standard analog input kit STB - 2 I - 15 bits + sign
- Produttore:
- Schneider Electric
- Prezzo (IVA esclusa)
- € 331.39
- Codice Nuova Elva
- STBART0200K
- Codice produttore
- STBART0200K
- Disponibilità
- Tempo di consegna standard: 7 giorni
This product is part of the Modicon STB range, an offer of modular distributed I/O. This standard analogue input kit is an accessory kit of Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC). It has 2 analogue inputs with 15bit plus sign resolution. This product is compatible with most major fieldbus networks. It is an analogue input kit with a rated supply voltage of 24V DC and a current consumption of 30mA at 5V DC for logic bus. It is an IP20 rated product. It is suitable for packaging, bottling, assembly, distribution, textile, printing and semiconductor machines applications. This product is certified by FM Class 1 Division 2, ATEX category 3G, CE, UL, CSA and C-Tick. This kit is suitable for use with mounting base STBXBA1000 and power distribution module STBPDT3100/3105. The kit includes STBART0200 module, STBXTS1100, 6-terminal screw type connector, STBXBA1000 base and STBXTS2100, 6-terminal spring clamp connector. The Modicon STB distributed I/O solution is an open, modular input/output system that makes it possible to design automation islands managed by a master controller via a bus or communication network.
Specifications
Certifications | ATEX Cat 3G |
---|---|
Current | 30 mA |
Impedance | 10 mΩ |
Storage Temperature | -40-85 °C Without Derating |
Warranty Length | 18 months |
Specifications | |
Range Of Product | Modicon STB distributed I/O solution |
Type Of Filter | single low pass input filter 25 Hz |
Product Or Component Type | standard analog input kit |
Analogue Input Number | 2 |
Analogue Input Resolution | 15 bits + sign |
Kit Composition | STBART0200 module || STBXTS1100, 6-terminal screw type connector || STBXBA1000 base || STBXTS2100, 6-terminal spring clamp connector |
Analogue Input Type | voltage +/- 80 mV || thermocouple -200...+760 °C thermocouple J || thermocouple -270...+1000 °C thermocouple E || thermocouple -270...+1370 °C thermocouple K || thermocouple -270...+400 °C thermocouple T || thermocouple -50...+1665 °C thermocouple R || thermocouple -50...+1665 °C thermocouple S || temperature probe -100...+260 °C Cu 10 2, 3 or 4 wires IEC || temperature probe -100...+450 °C Pt 100 2, 3 or 4 wires US/JIS || temperature probe -100...+450 °C Pt 1000 2, 3 or 4 wires US/JIS || temperature probe -200...+850 °C Pt 100 2, 3 or 4 wires IEC || temperature probe -200...+850 °C Pt 1000 2, 3 or 4 wires IEC || temperature probe -60...+180 °C Ni 100 2, 3 or 4 wires IEC || temperature probe -60...+180 °C Ni 1000 2, 3 or 4 wires IEC || thermocouple +130...+1820 °C thermocouple B |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Insulation Between Channels And Logic Bus | 1500 V for 1 minute |
Marking | CE |
Fallback Status | state 0 basic NIMs || user configurable standard NIMs |
Conversion Time | 150 ms voltage 60 Hz || 400 ms thermocouple with external cold-junction compensation 50 Hz || 170 ms voltage 50 Hz || 180 ms temperature probe 60 Hz 2 or 4 wires || 200 ms temperature probe 50 Hz 2 or 4 wires || 210 ms thermocouple with internal cold-junction compensation 60 Hz || 230 ms thermocouple with internal cold-junction compensation 50 Hz || 300 ms temperature probe 60 Hz 3 wires || 340 ms temperature probe 50 Hz 3 wires || 360 ms thermocouple with external cold-junction compensation 60 Hz |
Addressing Requirement | 1 word for cold-junction compensation || 2 input words |
Absolute Accuracy Error | +/- 0.1 % of full scale 25 °C internal || +/- 0.15 % of full scale 25 °C external |
Maximum Wiring Resistance | 20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires || 500 Ohm Pt 1000 IEC/US/JIS 4 wires || 20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires || 20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires || 200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires || 200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires || 50 Ohm Cu 10 IEC/US/JIS 4 wires || 50 Ohm Ni 100 IEC/US/JIS 4 wires || 50 Ohm Pt 100 IEC/US/JIS 4 wires || 500 Ohm Ni 1000 IEC/US/JIS 4 wires |
