Harmony, Modular 1-phase current control relay, 5 A, 2 CO, 0.15…15 A,, 24…240 V AC/DC

Produttore:
Schneider Electric
Schneider%20electric

76af9606b469d9cab599dd790c8069d0420f81b8 medium
Prezzo (IVA esclusa)
€ 128.34
Codice Nuova Elva
RM35JA32MW
Codice produttore
RM35JA32MW
Disponibilità
Invia RdO

This Harmony RM35-JA relay allows monitoring of current control in single phase networks. This modular multi function single phase current control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0

Specifications

CertificationsC-tick
Housing MaterialPlastic
Net Weight0.13 kg
Operating Cycles360
StandardEN/IEC 60255-6
Storage Temperature-40-70 °C
Warranty Length18 months
Width35 mm

Specifications

Minimum Switching Current10 mA 5 V DC
Relay Typecurrent control relay
Time Delay Typeadjustable 1...20 s, 0 + 10 % on energisation Ti || adjustable 0.3...30 s, 0 + 10 % on crossing the threshold Tt
Relay Monitored Parametersovercurrent or undercurrent detection
Maximum Power Consumption In Va3.5 VA AC
Maximum Switching Current5 A AC/DC
Range Of ProductHarmony Control Relays
Measurement Range0.15...1.5 A E1-M terminals || 0.5...5 A E2-M terminals || 1.5...15 A E3-M terminals || 150 mA...15 A current
Switching Capacity In Va1250 VA
Product Or Component Typecurrent control relay
Utilisation CategoryAC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1
Relay NameRM35JA
Contacts Type And Composition2 C/O

Contractual warranty

Warranty18 months

Complementary

[Us] Rated Supply Voltage24...240 V AC/DC 50/60 Hz +/- 10 %
Output Contacts2 C/O
Contacts Materialcadmium free
MarkingCE : EMC 89/336/EEC || CE : 73/23/EEC
Operating Positionany position without derating
Net Weight0.13 kg
Threshold Setting10...100 %
Maximum Switching Voltage250 V AC/DC
Reset Time1500 ms time delay
Connections - Terminalsscrew terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
[Ui] Rated Insulation Voltage250 V IEC 60664-1
Polarityno DC
Overvoltage CategoryIII IEC 60664-1
Supply Voltage Limits20.4-264 V AC/DC
Mounting Support35 mm symmetrical DIN rail conforming to EN/IEC 60715
Nominal Output Current5 A
Local Signallingfor power ON LED (green) || for relay ON LED (yellow)
Mechanical Durability30000000 cycles
Housing Materialself-extinguishing plastic
Resistance Across Terminals0.005 Ohm E3-M terminals || 0.015 Ohm E2-M terminals || 0.05 Ohm E1-M terminals
Control Circuit Frequency40...70 Hz +/- 10 %
Measurement Accuracy+/- 10 % of the full scale value
Safety Reliability DataMTTFd = 296.8 years || B10d = 270000
Width35 mm
Tightening Torque0.6-1 N.m IEC 60947-1
Maximum Power Consumption In W0.6 W DC
Electrical Durability100000 cycles
Run-Up Delay At Power-Up0.3 s
Repeat Accuracy+/- 0.5 % input and measurement circuit || +/- 2 % time delay
Maximum Measuring Cycle30 ms measurement cycle as true rms value
Control Circuit Voltage Limits15 % + 10 % Un
Hysteresis5-50 % threshold setting
Insulation Resistance> 500 MOhm 500 V DC between supply and relay output IEC 60255-5 || > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 || > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 || > 500 MOhm 500 V DC between supply and relay output IEC 60664-1 || > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5 || > 1 MOhm 500 V DC between supply and measurement IEC 60664-1
Measurement Error0.05 %/°C with temperature variation || 1 by volt over the whole range with voltage variation
Operating Rate<= 360 operations/hour full load

Offer Sustainability

Rohs Exemption InformationYes
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Mercury FreeYes
Environmental DisclosureENVPEP1504008EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationX
Circularity ProfileENVEOLI1504008EN

Environment

Product CertificationsGL || UL || GOST || C-tick || CSA
Ip Degree Of ProtectionIP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
Pollution Degree3 IEC 60664-1
Ambient Air Temperature For Storage-40-70 °C
Relative Humidity95-95 % 55-55 °C IEC 60068-2-30
StandardsEN/IEC 60255-6
Immunity To Microbreaks50 ms
Non-Dissipating Shock Wave4 kV IEC 60255-5 || 4 kV IEC 60664-1 || 4 kV IEC 61000-4-5
Dielectric Test Voltage2 kV AC 50 Hz, 1 min IEC 60255-5 || 2 kV AC 50 Hz, 1 min IEC 60664-1
Electromagnetic Compatibilityemission standard for industrial environments EN/IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || immunity for industrial environments NF EN/IEC 61000-6-2
Shock Resistance15 gn 11 ms IEC 60255-21-1
Ambient Air Temperature For Operation-20-50 °C
Vibration Resistance0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1

Documentazione


Spesso acquistati assieme


Altri articoli da Schneider Electric

Richiedi un preventivo