Limit switch, Limit switches XC Standard, XC2 J, roller lever, 1 C/O
- Produttore:
- Schneider Electric
- Prezzo (IVA esclusa)
- € 135.58
- Codice Nuova Elva
- XC2JC10131
- Codice produttore
- XC2JC10131
- Disponibilità
- Invia RdO
This product is part of the XC Special range, an offer of limit switches. This limit switch is a device that converts a mechanical motion into an electrical control signal. It has 1 change over, snap action contact without positive opening operation and provides switch actuation by 30° cam. It has a lateral approach in 2 directions. The movement of limit switch operating head is rotary. It is furnished with screw clamp terminals for electrical connection and 1 entry incorporating cable gland. It is an IP65, IP67 and IK08 rated product. It has a rated operational current of 3A at 240V AC, 0.27A at 250V AC and a conventional enclosed thermal current of 10A. Its mechanical durability is 30 million operating cycles and electrical durability is 5 million operating cycles. This limit switch has a fixed type body which is made of metal. Its dimensions are 40mm (Width) x 65mm (Depth) x 222mm (Height) and weighs 0.605kg. It is suitable for severe applications. This product is certified by CSA, NEMKO and DEMKO. It meets VDE 0660-200, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 and IEC 60337-1 standards. Special format limit switches for severe environments.
Specifications
Certifications | CSA |
---|---|
Contact Material | Silver Plated Contacts |
Depth | 65 mm |
Height | 222-222 mm |
Material | Metal |
Net Weight | 0.605 kg |
Number of Poles | 1 |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Width | 40 mm |
Specifications | |
Movement Of Operating Head | rotary |
Body Type | fixed |
Contact Operation | snap action |
Product Specific Application | for severe applications |
Maximum Actuation Speed | 1.5 m/s |
Minimum Torque For Tripping | 0.3 N.m |
Device Short Name | XC2J |
Number Of Poles | 1 |
Range Of Product | OsiSense XC |
Type Of Operator | roller lever thermoplastic variable length |
Product Or Component Type | limit switch |
Material | metal |
Head Type | rotary head |
Switch Actuation | by 30° cam |
Type Of Approach | lateral approach, 2 directions |
Series Name | special format |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Height | 222-222 mm |
[Ui] Rated Insulation Voltage | 500 VIEC 60947-5-1 || 500 VNF C 20-040 group C || 300 VCSA C22.2 No 14 |
Electrical Durability | 5000000 cycles, DC-13, 120 V, 4 W 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 24 V, 10 W 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 7 W 3600 cyc/h 0.5 IEC 60947-5-1 appendix C |
Positive Opening | without |
Contacts Insulation Form | Za |
Mechanical Durability | 30000000 cycles |
Contact Code Designation | A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 |
Width | 40 mm |
Depth | 65 mm |
Maximum Resistance Across Terminals | 25 MOhm IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A |
Terminals Description Iso N°1 | (13-14-11-12)OF |
Short-Circuit Protection | 10 A cartridge fuse gG |
Minimum Actuation Speed | 0.001 m/min |
Electrical Connection | screw-clamp terminals 1 x 0.5...2 x 2.5 mm² |
Fixing Mode | by the body |
Contacts Material | silver plated contacts |
Cable Entry | 1 entry incorporating cable gland 6-13.5 mm |
Net Weight | 0.605 kg |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP110614EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Product Certifications | NEMKO || DEMKO || CSA |
Protective Treatment | TC |
Ik Degree Of Protection | IK08 |
Ambient Air Temperature For Operation | -25-70 °C |
Standards | VDE 0660-200 || EN/IEC 60947-5-1 || UL 508 || CSA C22.2 No 14 || IEC 60337-1 |
Shock Resistance | 25 gn 18 ms IEC 60068-2-27 |
Vibration Resistance | 10 gn 10-500 Hz)IEC 60068-2-6 |
Ip Degree Of Protection | IP65 conforming to IEC 60529 || IP657 conforming to NF C 20-010 |
Ambient Air Temperature For Storage | -40-70 °C |
Electrical Shock Protection Class | class I IEC 60536 || class I NF C 20-030 |