Harmony XB4, Key switch selector, metal, black, Ø22, key 455, 2 positions, stay put, 1 NO

Produttore:
Schneider Electric
Schneider electric

7e2b1023f4cc9c4d30bd3b3bc571e27a2fd0785f medium
Prezzo (IVA esclusa)
€ 37.56
Codice Nuova Elva
XB4BG21
Codice produttore
XB4BG21
Disponibilità
13 in stock

This Harmony XB4 modular black key selector switch (key no.455) has 2 positions, operates with a stay-put mechanism with key withdrawal on the left position. It has a metal bezel. This key selector switch provides a versatile interface for controlling your machines. It is easily installed into standard 22mm diameter cut-outs and connected to your control circuits with simple screw-clamp connections. It provides a secure manner for authorized staff to switch between process or machine operating modes. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP66 / IP67 / IP69 / IP69K, making it ideal for operation in harsh environments.

Specifications

Bezel MaterialChromium Plated Metal
CertificationsBV
Contact MaterialSilver Alloy
Depth86 mm
Height47 mm
Net Weight0.117 kg
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width30 mm

Specifications

Range Of ProductHarmony XB4
Sale Per Indivisible Quantity1
Bezel Materialchromium plated metal
Contact Operationslow-break
Operator Profilekey switch
Operator Position Information2 positions 90°
Device Short NameXB4
Mounting Diameter22 mm
Type Of Operatorstay put
Product Or Component Typeselector switch
Shape Of Signaling Unit Headround
Fixing Collar Materialzamak
Head Typestandard
Connections - Terminalsscrew clamp terminals, <= 2 x 1.5 mm² with cable end EN/IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end EN/IEC 60947-1
Contacts Type And Composition1 NO

Contractual warranty

Warranty18 months

Complementary

Contacts Usagestandard contacts
Device Presentationcomplete product
Resistance To High Pressure Washer7000000 Pa 55 °C 0.1 m
Electrical Durability1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN 60947-5-1 appendix C
Key Withdrawal Positionleft-hand
[Ui] Rated Insulation Voltage600 V 3)EN 60947-1
[Ie] Rated Operational Current3 A 240 V, AC-15, A600 EN/IEC 60947-5-1 || 6 A 120 V, AC-15, A600 EN/IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1
Mechanical Durability1000000 cycles
Torque Value0.14 N.m NO changing electrical state
Electrical Reliabilityλ < 10exp(-6) 5 V 1 mA in clean environment EN/IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA in clean environment EN/IEC 60947-5-4
Width30 mm
Height47 mm
Depth86 mm
Tightening Torque0.8-1.2 N.m EN 60947-1
Shape Of Screw Headcross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm
Type Of Keylockkey 455
Terminals Description Iso N°1(13-14)NO
Short-Circuit Protection10 A cartridge fuse gG EN/IEC 60947-5-1
Contacts Materialsilver alloy (Ag/Ni)
Positive Openingwithout
[Ith] Conventional Free Air Thermal Current10 A EN/IEC 60947-5-1
Net Weight0.117 kg
[Uimp] Rated Impulse Withstand Voltage6 kV EN 60947-1

Offer Sustainability

Rohs Exemption InformationYes
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Mercury FreeYes
Environmental DisclosureENVPEP1808008EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationX
Circularity ProfileENVEOLI1808008EN

Environment

Product CertificationsUL || BV || DNV || CSA || GL || LROS (Lloyds register of shipping)
Ik Degree Of ProtectionIK06 with keyhole cover ZBGP conforming to IEC 50102
Protective TreatmentTH
Ambient Air Temperature For Operation-40-70 °C
StandardsJIS C8201-5-1 || EN/IEC 60947-5-5 || EN/IEC 60947-1 || UL 508 || EN/IEC 60947-5-4 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || JIS C8201-1
Shock Resistance30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Vibration Resistance5 gn 2-500 Hz)IEC 60068-2-6
Ip Degree Of ProtectionIP66 IEC 60529 || IP69 || IP69K || IP67
Ambient Air Temperature For Storage-40-70 °C
Overvoltage Categoryclass I IEC 60536
Nema Degree Of ProtectionNEMA 13 || NEMA 4X

Documentazione