Relative Humidity93-93 % without condensation IEC 60068-2-30
Derating Factor5 mA/°C
Ambient Air Temperature For Operation-20-60 °C
Standards2004/108/EC || EN 61000-6-1 || 2006/95/EC || EN 61000-6-3 || EN 61000-6-2 || IEC 61812-1 || EN 61000-6-4
Immunity To Microbreaks20 ms
Electromagnetic Compatibilityelectrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2 || electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2 || susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4 || 1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5 || 1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5 || conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6 || voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11 || voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11 || conducted and radiated emissionsclass B EN 55022
Shock Resistance15 gn 11 ms IEC 60068-2-27
Vibration Resistance20 m/s² 10-150 Hz)IEC 60068-2-6
Ip Degree Of ProtectionIP20 IEC 60529 terminal block) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)
Ambient Air Temperature For Storage-30-60 °C

Documentazione


Spesso acquistati assieme


Altri articoli da Schneider Electric

Richiedi un preventivo