Absolute Maximum Input | +/- 7.5 V DC |
Protection Type | short-circuit protection |
Overvoltage Category | II |
Product Compatibility | mounting base STBXBA1000 || power distribution module STBPDT3100/3105 |
Cold Swapping | yes |
[Us] Rated Supply Voltage | 24 V DC |
Measurement Accuracy | +/- 1 °C Ni 100 25 °C external || +/- 1.75 °C thermocouple K with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple R with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple S with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple T with external cold-junction compensation 25 °C || +/- 2 °C Pt 100 25 °C external || +/- 2 °C Pt 1000 25 °C external || +/- 2.85 °C thermocouple B with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple E with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple J with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple K with external cold-junction compensation 60 °C || +/- 1 °C Ni 100 25 °C internal || +/- 2.85 °C thermocouple R with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple S with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple T with external cold-junction compensation 60 °C || +/- 3.6 °C thermocouple R with internal cold-junction compensation 25 °C || +/- 4 °C Cu 10 25 °C external || +/- 4 °C Cu 10 25 °C internal || +/- 4 °C thermocouple K with internal cold-junction compensation 25 °C || +/- 4.1 °C thermocouple S with internal cold-junction compensation 25 °C || +/- 4.2 °C thermocouple R with internal cold-junction compensation 60 °C || +/- 4.4 °C thermocouple T with internal cold-junction compensation 25 °C || +/- 1 °C Ni 1000 25 °C external || +/- 4.6 °C thermocouple B with internal cold-junction compensation 25 °C || +/- 4.6 °C thermocouple E with internal cold-junction compensation 25 °C || +/- 5 °C thermocouple S with internal cold-junction compensation 60 °C || +/- 5.1 °C thermocouple J with internal cold-junction compensation 25 °C || +/- 5.5 °C thermocouple K with internal cold-junction compensation 60 °C || +/- 6.4 °C thermocouple T with internal cold-junction compensation 60 °C || +/- 6.8 °C thermocouple B with internal cold-junction compensation 60 °C || +/- 6.8 °C thermocouple E with internal cold-junction compensation 60 °C || +/- 7 °C thermocouple J with internal cold-junction compensation 60 °C || +/- 1 °C Ni 1000 25 °C internal || +/- 1 °C Pt 100 25 °C internal || +/- 1 °C Pt 1000 25 °C internal || +/- 1.75 °C thermocouple B with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple E with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple J with external cold-junction compensation 25 °C |
Measurement Resolution | 0.01 mV voltage || 0.1 °C or 0.1 °F temperature probe || 0.1 °C or 0.1 °F thermocouple |
Maximum Supply Current For Sensors | 100 mA per input channels |
Input Impedance | 10 MOhm +/- 80 mV |
Status Led | 1 LED (Green) module status (RDY) || 1 LED (Red) module error (ERR) |
Hot Swapping Fallback | yes for standard NIMs |
Supply | power distribution module |
Data Format | EN 61131-2 || IEC 61131-2 |
Current Consumption | 30 mA 5 V DC logic bus |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1511012EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Circularity Profile | ENVEOLI1511012EN |
Environment | |
Product Certifications | UL || FM Class 1 Division 2 || CSA || ATEX Cat 3G || C-tick |
Operating Altitude | <= 6561.68 ft (2000 m) |
Ambient Air Temperature For Operation | 32...140 °F without derating |
Ambient Air Temperature For Storage | -40...185 °F without derating |
Ambient Air Temperature For Operation | 0-70 °C |
Shock Resistance | 30 gn 11 ms IEC 88 reference 2-27 |
Vibration Resistance | +/-0.35 mm 10-58 Hz || 3 gn 58-150 Hz 35 x 7.5 mm symmetrical DIN rail || 5 gn 58-150 Hz 35 x 15 mm symmetrical DIN rail |
Ip Degree Of Protection | IP20 conforming to EN 61131-2 class 1 |
Pollution Degree | 2 IEC 60664-1 |
Ambient Air Temperature For Storage | -40-85 °C without derating |
Relative Humidity | 95-95 % 60-60 °C without condensation |