Pendant control station, Harmony XAC, plastic, yellow, 2 push buttons with NO+NC, 1 emergency stop NC
- Produttore:
- Schneider Electric
This Schneider Electric Harmony XAC yellow pendant station for hoist motor has single speed. It has 1 "raise" + 1 "lower" + 1 emergency stop push-buttons and uses screw-clamp terminals. This pendant station for hoist motor is designed for standard or medium-duty control circuit applications in your machines. It has 2 push-buttons and 1 emergency stop with "raise" and "lower" markings, with normally open and normally close contact. It is impact resistant (strength), dust resistant (strength), water resistant (strength) and vibration resistant (strength) thanks to its IP65, making it ideal for operation in harsh (heavy) environments. Impact- and stain resistant (strength) enclosure for a sustained appearance despite rough usage conditions. No need to damage your machine or system with multiple 22mm hole, thus avoiding common issues like edge corrosion. Yellow enclosure, favoring visual contrast and visibility in dark conditions. Wide range of operating temperatures from -25°C to 70°C allows versatility in usage of product. Vibration resistant screw clamp connection terminals ensure high vibration resistance making product suitable installation on high impact machine.
Specifications
Certifications | CCC |
---|---|
Enclosure Material | Polypropylene |
Net Weight | 0.6 kg |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Specifications | |
Range Of Product | Harmony XAC |
Product Or Component Type | pendant control station |
Device Short Name | XACA |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Product Certifications | GOST || CCC |
Short-Circuit Protection | 10 A fuse protection cartridge gG |
Cable Entry | rubber sleeve with stepped entry 8-26 mm |
Shock Resistance | 100 gn IEC 60068-2-27 |
Enclosure Type | complete ready for use |
Vibration Resistance | 15 gn 10-500 Hz)IEC 60068-2-6 |
Net Weight | 0.6 kg |
Product Compatibility | ZB2BE102 for emergency stop || ZB2BE102 + ZB2BE101 for each direction |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-1 |
Ip Degree Of Protection | IP65 conforming to IEC 60529 |
Control Station Type | double insulated |
Ik Degree Of Protection | IK08 EN 50102 |
Connections - Terminals | screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end || screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end |
[Ui] Rated Insulation Voltage | 600 V 3) |
Ambient Air Temperature For Storage | -40-70 °C |
Control Station Composition | 2 push-buttons + 1 emergency stop |
Overvoltage Category | class II IEC 61140 |
Contact Operation | slow-break |
Mechanical Interlocking | with mechanical interlocking |
Control Station Colour | yellow |
Mechanical Durability | 1000000 cycles |
Operating Force | 13-13 N push-button || 8-8 N emergency stop |
Control Station Application | control of single speed hoist motor |
Control Button Type | stop push-button Ø 30 mm 1 NC latching || first push-button 1 NC + 1 NO raise, slow || second push-button 1 NC + 1 NO lower, slow |
[Ithe] Conventional Enclosed Thermal Current | 10 A |
Electrical Circuit Type | control circuit |
Enclosure Material | polypropylene |
Contact Code Designation | A600 AC-15, Ue = 240 V, Ie = 3 A IEC 60947-5-1 appendix A || A600 AC-15, Ue = 600 V, Ie = 1.2 A IEC 60947-5-1 appendix A || Q600 DC-13, Ue = 250 V, Ie = 0.27 A IEC 60947-5-1 appendix A || Q600 DC-13, Ue = 600 V, Ie = 0.1 A IEC 60947-5-1 appendix A |
Protective Treatment | TH |
Rated Operational Power In W | 40 W DC-13 1000000 cycles 60 cyc/mn 120 V 0.5 inductive IEC 60947-5-1 appendix C || 48 W DC-13 1000000 cycles 60 cyc/mn 48 V 0.5 inductive IEC 60947-5-1 appendix C || 65 W DC-13 1000000 cycles 60 cyc/mn 24 V 0.5 inductive IEC 60947-5-1 appendix C |
Terminal Identifier | (11-12)NC || (13-14)NO |
Ambient Air Temperature For Operation | -25-70 °C |
Terminals Description Iso N°2 | (11-12)NC |
Terminals Description Iso N°1 | (11-12)NC || (13-14)NO |
Standards | EN/IEC 60947-5-1 || CSA C22.2 No 14 || UL 508 || EN/IEC 60204-32 |
Maximum Resistance Across Terminals | 25 MOhm |
Offer Sustainability | |
Rohs Exemption Information | Yes |
China Rohs Regulation | X |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP070905EN |
Sustainable Offer Status | Green Premium product |
Toxic Heavy Metal Free | Yes |
Reach Regulation | Free of Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Reach Free Of Svhc | Yes |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |