Modular 1 phaseVoltage control relay, Harmony, 5A, 2CO, range 1..100V, 24..240V AC DC

Produttore:
Schneider Electric
Schneider%20electric

B24d7b5f1fa85bbcf69d92046b7c672d54068831 medium
Prezzo (IVA esclusa)
€ 102.80
Codice Nuova Elva
RM35UA12MW
Codice produttore
RM35UA12MW
Disponibilità
Invia RdO

This Harmony RM35-U multi function control relay allows monitoring of voltage control. This modular multi function control relay is ideal for monitoring of electrical values and voltage variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0

Specifications

CertificationsC-tick
Housing MaterialPlastic
Net Weight0.08 kg
Operating Cycles360
StandardEN/IEC 60255-6
Storage Temperature-40-70 °C
Warranty Length18 months
Width35 mm

Specifications

Minimum Switching Current10 mA 5 V DC
Contacts Type And Composition2 C/O
Relay Typemultifunction voltage control relay
Time Delay Typeadjustable 0.3...30 s, 0 + 10 % on crossing the threshold
Relay Monitored Parametersovervoltage or undervoltage detection
Maximum Switching Current5 A AC/DC
Range Of ProductHarmony Control Relays
Measurement Range1...100 V voltage
Power Consumption In Va0-3.5 VA AC
Switching Capacity In Va1250 VA
Product Or Component Typevoltage control relay
Utilisation CategoryAC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1
Relay NameRM35UA

Contractual warranty

Warranty18 months

Complementary

[Us] Rated Supply Voltage24...240 V AC/DC 50/60 Hz +/- 10 %
Immunity To Microbreaks10 ms
Polaritynon reversible polarity on DC supply
Operating Positionany position without derating
Sensitivity Scale1...10 V E1-M terminals || 10...100 V E3-M terminals || 5...50 V E2-M terminals
Net Weight0.08 kg
Threshold Setting10...100 %
Maximum Switching Voltage250 V AC/DC
Reset Time1500 ms time delay
Run-Up Delay At Power-Up600 ms
Connections - Terminalsscrew terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...2 x 2.5 mm² AWG 24...AWG 12) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
Safety Reliability DataB10d = 290000 || MTTFd = 308.2 years
[Ui] Rated Insulation Voltage250 V IEC 60664-1 || 600 V IEC 60664-1
Overvoltage CategoryIII IEC 60664-1
Quality LabelsCE
Supply Voltage Limits20.4-264 V AC/DC
Mounting Support35 mm symmetrical DIN rail conforming to EN/IEC 60715
Nominal Output Current5 A
Local Signallingfor power ON LED (green) || for relay ON LED (yellow)
Mechanical Durability30000000 cycles
Compatibility CodeRM3
Housing Materialself-extinguishing plastic
Maximum Measuring Cycle30 ms measurement cycle as true rms value
Resistance Across Terminals110 mOhm E2-M terminals || 22 mOhm E1-M terminals || 220 mOhm E3-M terminals
Control Circuit Frequency40...70 Hz +/- 10 %
Measurement Accuracy+/- 10 % of the full scale value
Width35 mm
Tightening Torque0.6-1 N.m IEC 60947-1
Maximum Power Consumption In W0.6 W DC
Electrical Durability100000 cycles
Repeat Accuracy+/- 0.5 % input and measurement circuit || +/- 2 % time delay
Control Circuit Voltage Limits15 % + 10 % Un
Hysteresis5-50 % threshold setting
Insulation Resistance> 500 MOhm 500 V DC between supply and relay output IEC 60255-5 || > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 || > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 || > 500 MOhm 500 V DC between supply and relay output IEC 60664-1 || > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5 || > 1 MOhm 500 V DC between supply and measurement IEC 60664-1
Measurement Error+/- 0.05 %/°C with temperature variation || < 1 % over the whole range with voltage variation
Operating Rate<= 360 operations/hour full load
Output Contacts2 C/O

Offer Sustainability

Rohs Exemption InformationYes
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Mercury FreeYes
Environmental DisclosureENVPEP1504008EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationX
Circularity ProfileENVEOLI1504008EN

Environment

Product CertificationsGOST || C-tick || UL || GL || CSA
Pollution Degree3 IEC 60664-1
Directives73/23/EEC - low voltage directive || 89/336/EEC - electromagnetic compatibility
Ambient Air Temperature For Storage-40-70 °C
Relative Humidity95-95 % 55-55 °C IEC 60068-2-30
StandardsEN/IEC 60255-6
Non-Dissipating Shock Wave4 kV IEC 60255-5 || 4 kV IEC 60664-1 || 4 kV IEC 61000-4-5
Dielectric Test Voltage2 kV AC 50 Hz, 1 min IEC 60255-5 || 2 kV AC 50 Hz, 1 min IEC 60664-1
Electromagnetic Compatibilityemission standard for industrial environments EN/IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || immunity for industrial environments NF EN/IEC 61000-6-2
Shock Resistance5 gn IEC 60068-2-27
Ambient Air Temperature For Operation-20-50 °C
Vibration Resistance0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1
Ip Degree Of ProtectionIP20 IEC 60529 terminals) || IP30 IEC 60529 casing)