Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC
- Produttore:
- Schneider Electric
- Prezzo (IVA esclusa)
- € 61.43
- Codice Nuova Elva
- RE22R1AMR
- Codice produttore
- RE22R1AMR
- Disponibilità
- 2 in stock
This Harmony RE22 modular dual function timer can be set between 0.05 seconds and 300 hours, has an output rating of 8 amperes and it is 22.5 millimeters wide. It provides function A and function Aw and it is mountable on DIN rail. This modular dual function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Selectable timing range offers a one stop solution for your power management system. Dual function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
Specifications
Certifications | CCC |
---|---|
Input Voltage | 2.4 V |
Net Weight | 0.1 kg |
Standard | IEC 61812-1 |
Storage Temperature | -40-70 °C |
Width | 22.5 mm |
Specifications | |
Discrete Output Type | relay |
Range Of Product | Harmony Timer Relays |
Product Or Component Type | dual function relay |
Nominal Output Current | 8 A |
Device Short Name | RE22 |
Complementary | |
Power Consumption In W | 1.5 W 240 V DC |
Power Consumption In Va | 3-3 VA 240 V AC |
Switching Capacity In Va | 2000 VA |
Minimum Pulse Duration | 100 ms with load in parallel || 30 ms |
Maximum Switching Current | 8 A |
Voltage Range | 0.85...1.1 Us |
Net Weight | 0.1 kg |
Mounting Position | any position |
Voltage Drift | +/- 0.2 %/V |
Reset Time | 120 ms on de-energisation |
Maximum Switching Voltage | 250 V AC |
Safety Reliability Data | MTTFd = 308.2 years || B10d = 280000 |
Connections - Terminals | screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end |
[Us] Rated Supply Voltage | 24...240 V AC/DC 50/60 Hz |
Temperature Drift | +/- 0.05 %/°C |
Time Delay Range | 3...30 s || 30...300 s || 10...100 s || 0.05...1 s || 1...10 s || 30...300 h || 30...300 min || 0.3...3 s || 3...30 h || 3...30 min |
Minimum Switching Current | 10 mA 5 V DC |
Overvoltage Category | III IEC 60664-1 |
Input Voltage | <= 2.4 V |
Mounting Support | 35 mm DIN rail conforming to EN/IEC 60715 |
Electrical Durability | 100000 cycles, 8 A at 250 V, AC-1 || 100000 cycles, 2 A at 24 V, DC-1 |
Mechanical Durability | 10000000 cycles |
Contacts Type And Composition | 1 C/O timed contact, cadmium free |
Housing Material | self-extinguishing |
Status Led | Green LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED fast flashing)timing in progress and output relay de-energised || Yellow LED slow flashing)timing in progress and output relay energised |
[Uimp] Rated Impulse Withstand Voltage | 5 kV 1.2-50 µs IEC 60664-1 |
Width | 22.5 mm |
Time Delay Type | power on-delay |
Tightening Torque | 0.6-1 N.m IEC 60947-1 |
Supply Frequency | 50...60 Hz +/- 5 % |
Repeat Accuracy | +/- 0.5 % IEC 61812-1 |
Setting Accuracy Of Time Delay | +/- 10 % of full scale 25 °C IEC 61812-1 |
Creepage Distance | 4 kV/3 IEC 60664-1 |
Maximum Delay Response | 100 ms |
Control Type | rotary knob || diagnostic button |
Insulation Resistance | 100 MOhm 500 V DC IEC 60664-1 |
Immunity To Microbreaks | 10 ms |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1401008EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
China Rohs Regulation | X |
Circularity Profile | ENVEOLI1401008EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Product Certifications | CE || UL || GL || CCC || EAC || RCM || CSA |
Ambient Air Temperature For Storage | -40-70 °C |
Relative Humidity | 95-95 % 25-55 °C |
Ip Degree Of Protection | housing IP40 IEC 60529 || front face IP50 IEC 60529 || terminals IP20 IEC 60529 |
Ambient Air Temperature For Operation | -20-60 °C |
Standards | UL 508 || IEC 61812-1 |
Electromagnetic Compatibility | fast transients immunity test 1 kV capacitive connecting clip)level 3 IEC 61000-4-4 || surge immunity test 1 kV differential mode)level 3 IEC 61000-4-5 || surge immunity test 2 kV common mode)level 3 IEC 61000-4-5 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/m 80 MHz...1 GHz)level 3 IEC 61000-4-3 || conducted RF disturbances 10 V 0.15...80 MHz)level 3 IEC 61000-4-6 || fast transient bursts 2 kV direct contact)level 3 IEC 61000-4-4 || immunity to microbreaks and voltage drops 30 % 500 ms) IEC 61000-4-11 || immunity to microbreaks and voltage drops 100 % 20 ms) IEC 61000-4-11 |
Dielectric Strength | 2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1 |
Shock Resistance | 15 gn not operating 11 ms IEC 60068-2-27 || 5 gn in operation 11 ms IEC 60068-2-27 |
Vibration Resistance | 20 m/s² 10-150 Hz)IEC 60068-2-6 |
Pollution Degree | 3 IEC 60664-1 |
Directives | 2006/95/EC - low voltage directive || 2004/108/EC - electromagnetic compatibility |